{"id":853,"date":"2026-09-15T09:09:12","date_gmt":"2026-09-15T01:09:12","guid":{"rendered":"https:\/\/brt-testing.com\/?post_type=product&#038;p=853"},"modified":"2026-09-23T14:14:50","modified_gmt":"2026-09-23T06:14:50","slug":"steel-fire-retardant-coating-test-furnace","status":"publish","type":"product","link":"https:\/\/brt-testing.com\/tr\/product\/steel-fire-retardant-coating-test-furnace\/","title":{"rendered":"GTL-50 Steel Structure Fire Retardant Coating Sample Test Furnace"},"content":{"rendered":"<p><!-- 1. Executive Summary & Value Proposition --><\/p>\n<p>The <strong>GTL-50 Steel Structure Fire Retardant Coating Sample Test Furnace <\/strong>is a dedicated laboratory testing instrument developed strictly in accordance with <strong>ISO 834<\/strong>, <strong>BS 476 (Parts 20\/21)<\/strong>, <strong>EN 13381-4\/8<\/strong>, <strong>ASTM E119<\/strong>, <strong>UL 263<\/strong>, and <strong>GB 14907-2018<\/strong> standards. It is engineered to evaluate the fire resistance rating, thermal insulation efficiency, and flame retardancy of fireproof coatings applied to steel plates and structural components.<\/p>\n<p>Featuring a compact 1.6m \u00d7 1.6m \u00d7 1.6m diesel-fueled heating chamber, dual touch screen and wireless PC control, real-time closed-loop temperature and pressure curve tracking (up to 1210\u00b0C \/ 360 min), and automatic thermocouple fault elimination, this high-precision <strong>Fire-Retardant Coating Thermal Insulation Efficiency Test Furnace<\/strong> delivers authoritative test data for paint manufacturers, third-party fire testing laboratories, marine classification bodies, and construction material quality supervision bureaus.<\/p>\n<hr \/>\n<p><!-- 2. Applicable Standards & Test Specifications --><\/p>\n<h3>Steel Structure Fire Retardant Coating Sample Test Furnace Compliance &amp; Standards<\/h3>\n<p>This fire-retardant coating sample test furnace enables certified testing facilities to assess coating performance across global structural fire protection frameworks:<\/p>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<thead>\n<tr style=\"background-color: #f8f9fa;\">\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Standard Code<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Standard Title &amp; Scope<\/th>\n<th style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\">Testing Application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>ISO 834 \/ BS 476-20\/21<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Fire-resistance tests \u2014 Elements of building construction &amp; loadbearing structural elements<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">International benchmark for standard time-temperature fire curve compliance and coating testing<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>EN 13381-8 \/ EN 13381-4<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Test methods for determining the contribution to the fire resistance of structural members (Reactive &amp; Passive protection to steel)<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">European standard for intumescent (reactive) and thick non-intumescent (passive) steel fireproof coatings<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>ASTM E119 \/ UL 263<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Standard Test Methods for Fire Tests of Building Construction and Materials<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">North American fire resistance and thermal insulation evaluations for structural steel coatings<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>GB 14907-2018 &amp; GB\/T 9978-2008<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Fire-retardant coating for steel structures &amp; Fire-resistance tests for building elements<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Mandatory Chinese national standard for thermal insulation efficiency &amp; fire resistance limit testing<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>IMO FTP Code Part 11<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">International Code for Application of Fire Test Procedures \u2014 Structural Fire Protection<\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Fire protection coating evaluations for marine steel structures, deck bulkheads, and offshore platforms<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 3. Key Technological Advantages --><\/p>\n<h3>Technological Features of GTL-50 Fire-Retardant Coating Test Furnace<\/h3>\n<ul>\n<li><strong>Dual Touch Screen &amp; Wireless PC Multi-Station Linkage:<\/strong> Operates via an intuitive standalone onboard touch screen or wireless PC software. Supports multi-furnace synchronization from a single computer terminal and allows centralized data monitoring across network workstations.