{"id":1926,"date":"2026-11-19T15:53:20","date_gmt":"2026-11-19T07:53:20","guid":{"rendered":"https:\/\/brt-testing.com\/?post_type=product&#038;p=1926"},"modified":"2026-11-19T15:56:34","modified_gmt":"2026-11-19T07:56:34","slug":"atomic-absorption-spectrophotometer","status":"publish","type":"product","link":"https:\/\/brt-testing.com\/tr\/product\/atomic-absorption-spectrophotometer\/","title":{"rendered":"Atomic Absorption Spectrophotometer: Flame and GFAA Systems"},"content":{"rendered":"<h3>Product overview<\/h3>\n<p><strong>BRT atomic absorption spectrophotometer<\/strong> systems are benchtop AAS instruments for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. The series covers three configurations: AA1800 (flame only), AA1900 and AA2000 (flame and graphite furnace atomization in one system). All three share a double-beam optical path, an 185\u2013900 nm wavelength range, an eight-lamp turret and Windows-based workstation software. This page brings the full series specification set together so you can compare models before requesting a quotation.<\/p>\n<h3>Choose your configuration<\/h3>\n<p>Each model has its own product page with the full specification table. Start from the model that matches your atomization requirement.<\/p>\n<div style=\"display:flex;flex-wrap:wrap;gap:18px;margin:1.5em 0\">\n<div style=\"flex:1 1 220px;border:1px solid 1px solid #c9ced6;padding:12px;text-align:center\"><a href=\"\/tr\/product\/brt-aa1800-flame-atomic-absorption-spectrophotometer\/\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-front-view.png\" alt=\"BRT AA1800 flame atomic absorption spectrophotometer\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto\"><\/a><\/p>\n<p><a href=\"\/tr\/product\/brt-aa1800-flame-atomic-absorption-spectrophotometer\/\"><strong>AA1800 \u2014 flame AAS<\/strong><\/a><\/p>\n<\/div>\n<div style=\"flex:1 1 220px;border:1px solid 1px solid #c9ced6;padding:12px;text-align:center\"><a href=\"\/tr\/product\/brt-aa1900-flame-graphite-furnace-aas\/\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-front-left-view.png\" alt=\"BRT AA1900 flame and graphite furnace atomic absorption spectrophotometer\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto\"><\/a><\/p>\n<p><a href=\"\/tr\/product\/brt-aa1900-flame-graphite-furnace-aas\/\"><strong>AA1900 \u2014 flame + graphite furnace<\/strong><\/a><\/p>\n<\/div>\n<div style=\"flex:1 1 220px;border:1px solid 1px solid #c9ced6;padding:12px;text-align:center\"><a href=\"\/tr\/product\/brt-aa2000-flame-graphite-furnace-aas\/\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-top-view.png\" alt=\"BRT AA2000 flame and graphite furnace AAS with autosampler\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto\"><\/a><\/p>\n<p><a href=\"\/tr\/product\/brt-aa2000-flame-graphite-furnace-aas\/\"><strong>AA2000 \u2014 flame + graphite furnace<\/strong><\/a><\/p>\n<\/div>\n<\/div>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-laboratory-application.png\" alt=\"BRT atomic absorption spectrometer installed on a clean laboratory bench with glassware and workstation monitors behind\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">The AAS shown installed on a bench in a modern analytical laboratory.<\/figcaption><\/figure>\n<h3>Key features across the series<\/h3>\n<ul>\n<li>Total-reflection optical system designed for high signal-to-noise performance.<\/li>\n<li>Eight-lamp turret with 360\u00b0 rotation and simultaneous preheating of 1\u20134 lamps.<\/li>\n<li>Windows workstation software with automatic control, QA\/QC functions, SD\/RSD calculation and calibration-curve correlation checking.<\/li>\n<li>Multiple data-processing modes including average, peak height, peak area and statistical analysis.<\/li>\n<li>One-click database access for wavelength, spectral bandwidth, lamp current, negative high voltage and energy-balance settings.<\/li>\n<\/ul>\n<h3>Series specification \u2014 optical system and photometric performance<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Instrument type<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame system<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame &#038; GFAA integrated<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame &#038; GFAA integrated<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Beam type<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Double-beam<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Double-beam<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Double-beam<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Diffraction grating<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1800 lines\/mm; blaze wavelength 250 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1800 lines\/mm; blaze wavelength 250 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1800 lines\/mm; blaze wavelength 250 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Wavelength range<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">185\u2013900 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">185\u2013900 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">185\u2013900 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Spectral bandwidth<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Wavelength accuracy<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.15 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.20 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.15 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Wavelength repeatability<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.05 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.10 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.05 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Spectral bandwidth deviation<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.02 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.02 nm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.02 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Lamp stand<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">8 lamps; simultaneous preheating of 1\u20134 lamps<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">8 lamps; simultaneous preheating of 1\u20134 lamps<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">8 lamps; simultaneous preheating of 1\u20134 lamps<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Series specification \u2014 photometric performance<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Reading modes<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Transmittance, absorbance, concentration<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Transmittance, absorbance, concentration<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Transmittance, absorbance, concentration<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Photometric range<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0\u2013125%T; \u22120.1\u20133.00 Abs<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0\u2013125%T; \u22120.1\u20133.00 Abs<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">0\u2013125%T; \u22120.1\u20133.00 Abs<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Baseline