{"id":830,"date":"2026-09-14T16:33:59","date_gmt":"2026-09-14T08:33:59","guid":{"rendered":"https:\/\/brt-testing.com\/?post_type=product&#038;p=830"},"modified":"2026-09-23T14:15:04","modified_gmt":"2026-09-23T06:15:04","slug":"cable-fire-resistance-tester","status":"publish","type":"product","link":"https:\/\/brt-testing.com\/pt\/product\/cable-fire-resistance-tester\/","title":{"rendered":"NH-016 Cable Fire Resistance Tester Cable Circuit Integrity Testing Chamber"},"content":{"rendered":"<p><!-- 1. Executive Summary & Value Proposition --><\/p>\n<p>The <strong>NH-016 Wire and Cable Fire Resistance Tester (Cable Circuit Integrity Testing Chamber)<\/strong>\u00a0is a state-of-the-art laboratory testing system engineered to evaluate the circuit integrity of electric, data, and optical fiber cables under high-temperature flame, mechanical shock, and water spray conditions. It strictly complies with <strong>BS 6387:2013 (Protocols C, W, Z)<\/strong>, <strong>IEC 60331-1\/2\/3\/21\/23\/25<\/strong>, <strong>BS 8491<\/strong>, <strong>BS 8436<\/strong>, <strong>EN 50200<\/strong>, and <strong>GB\/T 19216<\/strong> standards.<\/p>\n<p>Featuring a spacious 3.0 m \u00d7 3.0 m \u00d7 3.0 m 304 stainless steel test chamber lined with 700\u00b0C fireproof insulation, dual high-precision ribbon burners (including a 610mm BS 6387 burner), an imported mass flow gas control system, and a 3-phase 5-circuit transformer with 0\u20131000V adjustable voltage load, this advanced <strong>Circuit Integrity Testing Equipment<\/strong> provides authoritative compliance data for cable manufacturers, power grid inspection bodies, construction safety authorities, and third-party testing laboratories worldwide.<\/p>\n<hr \/>\n<p><!-- 2. Applicable Standards & Test Classifications --><\/p>\n<h3>Wire &amp; Cable Fire Resistance Test Machine Compliance &amp; Standards<\/h3>\n<p>This circuit integrity test system enables certified labs to execute comprehensive fire resistance, shock, and water jet assessments across global cable standards:<\/p>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr style=\"background-color: #f8f9fa;\">\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Standard Code<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Standard Title &amp; Scope<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Primary Testing Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>BS 6387:2013<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions (Protocols C, W, Z)<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">British benchmark for fire alone (950\u00b0C), fire with water spray, and fire with mechanical shock testing<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>IEC 60331-1 \/ 2 \/ 3 \/ 21 \/ 23 \/ 25<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Tests for electric and optical fiber cables under fire conditions \u2014 Circuit integrity (Power, Data, Optical)<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">International standard series for electric power, control, data, and fiber optic cable circuit integrity under flame and shock<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>BS 8491 &amp; BS 8436<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Assessment of fire integrity for large diameter power cables &amp; 300\/500V screened multi-core building cables<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Evaluation of fire, shock, and water jet resistance for critical infrastructure and building emergency systems<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>EN 50200 \/ GB\/T 19216.21~25<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Fire resistance testing for small unprotected cables &amp; Mandatory Chinese national standard series<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">European and Chinese national compliance testing for emergency circuit wiring and small diameter cables<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>AS\/NZS 3013<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Electrical installations \u2014 Classification of fire and mechanical performance of wiring system components<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Australian\/New Zealand wiring safety classification under extreme thermal and mechanical impact conditions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 3. Key Technological Advantages --><\/p>\n<h3>Technological Features of NH-016 Cable Circuit Integrity Test Machine<\/h3>\n<ul>\n<li><strong>Insulated 3m \u00d7 3m \u00d7 3m Full-Scale Chamber:<\/strong> Constructed with a durable 304 stainless steel outer shell and 700\u00b0C high-temperature resistant internal thermal board. Includes a 750\u00b0C fireproof glass observation window and high-temperature sealant joints.<\/li>\n<li><strong>Dual Specialized Burner Assemblies:<\/strong> Features a 500mm burner with staggered triple-row nozzles for IEC 60331 testing, plus a dedicated 610mm propane ribbon burner specifically designed for BS 6387 Protocol C (950\u00b0C flame exposure).<\/li>\n<li><strong>Imported Mass Flow Controllers &amp; Gas Precision:<\/strong> Employs high-accuracy mass flow meters and dual 0.1 MPa pressure regulators with Venturi gas\/air mixers, maintaining precise, pulse-free flame temperature control between 600\u00b0C and 1000\u00b0C.<\/li>\n<li><strong>3-Phase 5-Circuit Electrical Load System:<\/strong> Equipped with a 5 kW transformer supporting 0\u20131000V adjustable test voltage and 0.1\u20133A current per circuit. Features fuses (2A), adjustable resistors, ammeters, and short-circuit auto-alarm protections.<\/li>\n<li><strong>Intelligent Auto-Control &amp; Multi-Parameter Alarming:<\/strong> Real-time K-type thermocouples capture flame temperature curves on the touchscreen display. Automatically cuts off gas supply, sounds alarms, and logs test results upon cable short-circuit or timer completion.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 4. Technical Specifications --><\/p>\n<h3>Technical Specifications of Cable Fire Resistance Test Apparatus<\/h3>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px; width: 35%;\"><strong>Governing Test Standards<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">BS 6387:2013, IEC 60331-1\/2\/3\/21\/23\/25, BS 8491, BS 8436, EN 50200, GB\/T 19216.21~25, AS\/NZS 3013<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Chamber Dimensions &amp; Shell<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">3.0 m (L) \u00d7 3.0 m (W) \u00d7 3.0 m (H); 304 Stainless Steel with 700\u00b0C interior fireproof lining<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Flame Burner Assemblies<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">\u2022 500 mm nozzle burner (1.32 mm hole radius, 3.2 mm spacing)<br \/>\n\u2022 610 mm BS 6387 Protocol C ribbon propane burner with Venturi mixer<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Flame Temperature Range<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">600\u00b0C \u2013 1000\u00b0C adjustable (Grade A: 650\u00b0C, Grade B: 750\u00b0C, Grades C\/D: 950\u00b0C); 1.5mm K-type sensors<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Test Power Transformer &amp; Load<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">3-phase transformer, 5 kW; Voltage: 0\u20131000V adjustable; Current: 0.1\u20133A across 5 independent circuits<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Gas &amp; Airflow Regulation<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Imported Mass Flow Controllers (MFC); 0.1 MPa dual pressure-reducing valves<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Control Unit &amp; Timer<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">PLC with touch screen display; Timer: 0\u201399 h 99 min 99 s; Automatic short-circuit trip &amp; flameout alarm<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Control Cabinet Dimensions<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">650 mm (D) \u00d7 400 mm (W) \u00d7 1200 mm (H)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 5. Applications & Workflow --><\/p>\n<h3>System Architecture &amp; Testing Workflow of NH-016 Fire Resistance Test Machine<\/h3>\n<p><strong>Standardized Testing Workflow:<\/strong><\/p>\n<ol>\n<li>Mount the sample cable onto the stainless steel ladder support and secure it using the 150mm metal rings.<\/li>\n<li>Connect the cable conductors to the 5-circuit electrical transformer load system and set the target test voltage (up to 1000V).<\/li>\n<li>Position the mobile ribbon burner at the specified distance (40\u201360 mm horizontally, 100\u2013120 mm vertically) from the specimen.<\/li>\n<li>Select the flame protocol (e.g., BS 6387 Protocol C at 950\u00b0C) and initiate high-voltage electronic spark ignition.<\/li>\n<li>The PLC tracks real-time current and temperature; if a conductor short-circuits or breaks circuit integrity, the system logs the failure time and triggers safety shut-off.<\/li>\n<\/ol>\n<p><strong>Target Customer Applications:<\/strong><\/p>\n<ul>\n<li>Fire-resistant power cable, communication line, and optical fiber cable manufacturers.<\/li>\n<li>Third-party electrical product inspection centers and international marine\/rail certification bodies.<\/li>\n<li>Power utility companies, metro infrastructure engineering agencies, and industrial R&amp;D centers.