{"id":1023,"date":"2026-09-17T12:52:18","date_gmt":"2026-09-17T04:52:18","guid":{"rendered":"https:\/\/brt-testing.com\/?post_type=product&#038;p=1023"},"modified":"2026-09-23T14:12:51","modified_gmt":"2026-09-23T06:12:51","slug":"brt-5000uv-uv-vis-spectrophotometer","status":"publish","type":"product","link":"https:\/\/brt-testing.com\/de\/product\/brt-5000uv-uv-vis-spectrophotometer\/","title":{"rendered":"BRT-5000UV High Precision UV\/Vis Spectrophotometer"},"content":{"rendered":"<p><!-- 1. Executive Summary & Value Proposition --><\/p>\n<p>The <strong>BRT-5000UV High Precision UV\/Vis Spectrophotometer<\/strong> is an advanced single-beam laboratory analytical instrument engineered strictly for high-accuracy photometric, quantitative, and concentration analysis. Designed for chemical research facilities, environmental testing centers, pharmaceutical quality control labs, and academic institutions, it delivers precise spectral characterization across the 200 nm to 1000 nm optical spectrum with a 4 nm bandwidth and 0.1 nm resolution.<\/p>\n<p>Featuring a high-performance Czerny-Turner (C-T) monochromator paired with a 1200 lines\/mm holographic grating, a high-sensitivity silicon photocell, and long-life dual tungsten and deuterium lamps, this high-precision <strong>UV-Vis Spectrophotometer<\/strong> ensures exceptional stray light suppression and baseline stability. Equipped with a 4.3-inch color LCD touch screen, automated wavelength calibration, onboard 200-set curve memory, and USB PC software connectivity, the BRT-5000UV streamlines routine laboratory workflows.<\/p>\n<hr \/>\n<p><!-- 2. Applicable Measurement Modes & Methodologies --><\/p>\n<h3>UV-Vis Spectrophotometer Measurement &amp; Analysis Capabilities<\/h3>\n<p>This analytical optical spectrometer enables certified laboratories to conduct standardized quantitative, photometric, and concentration determinations across diverse sample matrices:<\/p>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr style=\"background-color: #f8f9fa;\">\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Analysis Mode<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Methodology &amp; Operational Scope<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Primary Testing Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Photometric Measurement<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Direct evaluation of Transmittance (%T) and Absorbance (Abs) at single or multiple fixed wavelengths<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Rapid purity checks, optical density evaluation, and baseline transmittance testing<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Quantitative Concentration (C\/F Method)<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Multi-point standard sample calibration curve fitting and linear factor (C = K \u00d7 Abs + B) determination<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Chemical concentration profiling, environmental pollutant quantification, and bio-assays<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Kinetic &amp; Spectral Analysis (via PC)<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Time-course reaction kinetics, full spectral scanning, and multi-wavelength measurements using PC software<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Enzyme reaction rate monitoring, dye degradation studies, and material absorption profiling<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 3. Key Technological Advantages --><\/p>\n<h3>Technological Features of BRT-5000UV UV-Vis Spectrophotometer<\/h3>\n<ul>\n<li><strong>Czerny-Turner (C-T) Monochromator &amp; 1200 L\/mm Grating<\/strong>Combines a high-efficiency C-T optical pathway with a 1200 lines\/mm holographic grating to suppress stray light and guarantee linear photometric response across the full spectral range.<\/li>\n<li><strong>4.3-Inch Color Touch Screen Interface<\/strong>Provides simultaneous display of Transmittance (%T), Absorbance (Abs), Concentration (C), and Factor (F) with a 0.1 nm resolution readout and user-friendly touch navigation.<\/li>\n<li><strong>Automated Startup Self-Testing &amp; Baseline Balance<\/strong>Performs automatic wavelength calibration, zero-absorbance (0A), and 100% transmittance (100%T) baseline setup upon startup, drastically reducing manual preparation time.<\/li>\n<li><strong>Dual Light Source Management (Tungsten &amp; Deuterium)<\/strong>Includes independently controlled halogen tungsten and imported deuterium lamps with automatic light source switching based on the operating spectral domain.<\/li>\n<li><strong>Versatile 5 mm\u2013100 mm Cuvette Accommodations<\/strong>Features a spacious internal sample compartment compatible with cuvette holders ranging from 5 mm to 100 mm pathlengths for low-concentration or high-turbidity sample testing.<\/li>\n<li><strong>Onboard Storage &amp; Flexible Data Export<\/strong>Stores up to 200 standard curves and data sets internally; includes a USB port for PC software expansion and a parallel printer port for direct desktop printing.