stability<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.002 Abs (steady 30 min); \u00b10.004 Abs (dynamic 15 min)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.003 Abs (steady 30 min); \u00b10.005 Abs (dynamic 15 min)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u00b10.002 Abs (steady 30 min); \u00b10.004 Abs (dynamic 15 min)<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Background correction<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">D\u2082 lamp \u226540-fold (1 Abs); self-reversal \u226580-fold (1 Abs)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">D\u2082 lamp \u226540-fold (1 Abs)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">D\u2082 lamp \u226540-fold (1 Abs); self-reversal \u226580-fold (1 Abs)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Series specification \u2014 flame analysis<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Characteristic concentration (Cu)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.02 \u03bcg\/mL<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.035 \u03bcg\/mL<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.02 \u03bcg\/mL<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Detection limit (Cu)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.004 \u03bcg\/mL<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.006 \u03bcg\/mL<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.004 \u03bcg\/mL<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Repeatability (Cu)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.5%<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.6%<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22640.5%<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Burner<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Titanium burner head<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Titanium burner head<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Titanium burner head<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Nebulizer<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">High-efficiency glass nebulizer<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">High-efficiency glass nebulizer<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">High-efficiency glass nebulizer<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Safety<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame gas &#038; auxiliary gas abnormal-pressure protection<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame gas &#038; auxiliary gas abnormal-pressure protection<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Flame gas &#038; auxiliary gas abnormal-pressure protection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Series specification \u2014 graphite furnace analysis<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Characteristic mass<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cd \u22640.6 pg; Cu \u226420 pg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cd \u22640.5 pg; Cu \u226420 pg<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Detection limit<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cd \u22641.0 pg; Cu \u226425 pg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cd \u22640.8 pg; Cu \u226425 pg<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Repeatability (Cd)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22643%<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u22642.5%<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Temperature range<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">RT\u20133000 \u00b0C<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">RT\u20133000 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Heating rate<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Max. 2000 \u00b0C\/s<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Max. 2000 \u00b0C\/s<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Safety<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">\u2014<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cooling-water flow, protective-gas pressure, furnace-body temperature, power-supply temperature and graphite-tube installation alarms<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cooling-water flow, protective-gas pressure, furnace-body temperature, power-supply temperature and graphite-tube installation alarms<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-top-view.png\" alt=\"Overhead view of the BRT AAS open sample compartment with graphite furnace workhead and white sample bottles\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Overhead view of the open sample compartment and graphite furnace workhead.<\/figcaption><\/figure>\n<h3>Series specification \u2014 data processing<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Concentration calculation<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Standard curve (6 linear\/non-linear fitting methods), standard addition and interpolation<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Standard curve (6 linear\/non-linear fitting methods), standard addition and interpolation<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Standard curve (6 linear\/non-linear fitting methods), standard addition and interpolation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Repeated measurements<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1\u201330 times; average, SD and RSD of absorbance\/concentration<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1\u201330 times; average, SD and RSD of absorbance\/concentration<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1\u201330 times; average, SD and RSD of absorbance\/concentration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Series specification \u2014 accessories and physical data<\/h3>\n<div class=\"brt-table-wrap\" style=\"overflow-x:auto;margin:1.5em 0\">\n<table style=\"border-collapse:collapse;width:100%;min-width:600px\">\n<thead>\n<tr>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">Parameter<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1800<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA1900<\/th>\n<th style=\"border:1px solid #c9ced6;background:#f2f4f7;font-weight:600;padding:9px 12px;text-align:left\">AA2000<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Standard accessories<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cu lamp \u00d71; oil-free air compressor; software; USB flash drive<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cu lamp \u00d71; Cd lamp \u00d71; oil-free air compressor; software; USB flash drive; graphite tube \u00d75; pipette \u00d71 (5\u201350 \u03bcL); pipette tips \u00d71000 (200 \u03bcL)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Cu lamp \u00d71; Cd lamp \u00d71; oil-free air compressor; software; USB flash drive; graphite tube \u00d75; pipette \u00d71 (5\u201350 \u03bcL); pipette tips \u00d71000 (200 \u03bcL)<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Optional accessories<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; flame autosampler<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Power