{"id":724,"date":"2026-09-11T17:00:10","date_gmt":"2026-09-11T09:00:10","guid":{"rendered":"https:\/\/brt-testing.com\/?post_type=product&#038;p=724"},"modified":"2026-09-23T14:15:43","modified_gmt":"2026-09-23T06:15:43","slug":"intelligent-automatic-touch-screen-oxygen-index-tester","status":"publish","type":"product","link":"https:\/\/brt-testing.com\/de\/product\/intelligent-automatic-touch-screen-oxygen-index-tester\/","title":{"rendered":"JYZS-20 Intelligent Automatic Touch Screen Oxygen Index Tester"},"content":{"rendered":"<p><!-- 1. Executive Summary & Value Proposition --><\/p>\n<p>The <strong>JYZS-20 Fully Automatic Oxygen Index Tester<\/strong> is a top-tier, touch-screen-controlled flammability testing system designed to determine the Limiting Oxygen Index (LOI \/ OI) of polymers, plastics, textiles, rubber, and building components. Engineered in strict compliance with <strong>ISO 4589-2<\/strong>, <strong>ASTM D2863<\/strong>, <strong>BS 2782-1 (Method 141)<\/strong>, <strong>NES 715<\/strong>, and national standards <strong>GB\/T 2406<\/strong> and <strong>GB\/T 5454<\/strong>, this apparatus provides automated gas mixing without manual needle-valve tweaking.<\/p>\n<p>Featuring a stepper-driven proportional valve with closed-loop concentration correction, an imported high-precision oxygen sensor (0\u2013100% range, \u00b10.1% resolution), a standard 500 mm \u00d7 \u226575 mm glass combustion column, and automated 40 \u00b1 2 mm\/s gas flow velocity control, this advanced <strong>Automated Limiting Oxygen Index (LOI) Apparatus<\/strong> eliminates measurement drift and ensures uncompromised data integrity for polymer producers, cable manufacturers, and third-party testing laboratories.<\/p>\n<hr \/>\n<p><!-- 2. Applicable Standards & Test Classifications --><\/p>\n<h3>Fully Automatic Oxygen Index Tester Compliance &amp; Standards<\/h3>\n<p>This closed-loop automated LOI testing system enables accredited laboratories to perform formal limiting oxygen index evaluations across global standards:<\/p>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr style=\"background-color: #f8f9fa;\">\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Standard Code<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Standard Title &amp; Scope<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Primary Testing Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>ISO 4589-2<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Plastics \u2014 Determination of burning behaviour by oxygen index \u2014 Part 2: Ambient-temperature test<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">International benchmark method for evaluating the flammability of rigid and flexible polymers at room temperature<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>ASTM D2863<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Standard test method for measuring the minimum oxygen concentration to support candle-like combustion of plastics<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">North American standard for determining oxygen index across plastic resins, insulating compounds, and films<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>BS 2782-1 (Method 141) &amp; NES 715<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Methods of testing plastics \u2014 Oxygen index &amp; Naval Engineering Standard for material flammability<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">British and military-grade qualification for defense, naval vessel interior materials, and industrial plastics<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>GB\/T 2406 &amp; GB\/T 5454<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Plastics and Textiles \u2014 Determination of burning behaviour by oxygen index<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Mandatory Chinese national standards for plastic sheet, cellular foam, cable jacketing, and textile flame retardancy<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 3. Key Technological Advantages --><\/p>\n<h3>Technological Features of JYZS-20 Automatic LOI Tester<\/h3>\n<ul>\n<li><strong>Closed-Loop Automatic Concentration &amp; Flow Control:<\/strong> Touchscreen input instantly commands a stepper-driven proportional valve to adjust O\u2082\/N\u2082 ratios. The system automatically corrects real-time oxygen drift during combustion.<\/li>\n<li><strong>High-Precision Imported Oxygen Sensor:<\/strong> Direct digital display of O\u2082 percentage with \u00b10.1% resolution and fast response time (&lt;5 s), eliminating complex manual calculations.<\/li>\n<li><strong>Standardized Column Flow &amp; Velocity Dynamics:<\/strong> Maintains a constant gas velocity of 40 \u00b1 2 mm\/s inside the 500 mm (H) \u00d7 \u226575 mm (ID) glass combustion column across 0\u201320 L\/min flow ranges.<\/li>\n<li><strong>Versatile Dual Specimen Mounting Systems:<\/strong> Includes both self-supporting rigid clamps (for thick plastics, boards, and timber) and non-self-supporting frame clamps (for thin films, flexible foams, and textiles).<\/li>\n<li><strong>Precision Propane\/Butane Ignition System:<\/strong> Fitted with an \u00d82 \u00b1 1 mm metal burner nozzle capable of delivering an adjustable 5 mm to 60 mm ignition flame (standard setting: 16 \u00b1 4 mm).