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 4. Technical Specifications --><\/p>\n<h3>Technical Specifications of UV-Vis Spectrophotometer<\/h3>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px; width: 35%;\"><strong>Product Model<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">BRT-5000UV High Precision UV\/Vis Spectrophotometer<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Optical System Design<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Single Beam, Czerny-Turner (C-T) Monochromator (1200 lines\/mm Grating)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Wavelength Spectrum &amp; Bandwidth<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">200 nm to 1000 nm; Spectral Bandwidth: 4 nm; Resolution: 0.1 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Wavelength Accuracy &amp; Repeatability<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Accuracy: \u00b12 nm; Repeatability: \u22641 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Photometric Range &amp; Transmittance Accuracy<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">0 to 200%T, -0.301 to 3.000 Abs, -9999 to 9999 C; Transmittance Accuracy: \u00b10.3%T<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Light Sources &amp; Detector<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Tungsten Halogen Lamp &amp; Imported Deuterium Lamp; High-Sensitivity Silicon Photocell<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Display &amp; Memory<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">4.3-inch Color Touch Screen; Internal storage for 200 data sets &amp; calibration curves<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Dimensions &amp; Weight<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">470 \u00d7 380 \u00d7 225 mm (W \u00d7 D \u00d7 H); Weight: 10.5 kg; Universal Power Supply<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 5. System Configuration & Package Components --><\/p>\n<h3>Standard Package Accessories Included<\/h3>\n<ul>\n<li><strong>Host Instrument:<\/strong> BRT-5000UV Main UV-Vis Spectrophotometer Unit (1 unit).<\/li>\n<li><strong>Optical Cuvettes:<\/strong> 10 mm Standard Quartz Cuvettes (2 pcs for UV range), 10 mm Standard Glass Cuvettes (4 pcs for Visible range).<\/li>\n<li><strong>Power &amp; Interface Cables:<\/strong> AC Power Cord (1 pc), USB Interconnect Cable (1 pc).<\/li>\n<li><strong>Documentation &amp; Software:<\/strong> Operating Instruction Manual, Certificate of Conformity, Warranty Card.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 6. Applications & Testing Workflow --><\/p>\n<h3>Testing Workflow &amp; Target Applications<\/h3>\n<p><strong>Standardized Testing Workflow:<\/strong><\/p>\n<ol>\n<li>Power on the BRT-5000UV; the system automatically initiates self-testing, wavelength calibration, and baseline balance adjustments.<\/li>\n<li>Select the desired operating mode (Photometric, Quantitative, or Concentration) on the 4.3-inch color touch screen.<\/li>\n<li>Place a reference blank cuvette into the sample compartment to zero the instrument (0A and 100%T balance).<\/li>\n<li>Insert the sample cuvette into the optical path, measure absorbance or transmittance values, or fit standard sample concentration curves.<\/li>\n<li>Save results into internal memory (up to 200 data sets) or export data directly to PC software via USB for advanced reporting.<\/li>\n<\/ol>\n<p><iframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/WpVaZXW3bcY?si=iBnXVC_HCVxnUJGl\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p><iframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/4dOX_pD6hY4?si=19Cik1XKDphoUfaD\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p><strong>Target Customer Applications:<\/strong><\/p>\n<ul>\n<li>Environmental water quality analysis centers (COD, nitrate, phosphate, and heavy metal detection).<\/li>\n<li>Pharmaceutical quality control facilities and life science analytical laboratories.<\/li>\n<li>Chemical processing plants, petrochemical QA bays, and textile dye inspection stations.<\/li>\n<li>University chemistry departments and food &amp; beverage safety testing labs.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 7. Frequently Asked Questions (FAQ) --><\/p>\n<h3>UV-Vis Spectrophotometer FAQ<\/h3>\n<h4>Q1: What pathlength cuvettes can be used with the BRT-5000UV?<\/h4>\n<p><strong>A:<\/strong> The standard sample compartment is designed to accommodate cuvettes with optical pathlengths ranging from 5 mm up to 100 mm, allowing analysis of both low-concentration and high-turbidity samples.<\/p>\n<h4>Q2: Does the instrument require manual wavelength calibration upon startup?<\/h4>\n<p><strong>A:<\/strong> No. The BRT-5000UV features automatic self-testing and wavelength calibration upon powering on, alongside automatic 0A and 100%T baseline calibration.<\/p>\n<h4>Q3: Why are quartz cuvettes required for ultraviolet (UV) measurements?<\/h4>\n<p><strong>A:<\/strong> Standard glass cuvettes absorb ultraviolet light below 340 nm, interfering with sample readings. Quartz cuvettes are optically transparent across both UV (200\u2013340 nm) and Visible (340\u20131000 nm) spectrums.<\/p>","protected":false},"excerpt":{"rendered":"<p><b data-path-to-node=\"7,0\" data-index-in-node=\"0\">BRT-5000UV High Precision UV\/Vis Spectrophotometer<\/b> is a single-beam laboratory analytical system featuring a Czerny-Turner (C-T) monochromator, 1200 lines\/mm holographic grating, 200\u20131000 nm spectral range, and 4 nm bandwidth. Equipped with a 4.3-inch touch screen, dual tungsten\/deuterium lamps, automated calibration, 5 mm\u2013100 mm cuvette chamber, and 200-set curve memory for chemical and environmental QA.<\/p>","protected":false},"featured_media":1024,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[117],"product_cat":[21],"product_tag":[],"class_list":["post-1023","product","type-product","status-publish","has-post-thumbnail","product_brand-brt-testing","product_cat-uv-vis-spectrophotometer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product\/1023","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/comments?post=1023"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/media\/1024"}],"wp:attachment":[{"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/media?parent=1023"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product_brand?post=1023"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product_cat?post=1023"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product_tag?post=1023"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}