supply<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">AC 220 V, 50\/60 Hz<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">AC 220 V, 50\/60 Hz<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">AC 220 V, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">External size (W\u00d7D\u00d7H)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">830\u00d7650\u00d7560 mm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">830\u00d7650\u00d7560 mm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">830\u00d7650\u00d7560 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Package size (W\u00d7D\u00d7H)<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1010\u00d7780\u00d7830 mm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1010\u00d7780\u00d7830 mm<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">1010\u00d7780\u00d7830 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Net weight<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">85 kg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">120 kg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">125 kg<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">Gross weight<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">135 kg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">183 kg<\/td>\n<td style=\"border:1px solid #c9ced6;padding:9px 12px;vertical-align:top\">183 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Flame AAS or flame + graphite furnace: which configuration?<\/h3>\n<p>Choose <strong>AA1800<\/strong> when the required concentration range is within flame AAS capability and a graphite furnace is not needed. Choose <strong>AA1900<\/strong> or <strong>AA2000<\/strong> when lower mass detection limits are required \u2014 the datasheet lists graphite furnace detection limits of Cd \u22641.0 pg (AA1900) and Cd \u22640.8 pg (AA2000), against flame Cu detection limits of \u22640.006 \u03bcg\/mL (AA1900) and \u22640.004 \u03bcg\/mL (AA2000). All three models share the same 185\u2013900 nm optical range, eight-lamp turret and AC 220 V supply.<\/p>\n<h3>Workhead and sampler<\/h3>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-sample-compartment-interior.png\" alt=\"Close-up of graphite furnace workhead, injection assembly and sample bottle inside the BRT AAS sample compartment\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Close-up of the graphite furnace workhead and injection assembly inside the sample compartment.<\/figcaption><\/figure>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-autosampler-module.png\" alt=\"Close-up of cylindrical autosampler module with matte black lid and vertical Ignition, TurnOff, AutoZero, StartTest buttons\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Detail of the autosampler lid and the vertical control buttons.<\/figcaption><\/figure>\n<h3>Installation connections<\/h3>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-rear-panel-connections.png\" alt=\"Close-up of BRT AAS rear panel with cooling louvres, brand plate, mains inlet and gas and water connectors\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Detail of the rear panel with power inlet and gas\/water connectors.<\/figcaption><\/figure>\n<h3>Other views<\/h3>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-front-right-view.png\" alt=\"BRT atomic absorption spectrometer seen from front right, showing the black circular autosampler lid and connection panel\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Front-right view highlighting the autosampler lid and rear signal connections.<\/figcaption><\/figure>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-left-side-view.png\" alt=\"Left side of the BRT AAS showing cooling vent, oval brand plate, open workhead and vertical control buttons\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Left-side view with cooling louvres, brand plate and control buttons labelled.<\/figcaption><\/figure>\n<figure style=\"margin:1.5em 0\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/brt-testing.com\/wp-content\/uploads\/2026\/11\/atomic-absorption-spectrophotometer-rear-view.png\" alt=\"Rear-left view of the BRT AAS showing mains inlet, gas and water connectors and red isolation feet\" width=\"1536\" height=\"1024\" style=\"max-width:100%;height:auto;border:1px solid 1px solid #c9ced6\"><figcaption style=\"font-size:0.9em;color:#555;margin-top:6px\">Rear view showing power inlet, gas\/water connectors and shock-absorbing feet.<\/figcaption><\/figure>\n<h3>Frequently asked questions<\/h3>\n<h4>What elements can this AAS determine?<\/h4>\n<p>The series is specified for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. Element-specific detection limits are supplied for Cu and Cd in the datasheet; limits for other elements must be confirmed against your application.<\/p>\n<h4>What is the wavelength range?<\/h4>\n<p>All three models cover 185\u2013900 nm with a 1800 lines\/mm grating blazed at 250 nm.<\/p>\n<h4>How many lamps can be fitted?<\/h4>\n<p>The turret holds eight lamps and can preheat 1\u20134 lamps simultaneously.<\/p>\n<h4>What does the graphite furnace add?<\/h4>\n<p>Graphite furnace atomization extends the instrument to lower mass detection limits \u2014 the datasheet lists Cd \u22641.0 pg (AA1900) and Cd \u22640.8 pg (AA2000), with a temperature range up to 3000 \u00b0C.<\/p>\n<h4>Which background correction is fitted?<\/h4>\n<p>AA1800 and AA2000 specify D\u2082 lamp \u226540-fold (1 Abs) and self-reversal \u226580-fold (1 Abs). AA1900 specifies D\u2082 lamp \u226540-fold (1 Abs).<\/p>\n<h4>What data processing is available?<\/h4>\n<p>Standard curve with six linear\/non-linear fitting methods, standard addition and interpolation; 1\u201330 repeated measurements with average, SD and RSD.<\/p>\n<h4>What power supply is required?<\/h4>\n<p>AC 220 V, 50\/60 Hz for all three models.<\/p>\n<h3>Request a quotation<\/h3>\n<p>Specify your element list, sample matrix, required detection limits and atomization mode (flame only or flame + graphite furnace). BRT will confirm the configuration, accessory set and delivery terms. Contact <strong>info@brt-test.com<\/strong> or WhatsApp <strong>+86 156 0405 7553<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Compare the BRT AA1800, AA1900 and AA2000 atomic absorption spectrophotometer series \u2014 optical performance, flame and graphite furnace data, accessories and physical specifications.<\/p>","protected":false},"featured_media":1917,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[143],"product_tag":[],"class_list":["post-1926","product","type-product","status-publish","has-post-thumbnail","product_cat-atomic-absorption-spectrophotometer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product\/1926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/comments?post=1926"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/media\/1917"}],"wp:attachment":[{"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/media?parent=1926"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1926"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1926"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}