{"id":1136,"date":"2026-09-18T13:02:03","date_gmt":"2026-09-18T05:02:03","guid":{"rendered":"https:\/\/brt-testing.com\/?post_type=product&#038;p=1136"},"modified":"2026-09-23T14:44:32","modified_gmt":"2026-09-23T06:44:32","slug":"brt-5800uv-uv-vis-spectrophotometer","status":"publish","type":"product","link":"https:\/\/brt-testing.com\/pt\/product\/brt-5800uv-uv-vis-spectrophotometer\/","title":{"rendered":"BRT-5800UV UV Vis Spectrophotometer"},"content":{"rendered":"<p><!-- 1. Executive Summary & Value Proposition --><\/p>\n<p>The <strong>BRT-5800UV UV Vis Spectrophotometer<\/strong> is a high-precision double-beam analytical instrument built on a Czerny-Turner (C-T) monochromator optical architecture, a 1200 lines\/mm holographic grating, and a high-sensitivity silicon photocell detector. Engineered for demanding pharmaceutical research, environmental compliance labs, chemical quality control facilities, and molecular biology institutes, it delivers an extended linear absorbance range up to 4.000 Abs across the 190 nm to 1100 nm spectral spectrum with a 1.8 nm bandwidth, \u00b10.3 nm wavelength accuracy, and 0.2 nm wavelength repeatability.<\/p>\n<p>Featuring dual deuterium and tungsten halogen light sources with adjustable switching points, this research-grade <strong>UV Vis Spectrophotometer<\/strong> guarantees superior transmittance accuracy (\u00b10.3%T) and exceptional optical baseline stability. Equipped with a 320\u00d7240 blue LCD screen, automated startup wavelength calibration, onboard memory for 200 datasets and standard curves, high-speed USB data export, and LPT parallel printer output, the 17 kg BRT-5800UV provides accurate quantitative analysis and routine photometric testing.<\/p>\n<hr \/>\n<p><!-- 2. Applicable Measurement Modes & Methodologies --><\/p>\n<h3>UV Vis Spectrophotometer Measurement &amp; Analysis Capabilities<\/h3>\n<p>This double-beam C-T monochromator spectrophotometer equips analytical chemists to execute complex photometric, quantitative, and kinetic testing workflows with automated baseline drift monitoring:<\/p>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr style=\"background-color: #f8f9fa;\">\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Analysis Mode<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Methodology &amp; Operational Scope<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Primary Testing Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Photometric Measurement<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Direct evaluation of Absorbance (-0.301 to 4.000 Abs) and Transmittance (0 to 200%T) at fixed user-defined wavelengths across 190\u20131100 nm<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">High-density sample optical screening, chemical raw material verification, and solution clarity testing<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Quantitative Concentration Profiling<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Concentration calculations using factor coefficients ($C = KA + B$) or multi-point linear calibration standard curves with automatic regression fitting<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Pharmaceutical active ingredient assays, environmental water testing (COD, nitrate, heavy metals), and chemical concentration checks<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>PC-Driven Kinetics &amp; Spectral Analysis<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Time-course dynamic tracking, multi-wavelength testing, and full spectral scanning using optional PC analysis software via USB connection<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Enzymatic reaction rates, dynamic degradation monitoring, nucleic acid\/protein assays, and complex chemical characterization<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 3. Key Technological Advantages --><\/p>\n<h3>Technological Features of BRT-5800UV UV Vis Spectrophotometer<\/h3>\n<ul>\n<li><strong>Double-Beam Optics &amp; C-T Monochromator Architecture<\/strong>Combines a double-beam optical layout with a Czerny-Turner monochromator and 1200 lines\/mm holographic grating to eliminate optical drift and ensure maximum signal purity.<\/li>\n<li><strong>Extended Absorbance Range (Up to 4.000 Abs)<\/strong>Provides an extended photometric dynamic range from -0.301 to 4.000 Abs, allowing accurate measurement of highly absorbing samples without requiring immediate dilution.<\/li>\n<li><strong>Narrow 1.8 nm Bandwidth &amp; High Resolution (0.1 nm Display)<\/strong>Delivers a tight 1.8 nm optical bandwidth across 190\u20131100 nm with 0.1 nm readout resolution, providing \u00b10.3 nm wavelength accuracy for sharp peak isolation.<\/li>\n<li><strong>Dual Light Sources with Adjustable Switching Points<\/strong>Features imported deuterium and tungsten halogen lamps with customizable switching points and microcomputer control to maximize lamp service life and operational stability.<\/li>\n<li><strong>Intelligent Startup Calibration &amp; Real-Time Stability Monitoring<\/strong>Automates wavelength calibration, 0A \/ 100%T zeroing upon startup, and actively monitors baseline stability throughout long testing sequences.<\/li>\n<li><strong>Dual Output Ports (USB PC Interface &amp; LPT Parallel Port)<\/strong>Equipped with a USB port for streaming digital data to optional PC analysis software and an LPT parallel port for outputting test results directly to dedicated printers.