BRT-1200UV UV Vis Spectrophotometer is a benchtop single-beam instrument featuring a 200–1000 nm spectral range, 4 ancho de banda nm, 1200 líneas/mm rejilla holográfica, and ≤0.5 nm wavelength repeatability. Equipped with dual tungsten/deuterium lamps, an LCD display, 9-sample curve fitting, 200-dataset memory, USB PC connectivity, and LPT printer output, it provides precise photometric and quantitative chemical testing.

SKU: BRT-1200UV, Categorías: ,
Consulta ahora

DIRECCIÓN DE CORREO ELECTRÓNICO

NOMBRE DE PILA

APELLIDO

WhatsApp

MENSAJE

El BRT-1200UV UV Vis Spectrophotometer is a high-precision benchtop analytical instrument engineered for multi-mode quantitative chemical analysis, optical absorbance screening, and quality control. Designed for environmental monitoring stations, pharmaceutical QA/QC laboratories, biochemical research facilities, and university chemistry departments, it delivers stable spectral performance across the 200 nm a 1000 espectro óptico nm con un 4 nm spectral bandwidth, ±2 nm wavelength accuracy, and ≤0.5 nm wavelength repeatability.

Built with a high-performance single-beam optical system featuring a 1200 líneas/mm rejilla holográfica, a high-sensitivity photocell detector, and independently managed tungsten halogen and imported deuterium lamps, this versatile Espectrofotómetro UV-VIS guarantees superior photometric accuracy (±0,3%T) and reliable quantitative linearity. Equipped with an LCD display, onboard memory for 200 datasets and 9-point linear regression curves, USB connection for PC software, and a parallel printer interface, the BRT-1200UV optimizes routine laboratory testing workflows.


UV Vis Spectrophotometer Measurement & Capacidades de análisis

This benchtop single-beam spectrophotometer enables laboratory operators to conduct certified photometric, cuantitativo, and kinetic testing routines across liquid and solution samples:

Modo de análisis Metodología & Alcance Operativo Solicitud de prueba primaria
Medición fotométrica Evaluación directa de Transmitancia (%t) y absorbancia (abdominales) at user-specified fixed wavelengths Routine sample clarity verification, optical density checks, and basic QA transmittance testing
Multi-Point Quantitative Curve Fitting Quantitative concentration profiling using single-point factor method or multi-point calibration fitting up to 9 standard samples with automatic regression calculations Perfiles de concentración química, pharmaceutical active ingredient quantification, and environmental water pollutant assays
PC-Driven Kinetics & Análisis espectral Time-course enzyme kinetics, multi-wavelength testing, and full-spectrum scanning via optional professional PC software interface Enzyme reaction kinetics, thermal degradation monitoring, and complex multi-component sample evaluation

Technological Features of BRT-1200UV UV Vis Spectrophotometer

  • Single-Beam Optics with 1200 L/mm Holographic GratingFeatures an advanced optical path with a 1200 lines/mm holographic grating and silicon photocell detector to deliver sharp optical resolution and high signal purity.
  • High Repeatability (≤0.5 nm) & 0.1 nm Resolution DisplayDelivers tight wavelength repeatability (≤0.5 nm) con un 0.1 nm resolution digital readout for consistent baseline stability across repeated measurements.
  • Automated Zeroing & Lamp SwitchingIncorporate automatic wavelength positioning, automatic 0A and 100%T calibration, and independent microcomputer control for tungsten and deuterium lamp management.
  • Multi-Point Curve Fitting & Onboard MemoryAlmacena hasta 200 datasets and regression standard curves generated from up to 9 standard samples directly on the unit without requiring active PC connection.
  • Spacious Sample Chamber (5 mm a 100 mm Pathlength)Accommodates cell holders for cuvettes ranging from 5 mm hasta 100 mm pathlengths, facilitating both high-concentration and dilute sample analysis.
  • Dual Communications Interface (USB & LPT)Equipped with a USB port for bidirectional PC software data management and a parallel port (LPT) for direct printing to dedicated laboratory printers.