<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 4. Technical Specifications --><\/p>\n<h3>Technical Specifications of JYZS-20 Automatic Oxygen Index Tester<\/h3>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px; width: 35%;\"><strong>Governing Test Standards<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">ISO 4589-2, ASTM D2863, BS 2782-1, NES 715, GB\/T 2406, GB\/T 5454<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Oxygen Concentration Measurement Range<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">0 to 100% O\u2082; Resolution: \u00b10.1%; Response time: &lt;5 s<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Glass Combustion Column Dimensions<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Internal diameter \u2265 75 mm; Height: 500 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Gas Flow Velocity in Column<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">40 \u00b1 2 mm\/s; Total flow adjustment: 0\u201320 L\/min (0\u20131200 L\/h)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Igniter Nozzle &amp; Flame Geometry<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Nozzle inner diameter: \u00d82 \u00b1 1 mm; Flame length: 16 \u00b1 4 mm (adjustable 5\u201360 mm)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Required Gas Supply (User-Provided)<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Gaseous O\u2082 and N\u2082 (purity &gt;99%); Cylinder pressure regulators: 0.2 MPa; Operating inlet pressure: 0.1\u20130.15 MPa<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Specimen Clamping Options<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Self-supporting clamp (rigid samples) &amp; Non-self-supporting frame (flexible\/textile samples)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Operating Conditions &amp; Power<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Ambient temp: -10 \u00b0C to 45 \u00b0C; RH &lt;85%; AC 220 V \u00b1 10%, 50 Hz, 100 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 5. Applications & Workflow --><\/p>\n<h3>System Architecture &amp; Testing Workflow of JYZS-20 Oxygen Index Tester<\/h3>\n<p><strong>Standardized Testing Workflow:<\/strong><\/p>\n<ol>\n<li>Mount the rigid or flexible specimen into the designated holder and position it vertically along the axis of the combustion column.<\/li>\n<li>Select the target oxygen concentration (e.g., 21.0%) on the full-color touchscreen.<\/li>\n<li>The closed-loop system automatically modulates the proportional valve to adjust O\u2082\/N\u2082 mixing until flow stabilizes at 40 \u00b1 2 mm\/s.<\/li>\n<li>Ignite the propane igniter (flame length 16 \u00b1 4 mm) and insert it from the top of the column to ignite the upper tip of the specimen.<\/li>\n<li>Observe flame propagation and burning time; step the oxygen concentration up or down until the precise Limiting Oxygen Index (LOI) threshold is established.<\/li>\n<\/ol>\n<p><strong>Target Customer Applications:<\/strong><\/p>\n<ul>\n<li>Polymer resin manufacturers, masterbatch formulators, and compounders (PP, ABS, PVC, PE, PU).<\/li>\n<li>Wire and cable jacketing, electrical insulation, and connector component manufacturers.<\/li>\n<li>Flame-retardant textile mills, technical fabrics, and protective garment testing centers.<\/li>\n<li>Third-party fire research institutes and ISO 17025 certified testing laboratories.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 6. Frequently Asked Questions (FAQ) --><\/p>\n<h3>JYZS-20 Fully Automatic Oxygen Index Tester FAQ<\/h3>\n<h4>Q1: What is the main advantage of a fully automatic oxygen index tester over conventional manual models?<\/h4>\n<p><strong>A:<\/strong> Traditional testers require manual tweaking of rotor flowmeters or needle valves, which causes drift during combustion. The JYZS-20 utilizes a stepper-driven proportional valve and closed-loop control to automatically maintain exact target oxygen concentrations and column gas velocity without manual intervention.<\/p>\n<h4>Q2: What is Limiting Oxygen Index (LOI) and why is it important?<\/h4>\n<p><strong>A:<\/strong> LOI represents the minimum concentration of oxygen in an oxygen\/nitrogen mixture that will support candle-like combustion of a material. Since ambient air contains ~20.9% oxygen, materials with an LOI &gt; 21% are harder to ignite in air, and materials with an LOI &gt; 28% are considered flame-retardant.<\/p>\n<h4>Q3: Can this device test both rigid plastics and soft fabrics or thin films?<\/h4>\n<p><strong>A:<\/strong> Yes. The JYZS-20 includes two specialized holders: a self-supporting clamp for rigid plastics\/boards and a non-self-supporting frame clamp for thin films, flexible foams, and textiles.<\/p>","protected":false},"excerpt":{"rendered":"<p><b data-path-to-node=\"7,0\" data-index-in-node=\"0\">JYZS-20 Oxygen Index Tester<\/b> strictly complies with ISO 4589-2, ASTM D2863, BS 2782-1, NES 715, GB\/T 2406, GB\/T 5454 standards. Features automated touchscreen gas regulation, closed-loop concentration correction (\u00b10.1% accuracy), an imported 0\u2013100% oxygen sensor (&lt;5s response), dual specimen holders for rigid\/flexible polymers, and a 40\u00b12mm\/s airflow combustion column for precise Limiting Oxygen Index (LOI) testing.<\/p>","protected":false},"featured_media":726,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[117],"product_cat":[24],"product_tag":[],"class_list":["post-724","product","type-product","status-publish","has-post-thumbnail","product_brand-brt-testing","product_cat-fire-flame-testing-equipment","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product\/724","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/comments?post=724"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/media\/726"}],"wp:attachment":[{"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/media?parent=724"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product_brand?post=724"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product_cat?post=724"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/brt-testing.com\/de\/wp-json\/wp\/v2\/product_tag?post=724"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}