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 4. Technical Specifications --><\/p>\n<h3>Technical Specifications of UV Vis Spectrophotometer<\/h3>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px; width: 35%;\"><strong>Product Model<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">BRT-5800UV Dual Beam UV Vis Spectrophotometer<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Optical System &amp; Monochromator<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Double Beam Optics, C-T Monochromator, 1200 lines\/mm Holographic Grating<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Wavelength Spectrum &amp; Bandwidth<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">190 nm to 1100 nm; Spectral Bandwidth: 1.8 nm; Wavelength Resolution: 0.1 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Wavelength Accuracy &amp; Repeatability<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Accuracy: \u00b10.3 nm; Repeatability: 0.2 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Photometric Range &amp; Accuracy<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">0 to 200%T, -0.301 to 4.000 Abs, -9999 to 9999 C; Transmittance Accuracy: \u00b10.3%T<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Light Sources &amp; Detector<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Tungsten Halogen Lamp &amp; Imported Deuterium Lamp; Silicon Photocell Detector<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Display &amp; User Interface<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">320 \u00d7 240 Blue LCD Display Screen; Light-Touch Button Panel<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Data Output &amp; Memory Storage<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Stores 200 Datasets &amp; Standard Curves; USB Interface, LPT Parallel Printer Port<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Dimensions &amp; Instrument Weight<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">545 \u00d7 450 \u00d7 235 mm (L \u00d7 W \u00d7 H); Total Weight: 17 kg (37.48 lb)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 5. System Configuration & Package Components --><\/p>\n<h3>Standard Package Accessories Included<\/h3>\n<ul>\n<li><strong>Main Host Unit:<\/strong> BRT-5800UV Double Beam UV Vis Spectrophotometer (1 unit).<\/li>\n<li><strong>Sample Cell Holder:<\/strong> Fixed 2-Trench Cuvette Holder.<\/li>\n<li><strong>Quartz Cuvettes:<\/strong> 10 mm Standard Quartz Cuvettes (4 pcs for Ultraviolet spectrum testing).<\/li>\n<li><strong>Glass Cuvettes:<\/strong> 10 mm Standard Glass Cuvettes (4 pcs for Visible spectrum testing).<\/li>\n<li><strong>Power &amp; Data Connectivity:<\/strong> Dual-Voltage AC Power Cable, USB Interface Cable.<\/li>\n<li><strong>Documentation &amp; Software:<\/strong> Operating Manual, Quality Certificate, Warranty Card.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 6. Applications & Testing Workflow --><\/p>\n<h3>Testing Workflow &amp; Target Applications<\/h3>\n<p><strong>Standardized Testing Workflow:<\/strong><\/p>\n<ol>\n<li>Power on the BRT-5800UV; allow the microcomputer to initialize lamp switching, dark current zeroing, and startup wavelength calibration.<\/li>\n<li>Select Photometric or Quantitative mode on the 320\u00d7240 blue LCD display menu.<\/li>\n<li>Place a reference solvent blank into the reference position of the 2-trench holder to execute 0A \/ 100%T baseline zeroing.<\/li>\n<li>Place the sample into the testing path to obtain direct absorbance readings up to 4.000 Abs or compute concentrations using pre-stored calibration curves.<\/li>\n<li>Save measurement results (up to 200 datasets) in internal memory, export via USB interface to optional PC software, or print reports via the LPT parallel printer port.<\/li>\n<\/ol>\n<p><strong>Target Customer Applications:<\/strong><\/p>\n<ul>\n<li>Pharmaceutical testing laboratories, active pharmaceutical ingredient (API) assay facilities, and QA\/QC centers.<\/li>\n<li>Environmental inspection agencies (water quality, heavy metal detection, COD, and pollutant analysis).<\/li>\n<li>Biochemistry laboratories, molecular biology research facilities, and university testing bays.<\/li>\n<li>Chemical plants, food safety testing centers, and agricultural analysis stations.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 7. Frequently Asked Questions (FAQ) --><\/p>\n<h3>UV Vis Spectrophotometer FAQ<\/h3>\n<h4>Q1: What are the analytical advantages of the 4.000 Abs measuring range on the BRT-5800UV?<\/h4>\n<p><strong>A:<\/strong> An extended range up to 4.000 Abs allows technicians to measure dense or highly concentrated samples directly without performing manual serial dilutions, preserving sample integrity and reducing preparation errors.<\/p>\n<h4>Q2: How does the double-beam C-T monochromator optical system benefit daily lab testing?<\/h4>\n<p><strong>A:<\/strong> The double-beam C-T monochromator design splits light to continuously compensate for lamp drift and environmental changes. This guarantees high baseline flatness, minimal stray light, and excellent photometric reproducibility.<\/p>\n<h4>Q3: What analytical modes are supported when connecting the instrument to PC software via USB?<\/h4>\n<p><strong>A:<\/strong> Connecting to optional PC software via USB enables continuous spectrum scanning, dynamic time-course reaction kinetics, multi-wavelength testing, and customizable GLP laboratory report generation.<\/p>","protected":false},"excerpt":{"rendered":"<p><b data-path-to-node=\"7,0\" data-index-in-node=\"0\">BRT-5800UV UV Vis Spectrophotometer<\/b> is a 17 kg benchtop double-beam instrument featuring a 190\u20131100 nm spectral range, 1.8 nm bandwidth, C-T monochromator with 1200 lines\/mm grating, and an extended measuring range up to 4.000 Abs. Equipped with dual tungsten\/deuterium lamps, a 320\u00d7240 blue LCD screen, 200-dataset memory, 4 quartz\/4 glass cuvettes, USB connectivity, and LPT printer output, it delivers reliable photometric and quantitative analysis.<\/p>","protected":false},"featured_media":1137,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[117],"product_cat":[21],"product_tag":[],"class_list":["post-1136","product","type-product","status-publish","has-post-thumbnail","product_brand-brt-testing","product_cat-uv-vis-spectrophotometer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product\/1136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/comments?post=1136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/media\/1137"}],"wp:attachment":[{"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/media?parent=1136"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1136"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1136"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}