Technical Specifications of UV Vis Spectrophotometer

Modelo de producto BRT-1200UV Benchtop UV Vis Spectrophotometer
Optical System & Grating Haz único, 1200 lines/mm Holographic Grating
Espectro de longitud de onda & Ancho de banda 200 nm a 1000 Nuevo Méjico; Ancho de banda espectral: 4 Nuevo Méjico; Wavelength Resolution: 0.1 Nuevo Méjico
Precisión de longitud de onda & Repetibilidad Exactitud: ±2 nm; Repetibilidad: ≤0.5 nm
Rango fotométrico & Exactitud 0 al 200%T, -0.301 a 3.000 abdominales, -9999 a 9999 do; Precisión de transmitancia: ±0,3%T
Fuentes de luz & Detector Lámpara halógena de tungsteno & Lámpara de deuterio importada; Fotocélula de silicio de alta sensibilidad
Data Ports & Storage USB Interface (PC Software Compatible), LPT Parallel Printer Port; 200 Datasets/Curves Memory
Dimensiones & Peso Instrument: 490 × 370 × 180 milímetros (Ancho × Fondo × Alto); Peso Total: 14 kilos (33.07 libra)

Accesorios del paquete estándar incluidos

  • Unidad anfitriona principal: BRT-1200UV Benchtop UV Vis Spectrophotometer (1 unidad).
  • Quartz Cuvettes: 10 mm Cubetas de cuarzo estándar (2 pcs for Ultraviolet spectrum testing).
  • Glass Cuvettes: 10 mm Cubetas de vidrio estándar (4 pcs for Visible spectrum testing).
  • Sample Cell Holder: Standard Multi-Position Cell Holder.
  • Fuerza & Data Cabling: AC Power Cable, USB Interface Connection Cable.
  • Documentación & Software: User Operation Manual, Certificate of Quality, Tarjeta de garantía.

Flujo de trabajo de prueba & Aplicaciones de destino

Flujo de trabajo de pruebas estandarizado:

  1. Power on the BRT-1200UV; allow the microcomputer system to execute self-testing, light source switching, and baseline initialization.
  2. Select Photometric or Quantitative mode from the LCD menu interface.
  3. Load a blank reference solution in the cuvette chamber and initiate automatic 0A / 100%T zeroing.
  4. Introduce standard samples (arriba a 9 points) to build a multi-point quantitative calibration curve, or place test samples for immediate concentration readout.
  5. Save measurement data (arriba a 200 datasets) to internal memory, stream via USB to PC software, or output directly to a printer via the LPT parallel port.

Aplicaciones de clientes objetivo:

  • Environmental testing laboratories (BACALAO, heavy metals, nitrato, and phosphate concentration assays).
  • Pharmaceutical processing facilities, ingrediente farmacéutico activo (API) labs, and life science centers.
  • Petrochemical quality control bays, chemical plants, and agriculture/fertilizer testing labs.
  • University teaching laboratories, academic research centers, and food & beverage QA labs.

UV Vis Spectrophotometer FAQ

Q1: What is the main difference in performance between wavelength repeatability and accuracy on the BRT-1200UV?

A: Wavelength accuracy (±2 nm) measures how closely the selected wavelength matches the true physical value. Wavelength repeatability (≤0.5 nm) indicates how consistently the instrument returns to the exact same wavelength during repeated tests, ensuring high measurement precision.

Q2: How does multi-point standard curve fitting work on this model?

A: The BRT-1200UV allows users to analyze up to 9 standard sample concentrations directly on the instrument to establish a linear regression equation, display the curve, and automatically calculate unknown sample concentrations.

Q3: Can I run full spectral scanning or kinetics on the BRT-1200UV?

A: Sí. While standalone operation handles photometric and quantitative tests, connecting the instrument to a PC via USB with the optional analysis software enables kinetic tracking and full spectral scanning capabilities.

Reseñas

Aún no hay reseñas.

Sé el primero en opinar “BRT-1200UV UV Vis Spectrophotometer”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *