{"id":1929,"date":"2026-11-19T15:53:17","date_gmt":"2026-11-19T07:53:17","guid":{"rendered":"https:\/\/brt-testing.com\/?post_type=product&#038;p=1929"},"modified":"2026-11-19T15:57:05","modified_gmt":"2026-11-19T07:57:05","slug":"brt-aa2000-flame-graphite-furnace-aas","status":"publish","type":"product","link":"https:\/\/brt-testing.com\/fr\/product\/brt-aa2000-flame-graphite-furnace-aas\/","title":{"rendered":"BRT AA2000 Flame and Graphite Furnace AAS"},"content":{"rendered":"<h3>Product overview<\/h3>\n<p>The <strong>BRT AA2000<\/strong> integrates flame and graphite furnace atomization in one system. It is built for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis, combining a titanium flame burner with longitudinal graphite furnace heating and self-reversal background correction.<\/p>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-front-left-view.png\" alt=\"BRT AAS instrument viewed from front left with open sample compartment and autosampler attached\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Front-left three-quarter view of the BRT AAS system with the graphite furnace sampler fitted.<\/figcaption><\/figure>\n<h3>Key features across the series<\/h3>\n<ul>\n<li>Total-reflection optical system designed for high signal-to-noise performance.<\/li>\n<li>Eight-lamp turret with 360\u00b0 rotation and simultaneous preheating of 1\u20134 lamps.<\/li>\n<li>Windows workstation software with automatic control, QA\/QC functions, SD\/RSD calculation and calibration-curve correlation checking.<\/li>\n<li>Multiple data-processing modes including average, peak height, peak area and statistical analysis.<\/li>\n<li>One-click database access for wavelength, spectral bandwidth, lamp current, negative high voltage and energy-balance settings.<\/li>\n<\/ul>\n<h3>Optical system and photometric performance<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Instrument type<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame system<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame &#038; GFAA integrated<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame &#038; GFAA integrated<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Beam type<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Double-beam<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Double-beam<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Double-beam<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Diffraction grating<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1800 lines\/mm; blaze wavelength 250 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1800 lines\/mm; blaze wavelength 250 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1800 lines\/mm; blaze wavelength 250 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Wavelength range<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">185\u2013900 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">185\u2013900 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">185\u2013900 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Spectral bandwidth<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Wavelength accuracy<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.15 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.20 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.15 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Wavelength repeatability<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.05 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.10 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.05 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Spectral bandwidth deviation<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.02 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.02 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.02 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Lamp stand<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">8 lamps; simultaneous preheating of 1\u20134 lamps<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">8 lamps; simultaneous preheating of 1\u20134 lamps<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">8 lamps; simultaneous preheating of 1\u20134 lamps<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-front-view.png\" alt=\"Front view of the BRT AAS with both housings, open sample compartment, cyan tubing and autosampler lid\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Straight-on front view of the AAS with both atomization units visible.<\/figcaption><\/figure>\n<h3>Photometric performance<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Reading modes<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Transmittance, absorbance, concentration<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Transmittance, absorbance, concentration<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Transmittance, absorbance, concentration<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Photometric range<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0\u2013125%T; \u22120.1\u20133.00 Abs<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0\u2013125%T; \u22120.1\u20133.00 Abs<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0\u2013125%T; \u22120.1\u20133.00 Abs<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Baseline stability<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.002 Abs (steady 30 min); \u00b10.004 Abs (dynamic 15 min)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.003 Abs (steady 30 min); \u00b10.005 Abs (dynamic 15 min)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.002 Abs (steady 30 min); \u00b10.004 Abs (dynamic 15 min)<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Background correction<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">D\u2082 lamp \u226540-fold (1 Abs); self-reversal \u226580-fold (1 Abs)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">D\u2082 lamp \u226540-fold (1 Abs)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">D\u2082 lamp \u226540-fold (1 Abs); self-reversal \u226580-fold (1 Abs)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Flame analysis<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Characteristic concentration (Cu)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.02 \u03bcg\/mL<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.035 \u03bcg\/mL<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.02 \u03bcg\/mL<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Detection limit (Cu)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.004 \u03bcg\/mL<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.006 \u03bcg\/mL<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.004 \u03bcg\/mL<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Repeatability (Cu)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.5%<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.6%<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.5%<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Burner<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Titanium burner head<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Titanium burner head<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Titanium burner head<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Nebulizer<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">High-efficiency glass nebulizer<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">High-efficiency glass nebulizer<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">High-efficiency glass nebulizer<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Safety<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame gas &#038; auxiliary gas abnormal-pressure protection<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame gas &#038; auxiliary gas abnormal-pressure protection<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame gas &#038; auxiliary gas abnormal-pressure protection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Graphite furnace analysis<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Characteristic mass<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cd \u22640.6 pg; Cu \u226420 pg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cd \u22640.5 pg; Cu \u226420 pg<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Detection limit<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cd \u22641.0 pg; Cu \u226425 pg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cd \u22640.8 pg; Cu \u226425 pg<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Repeatability (Cd)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22643%<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22642.5%<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Temperature range<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">RT\u20133000 \u00b0C<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">RT\u20133000 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Heating rate<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Max. 2000 \u00b0C\/s<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Max. 2000 \u00b0C\/s<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Safety<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cooling-water flow, protective-gas pressure, furnace-body temperature, power-supply temperature and graphite-tube installation alarms<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cooling-water flow, protective-gas pressure, furnace-body temperature, power-supply temperature and graphite-tube installation alarms<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Inside the sample compartment<\/h3>\n<p>The graphite furnace workhead, injection assembly and sample bottle sit in the open sample compartment. Longitudinal furnace heating provides uniform gas-phase temperature, rapid atomization and stable analytical performance.