{"id":709,"date":"2026-09-11T16:31:09","date_gmt":"2026-09-11T08:31:09","guid":{"rendered":"https:\/\/brt-testing.com\/?post_type=product&#038;p=709"},"modified":"2026-09-23T14:16:42","modified_gmt":"2026-09-23T06:16:42","slug":"radiant-heat-flux-tester","status":"publish","type":"product","link":"https:\/\/brt-testing.com\/es\/product\/radiant-heat-flux-tester\/","title":{"rendered":"PDCL-01 Radiant Heat Flux Tester"},"content":{"rendered":"<p><!-- 1. Executive Summary & Value Proposition --><\/p>\n<p>The <strong>Baoruitong PDCL-01 Radiant Heat Flux Test Apparatus for Floor Coverings<\/strong> is a high-precision, computerized laboratory testing system designed to evaluate the critical radiant flux, burning behaviour, and flame spread of various flooring materials and underlays under controlled radiant heat exposure. Engineered strictly according to <strong>ISO 9239-1<\/strong>, <strong>ASTM E648<\/strong>, <strong>EN 13501-1 (Euroclass A2fl\u2013Dfl)<\/strong>, <strong>NFPA 253<\/strong>, and national standard <strong>GB\/T 11785-2005<\/strong>, this system provides essential flammability data for building safety certification.<\/p>\n<p>Featuring a heavy-duty CNC-machined 304 stainless steel combustion chamber (L1420 \u00d7 W1200 \u00d7 H2300 mm), a high-accuracy 0\u201315 kW\/m\u00b2 heat flux meter, automated exhaust velocity regulation (2.5 \u00b1 0.2 m\/s), and precision pilot flame positioning (60\u2013120 mm), this advanced <strong>Flooring Critical Radiant Flux Apparatus<\/strong> ensures repeatable testing for carpet mills, resilient flooring manufacturers, wood\/laminate producers, and certified fire safety testing laboratories.<\/p>\n<hr \/>\n<p><!-- 2. Applicable Standards & Test Classifications --><\/p>\n<h3>Flooring Radiant Heat Flux Tester Compliance &amp; Standards<\/h3>\n<p>This radiant panel flammability tester enables accredited testing laboratories to conduct certified Critical Radiant Flux (CRF) and reaction-to-fire evaluations across global standards:<\/p>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr style=\"background-color: #f8f9fa;\">\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Standard Code<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Standard Title &amp; Scope<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Primary Testing Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>ISO 9239-1<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Reaction to fire tests for floorings \u2014 Part 1: Determination of the burning behaviour using a radiant heat source<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">International benchmark testing for critical radiant flux determination on all flooring systems and underlays<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>ASTM E648 &amp; NFPA 253<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Standard test method for critical radiant flux of floor-covering systems using a radiant heat energy source<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">North American commercial building code compliance testing (Class I and Class II flooring requirements)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>EN 13501-1 (Euroclass)<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Fire classification of construction products and building elements \u2014 Flooring reaction to fire<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Mandatory CE marking classification testing for European flooring materials (Euroclasses A2fl, Bfl, Cfl, Dfl)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>GB\/T 11785-2005<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Reaction to fire tests for floorings \u2014 Determination of the burning behaviour using a radiant heat source<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Mandatory Chinese national standard for critical radiant flux evaluation of textile, wood, and plastic floorings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 3. Key Technological Advantages --><\/p>\n<h3>Technological Features of Baoruitong PDCL-01 Radiant Heat Flux Apparatus<\/h3>\n<ul>\n<li><strong>Premium Stainless Steel Construction:<\/strong> Built with high-grade 304 stainless steel plates formed by precision CNC machining, featuring corrosion resistance and a modern rounded aesthetic.<\/li>\n<li><strong>Precision Heat Flux Calibration System:<\/strong> Equipped with a 0\u201315 kW\/m\u00b2 heat flux meter and a hot-bulb anemometer (accuracy \u00b10.1 m\/s) to ensure accurate thermal gradient profiling along the specimen surface.<\/li>\n<li><strong>Controlled Airflow Dynamics:<\/strong> Automated exhaust blower system maintains chamber exhaust air velocity strictly within &gt; (2.5 \u00b1 0.2) m\/s with a tight temperature deviation control (&lt; \u00b110 \u00b0C).<\/li>\n<li><strong>In-House Custom 304 SS Burner:<\/strong> Manufactured strictly according to GB\/T 11785 \/ ISO 9239 specifications, delivering adjustable pilot flame heights from 60 mm to 120 mm.<\/li>\n<li><strong>Multi-Gas Compatibility:<\/strong> Operates seamlessly with industrial methane, propane, or liquefied petroleum gas (LPG) with purity \u2265 95%.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 4. Technical Specifications --><\/p>\n<h3>Technical Specifications of Baoruitong PDCL-01 Floor Flammability Machine<\/h3>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px; width: 35%;\"><strong>Governing Test Standards<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">ISO 9239-1, ASTM E648, EN ISO 9239-1, NFPA 253, GB\/T 11785-2005<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Combustion Chamber Dimensions<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">L1420 mm \u00d7 W1200 mm \u00d7 H2300 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Chamber &amp; Cabinet Material<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">High-grade 304 stainless steel &amp; thickened electroplated A3 anti-corrosion steel<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Heat Flux Meter Range<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">0 to 15 kW\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Exhaust Air Velocity<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">&gt; (2.5 \u00b1 0.2) m\/s; Anemometer accuracy \u00b10.1 m\/s<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Pilot Flame Height Range<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">60 mm to 120 mm (Adjustable)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Combustible Gas Options<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Methane, propane, or LPG (Purity \u2265 95%)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Operating Environment &amp; Power<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Room temp: 15 \u00b0C to 25 \u00b0C; Relative Humidity \u2264 75%; AC 220 V \u00b1 10 V, 50 Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 5. Applications & Workflow --><\/p>\n<h3>System Architecture &amp; Testing Workflow of PDCL-01 Flooring Tester<\/h3>\n<p><strong>Standardized Testing Workflow:<\/strong><\/p>\n<ol>\n<li>Prepare flooring specimens (including intended substrate and underlay) and condition at 23 \u00b0C \u00b1 2 \u00b0C and 50% \u00b1 5% RH.<\/li>\n<li>Calibrate the radiant panel to establish the standardized thermal radiation gradient (11 kW\/m\u00b2 at the hot end down to 1 kW\/m\u00b2 at the cool end).<\/li>\n<li>Mount the specimen horizontally inside the combustion chamber beneath the inclined radiant panel.<\/li>\n<li>Ignite the pilot gas burner (flame height 60\u2013120 mm) and apply to the hotter end of the specimen.<\/li>\n<li>Monitor flame spread along the length of the flooring and determine the Critical Radiant Flux (CRF in kW\/m\u00b2) at the point of flame extinction.<\/li>\n<\/ol>\n<p><strong>Target Customer Applications:<\/strong><\/p>\n<ul>\n<li>Textile carpet, rug, and underlay padding manufacturers.<\/li>\n<li>Hardwood, engineered timber, LVT, vinyl, and laminate flooring factories.<\/li>\n<li>Third-party fire safety inspection centers and ISO 17025 testing laboratories.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 6. Frequently Asked Questions (FAQ) --><\/p>\n<h3>Baoruitong PDCL-01 Radiant Heat Flux Test Apparatus FAQ<\/h3>\n<h4>Q1: What is Critical Radiant Flux (CRF) in flooring testing?<\/h4>\n<p><strong>A:<\/strong> Critical Radiant Flux (expressed in kW\/m\u00b2) is the level of radiant heat energy incident on the flooring surface at the point where the flame ceases to advance. A higher CRF value indicates superior fire resistance.<\/p>\n<h4>Q2: Does this machine satisfy North American ASTM E648 testing requirements?<\/h4>\n<p><strong>A:<\/strong> Yes. The chamber dimensions, radiant panel angle, pilot burner geometry, gas supply specifications, and heat flux measurement capabilities meet ASTM E648 and NFPA 253 criteria.<\/p>\n<h4>Q3: Why is substrate selection important during testing?<\/h4>\n<p><strong>A:<\/strong> Changes in underlay, adhesive, or backing material significantly alter heat absorption and flame spread. The PDCL-01 tests the complete flooring system assembly for realistic fire performance evaluation.<\/p>","protected":false},"excerpt":{"rendered":"<p><b data-path-to-node=\"7,0\" data-index-in-node=\"0\">PDCL-01 Radiant Heat Flux Tester<\/b> strictly designed for ISO 9239-1, ASTM E648, EN ISO 9239-1, NFPA 253, GB\/T 11785-2005 flooring fire reaction testing. Features a custom 304 stainless steel radiant burner, 0\u201315 kW\/m\u00b2 heat flux meter, \u00b10.1 m\/s anemometer for 2.5 m\/s steady airflow, split stainless steel cabinet, and multi-gas compatibility (Methane\/Propane\/LPG) to accurately determine critical radiant flux in carpets, wood, PVC, and composite floorings.<\/p>","protected":false},"featured_media":716,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[117],"product_cat":[24],"product_tag":[],"class_list":["post-709","product","type-product","status-publish","has-post-thumbnail","product_brand-brt-testing","product_cat-fire-flame-testing-equipment","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/product\/709","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/comments?post=709"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/media\/716"}],"wp:attachment":[{"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/media?parent=709"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/product_brand?post=709"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/product_cat?post=709"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/brt-testing.com\/es\/wp-json\/wp\/v2\/product_tag?post=709"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}