How Does a Spectrophotometer Measure Absorbance?

A spectrophotometer does not measure darkness; it measures a ratio. Two readings of the same light beam — one through the reference, one through the sample — are divided to give transmittance and then converted with a negative logarithm to give absorbance. This article follows that chain from lamp to detector, explains why the scale has to be logarithmic, sets out the Beer-Lambert relationship and the six ways the reading departs from it, and shows how to verify that the number the instrument prints is one you can defend.

Por |2026-10-27T13:40:14+08:00outubro 21, 2026|Blogue|0 Comentários

CEI 60695 Teste de inflamabilidade: A Practical Guide

CEI 60695 is not one test but a family of fire hazard test methods, and the product standard rather than IEC 60695 decides which method applies and at what severity. This guide maps the series by ignition source, separates GWEPT from GWFI and GWIT, sets out what changed in the 2021 editions, explains why a V-0 datasheet is not compliance evidence for a finished assembly, and gives the sequence in which to run the tests and specify the equipment.

Por |2026-10-27T13:40:24+08:00outubro 21, 2026|Interpretação da Norma|0 Comentários

Fire Resistance Testing for Steel Structures: Key Requirements

Fire resistance testing for steel structures produces a time rating for a protected member, not a property of the steel itself. That rating depends on the load ratio, the section factor, the protection type and the thickness applied, and it is extended to other sections by calculation in an assessment report. This guide sets out what an R 60 or R 90 rating actually describes, the three protection routes and the standard each one is assessed against, how a loaded furnace test is run, and the site changes that void a rating after it has been issued.

Por |2026-10-27T13:40:19+08:00outubro 20, 2026|Interpretação da Norma|0 Comentários

How to Test the Fire Performance of Building Insulation Materials

Testing the fire performance of building insulation is not a single test, and which test decides the result depends on the product. Mineral wool is settled by non-combustibility and calorific potential; EPS and PIR are settled by the SBI and the small-flame test; foil-faced boards are settled by their facings. This guide maps the four reaction-to-fire methods behind a Euroclass, the criteria that decide each class, and the three tests that sit outside the classification system, including ASTM E84 for North America and NFPA 285 for facade assemblies. It also covers pipe insulation's separate L classes, the specimen preparation errors that cause most retests, and the seven fields a test report must state before a class can be quoted in a tender.

Por |2026-10-27T13:40:04+08:00outubro 20, 2026|Interpretação da Norma|0 Comentários

FTIR vs UV-Vis: Which Spectroscopic Technique Should You Use?

FTIR and UV-Vis are both spectroscopic techniques, and that is where the similarity ends. FTIR reads molecular vibrations in the mid-infrared and identifies what a material is; UV-Vis reads electronic transitions in the ultraviolet and visible and quantifies how much of a known substance is in solution. This comparison sets the two side by side: what each one measures, the sample preparation each demands, how the same specification words mean different things on the two datasheets, where quantitative capability really ends, and which laboratories genuinely need both instruments rather than one.

Por |2026-10-27T13:39:59+08:00outubro 20, 2026|Blogue|0 Comentários

Fire Resistance vs Flame Retardancy: What Is the Difference?

Fire resistance and flame retardancy are two different properties, measured by two different families of tests, and one never implies the other. Fire resistance is a time-based rating of a loaded assembly inside a furnace, classified under EN 13501-2. Flame retardancy describes how a material responds to a defined ignition source, classified under EN 13501-1 or screened with UL 94. This guide sets the two side by side: which standards govern each, what a report line actually proves, how a steel column and a fire-resistant cable end up carrying both kinds of evidence, where flame-retardant claims break down in service, and the four questions to answer before writing a fire requirement.

Por |2026-10-27T13:39:54+08:00outubro 20, 2026|Interpretação da Norma|0 Comentários

Teste de inflamabilidade horizontal vs vertical para plásticos

Horizontal and vertical flammability testing for plastics look like the same test turned through ninety degrees. Eles não são. The orientation changes what the flame can do to the specimen, which property is measured, and which standards apply, so a horizontal result cannot be converted into a vertical one. This guide compares the two set-ups side by side, sets out the standards behind each orientation including ASTM D635, ASTM D3801 and IEC 60695-11-10, explains how thickness, pigment and conditioning move results more than orientation does, and shows how to specify equipment that covers both.

Por |2026-10-27T13:39:45+08:00outubro 19, 2026|Blogue|0 Comentários

Como escolher um fornecedor de equipamentos de laboratório para testes de incêndio

Choosing a fire testing laboratory equipment supplier is a decision about evidence, not about brochures. The instrument has to reproduce a published method, the calibration has to be traceable, and the supplier has to still be there when a thermocouple fails during an accreditation audit. This guide sets out the six criteria that predict whether an installation works, how to read a quotation, what to ask an application engineer, and the red flags that appear before a purchase order rather than after it.

Por |2026-10-27T13:39:49+08:00outubro 19, 2026|Blogue|0 Comentários

Para que é usado um espectrômetro FTIR? 8 Usos principais

An FTIR spectrometer is used to identify what a material is made of, by measuring how it absorbs mid-infrared light. This guide sets out the eight core uses, from polymer identification and incoming raw-material screening to contaminant analysis, coating verification and forensic fibre work, and explains which sampling mode fits each one. It also covers what FTIR cannot tell you, how transmission and ATR differ in practice, which instrument specifications actually matter for routine identification work, and the mistakes that most often produce an unusable spectrum.

Por |2026-10-27T13:39:35+08:00outubro 19, 2026|Blogue|0 Comentários

Fire Retardant Coating Testing: Methods and Equipment

Fire retardant coating testing is not one test. It is a family of methods that answer three different questions: whether a protected steel member still holds its fire resistance, how the coating itself behaves when it burns, and whether a formulation passes a fast screening check. This guide sets out the six methods that carry most commercial approvals, including EN 13381-8 for reactive protection to steel, ASTM E119 and ISO 834 furnace work, cone calorimeter and SBI reaction-to-fire routes, and the small-scale tests used before either. It also covers the equipment each route needs, how to read a test report, and the preparation errors that void otherwise good results.

Por |2026-10-27T13:39:40+08:00outubro 19, 2026|Interpretação da Norma|0 Comentários