<\/p>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-sample-compartment-interior.png\" alt=\"Close-up of graphite furnace workhead, injection assembly and sample bottle inside the BRT AAS sample compartment\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Close-up of the graphite furnace workhead and injection assembly inside the sample compartment.<\/figcaption><\/figure>\n<h3>Autosampler and front-panel controls<\/h3>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-autosampler-module.png\" alt=\"Close-up of cylindrical autosampler module with matte black lid and vertical Ignition, TurnOff, AutoZero, StartTest buttons\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Detail of the autosampler lid and the vertical control buttons.<\/figcaption><\/figure>\n<h3>Data processing<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Concentration calculation<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Standard curve (6 linear\/non-linear fitting methods), standard addition and interpolation<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Standard curve (6 linear\/non-linear fitting methods), standard addition and interpolation<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Standard curve (6 linear\/non-linear fitting methods), standard addition and interpolation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Repeated measurements<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1\u201330 times; average, SD and RSD of absorbance\/concentration<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1\u201330 times; average, SD and RSD of absorbance\/concentration<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1\u201330 times; average, SD and RSD of absorbance\/concentration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Accessories and physical data<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Standard accessories<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cu lamp \u00d71; oil-free air compressor; software; USB flash drive<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cu lamp \u00d71; Cd lamp \u00d71; oil-free air compressor; software; USB flash drive; graphite tube \u00d75; pipette \u00d71 (5\u201350 \u03bcL); pipette tips \u00d71000 (200 \u03bcL)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cu lamp \u00d71; Cd lamp \u00d71; oil-free air compressor; software; USB flash drive; graphite tube \u00d75; pipette \u00d71 (5\u201350 \u03bcL); pipette tips \u00d71000 (200 \u03bcL)<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Optional accessories<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; flame autosampler<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Power supply<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">AC 220 V, 50\/60 Hz<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">AC 220 V, 50\/60 Hz<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">AC 220 V, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">External size (W\u00d7D\u00d7H)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">830\u00d7650\u00d7560 mm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">830\u00d7650\u00d7560 mm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">830\u00d7650\u00d7560 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Package size (W\u00d7D\u00d7H)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1010\u00d7780\u00d7830 mm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1010\u00d7780\u00d7830 mm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1010\u00d7780\u00d7830 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Net weight<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">85 kg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">120 kg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">125 kg<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Gross weight<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">135 kg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">183 kg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">183 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Service connections and installation<\/h3>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-rear-panel-connections.png\" alt=\"Close-up of BRT AAS rear panel with cooling louvres, brand plate, mains inlet and gas and water connectors\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Detail of the rear panel with power inlet and gas\/water connectors.<\/figcaption><\/figure>\n<p>Rear-panel mains inlet, gas and water connectors are grouped for bench installation. The instrument sits on vibration-isolation feet; unpacking and leveling are required before atomizer alignment.<\/p>\n<h3>Frequently asked questions<\/h3>\n<h4>What elements can this AAS determine?<\/h4>\n<p>The series is specified for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. Element-specific detection limits are supplied for Cu and Cd in the datasheet; limits for other elements must be confirmed against your application.<\/p>\n<h4>What is the wavelength range?<\/h4>\n<p>All three models cover 185\u2013900 nm with a 1800 lines\/mm grating blazed at 250 nm.<\/p>\n<h4>How many lamps can be fitted?<\/h4>\n<p>The turret holds eight lamps and can preheat 1\u20134 lamps simultaneously.<\/p>\n<h4>What does the graphite furnace add?<\/h4>\n<p>Graphite furnace atomization extends the instrument to lower mass detection limits \u2014 the datasheet lists Cd \u22641.0 pg (AA1900) and Cd \u22640.8 pg (AA2000), with a temperature range up to 3000 \u00b0C.<\/p>\n<h4>Which background correction is fitted?<\/h4>\n<p>AA1800 and AA2000 specify D\u2082 lamp \u226540-fold (1 Abs) and self-reversal \u226580-fold (1 Abs). AA1900 specifies D\u2082 lamp \u226540-fold (1 Abs).<\/p>\n<h4>What data processing is available?<\/h4>\n<p>Standard curve with six linear\/non-linear fitting methods, standard addition and interpolation; 1\u201330 repeated measurements with average, SD and RSD.<\/p>\n<h4>What power supply is required?<\/h4>\n<p>AC 220 V, 50\/60 Hz for all three models.<\/p>\n<h3>Related models<\/h3>\n<p>Compare also: <a href=\"\/fr\/product\/brt-aa1800-flame-atomic-absorption-spectrophotometer\/\">BRT AA1800<\/a> <a href=\"\/fr\/product\/brt-aa1900-flame-graphite-furnace-aas\/\">BRT AA1900<\/a>.<\/p>\n<p><a href=\"\/fr\/product\/atomic-absorption-spectrophotometer\/\">See the complete BRT AAS series comparison<\/a>.<\/p>\n<h3>Request a quotation<\/h3>\n<p>Specify your element list, sample matrix, required detection limits and atomization mode (flame only or flame + graphite furnace). BRT will confirm the configuration, accessory set and delivery terms. Contact <strong>info@brt-test.com<\/strong> or WhatsApp <strong>+86 156 0405 7553<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>BRT AA2000 flame and graphite furnace AAS with \u00b10.15 nm wavelength accuracy, 3000 \u00b0C furnace and six-point curve fitting. Full specification set.<\/p>","protected":false},"featured_media":1925,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[143],"product_tag":[],"class_list":["post-1929","product","type-product","status-publish","has-post-thumbnail","product_cat-atomic-absorption-spectrophotometer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/product\/1929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/comments?post=1929"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/media\/1925"}],"wp:attachment":[{"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/media?parent=1929"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1929"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1929"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/brt-testing.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}