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 6. Frequently Asked Questions (FAQ) --><\/p>\n<h3>NH-016 Cable Fire Resistance Test Machine FAQ<\/h3>\n<h4>Q1: What is the main difference between BS 6387 Protocol C and IEC 60331 tests?<\/h4>\n<p><strong>A:<\/strong> BS 6387 Protocol C subjects the cable to a higher flame temperature of 950\u00b0C \u00b1 40\u00b0C using a 610mm ribbon burner for 180 minutes, whereas standard IEC 60331-21 tests typically apply a 750\u00b0C to 830\u00b0C flame. The NH-016 includes specialized burners to perform both tests seamlessly.<\/p>\n<h4>Q2: How does the system handle cable short-circuit events during high-voltage loading?<\/h4>\n<p><strong>A:<\/strong> Each of the 5 testing circuits is equipped with an independent fuse (2A) and circuit protection. When a cable insulation fails and causes a short-circuit, the system immediately cuts power to the affected channel, sounds an audible alarm, and records the exact time of breakdown.<\/p>\n<h4>Q3: Is the chamber suitable for water spray and mechanical shock testing?<\/h4>\n<p><strong>A:<\/strong> Yes. The heavy-duty 304 stainless steel rack and chamber structure are engineered with high load capacity and drainage considerations, accommodating auxiliary water spray nozzles and mechanical shock impact hammers required by BS 6387 Protocols W &amp; Z and BS 8491.<\/p>","protected":false},"excerpt":{"rendered":"<p data-path-to-node=\"11\"><b data-path-to-node=\"11\" data-index-in-node=\"0\">NH-016 Cable Fire Resistance Tester<\/b> is a high-precision, heavy-duty laboratory system designed to evaluate the circuit integrity, thermal endurance, and electrical survival of power, data, and optical cables under severe fire conditions up to <b data-path-to-node=\"11\" data-index-in-node=\"243\">1000\u00b0C<\/b> (with optional water spray &amp; mechanical shock).<\/p>\n<h4 data-path-to-node=\"12\"><b data-path-to-node=\"12\" data-index-in-node=\"0\">Key Features:<\/b><\/h4>\n<ul>\n<li data-path-to-node=\"13,0,0\"><b data-path-to-node=\"13,0,0\" data-index-in-node=\"0\">Multi-Standard Compliance:<\/b> Engineered strictly according to <b data-path-to-node=\"13,0,0\" data-index-in-node=\"60\">IEC 60331<\/b> (Parts 1\/2\/11\/21\/23\/25), <b data-path-to-node=\"13,0,0\" data-index-in-node=\"95\">BS 6387:2013<\/b>, <b data-path-to-node=\"13,0,0\" data-index-in-node=\"109\">BS 8491<\/b>, <b data-path-to-node=\"13,0,0\" data-index-in-node=\"118\">EN 50200<\/b>, and <b data-path-to-node=\"13,0,0\" data-index-in-node=\"132\">GB\/T 19216<\/b>.<\/li>\n<li data-path-to-node=\"13,1,0\"><b data-path-to-node=\"13,1,0\" data-index-in-node=\"0\">Heavy-Duty Chamber:<\/b> Integrated 3m \u00d7 3m \u00d7 3m 304 stainless steel insulated combustion chamber with high-temperature fireproof lining.<\/li>\n<li data-path-to-node=\"13,2,0\"><b data-path-to-node=\"13,2,0\" data-index-in-node=\"0\">5-Channel Independent Electrical Load:<\/b> Precise voltage and current control (<b data-path-to-node=\"13,2,0\" data-index-in-node=\"76\">0\u20131000V \/ 0.1\u20133A<\/b>) per channel.<\/li>\n<li data-path-to-node=\"13,3,0\"><b data-path-to-node=\"13,3,0\" data-index-in-node=\"0\">Precision Flame &amp; Gas Control:<\/b> Dual propane ribbon burners equipped with Mass Flow Controllers (MFC) for accurate temperature regulation.<\/li>\n<li data-path-to-node=\"13,4,0\"><b data-path-to-node=\"13,4,0\" data-index-in-node=\"0\">Automated Control:<\/b> Intuitive PLC touch-screen display for seamless operation, test automation, and real-time data logging.<\/li>\n<li data-path-to-node=\"13,5,0\"><b data-path-to-node=\"13,5,0\" data-index-in-node=\"0\">Target Applications:<\/b> Ideal for wire &amp; cable manufacturers, third-party fire testing agencies, rail transit, marine classification societies, and research institutes.<\/li>\n<\/ul>","protected":false},"featured_media":834,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[117],"product_cat":[24],"product_tag":[],"class_list":["post-830","product","type-product","status-publish","has-post-thumbnail","product_brand-brt-testing","product_cat-fire-flame-testing-equipment","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product\/830","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/comments?post=830"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/media\/834"}],"wp:attachment":[{"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/media?parent=830"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product_brand?post=830"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product_cat?post=830"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/brt-testing.com\/pt\/wp-json\/wp\/v2\/product_tag?post=830"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}