<\/li>\n<li><strong>High-Efficiency Diesel Spray Burner &amp; Standard Curve Simulation:<\/strong> Equipped with an automatic diesel combustion system (using 0# \/ -10# diesel fuel) capable of following standard time-temperature curves up to 1210\u00b0C over a 360-minute duration (e.g., 60 min @ 925\u00b0C, 180 min @ 1115\u00b0C, 360 min @ 1210\u00b0C).<\/li>\n<li><strong>Automated Closed-Loop Pressure &amp; Temperature Regulation:<\/strong> Maintains a constant furnace pressure of 20 \u00b1 3 Pa (0\u2013100 Pa measurement range) and a tight unexposed surface temperature tolerance within \u00b14\u00b0C, vastly surpassing national standard precision thresholds.<\/li>\n<li><strong>Intelligent Thermocouple Fault Elimination &amp; Flame Protection:<\/strong> Built-in self-diagnostics automatically detect, isolate, and shield damaged thermocouple signals during continuous heating. Features automatic re-ignition protection in the event of accidental flameout during testing.<\/li>\n<li><strong>Automated Post-Test Exhaust Cooling &amp; Power-Off Protection:<\/strong> Includes forced exhaust heat dissipation upon test completion to accelerate turn-around times. Built-in power-off backup programs prevent data loss and equipment damage during sudden electrical interruptions.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 4. Technical Specifications --><\/p>\n<h3>Technical Specifications of Steel Structure Fire Retardant Coating Test Furnace<\/h3>\n<table style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px; width: 35%;\"><strong>Governing Test Standards<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">ISO 834, BS 476-20\/21, EN 13381-4\/8, ASTM E119, UL 263, GB 14907-2018, GB\/T 9978-2008, IMO FTP Code Part 11<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Standard Specimen Dimensions<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">500 mm \u00d7 500 mm \u00d7 6 mm (Coated steel plate)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Heating Fuel &amp; System<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">0# \/ -10# Diesel; full-automatic spray burner assembly<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Programmed Temperature Curves<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">60 min: 925\u00b0C | 120 min: 1050\u00b0C | 180 min: 1115\u00b0C | 240 min: 1150\u00b0C | 300 min: 1180\u00b0C | 360 min: 1210\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Furnace &amp; Surface Thermocouples<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">4 furnace sensors + 2 unexposed surface sensors (Class II K-type sheathed); Tolerance: \u00b14\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Furnace Pressure Control<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Range: 0\u2013100 Pa; Closed-loop constant control: 20 \u00b1 3 Pa<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Airflow Volume &amp; Accuracy<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">0\u201350 m\u00b3\/min; Measurement accuracy: \u2264 \u00b10.5 m\u00b3\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Timer &amp; Data Storage<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">Timing range: 0\u2013360 min (&lt; \u00b12s accuracy); Onboard memory stores &gt;100 test groups<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Power Supply &amp; Consumption<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">AC 220V \u00b110%, 50 Hz; Total Power: 3.0 kW<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #ddd; padding: 8px;\"><strong>Overall Equipment Dimensions<\/strong><\/td>\n<td style=\"border: 1px solid #ddd; padding: 8px;\">1.6 m (L) \u00d7 1.6 m (W) \u00d7 1.6 m (H)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<p><!-- 5. Applications & Workflow --><\/p>\n<h3>System Architecture &amp; Testing Workflow of Fire Retardant Coating Test Furnace<\/h3>\n<p><strong>Standardized Testing Workflow:<\/strong><\/p>\n<ol>\n<li>Apply the steel structure fire-retardant coating to the 500mm \u00d7 500mm \u00d7 6mm standard steel plate specimen and allow it to cure per standard instructions.<\/li>\n<li>Mount the specimen onto the test furnace opening, attaching K-type thermocouples to the unexposed face to measure heat conduction.<\/li>\n<li>Select the target fire-resistance duration (e.g., 180 or 360 minutes) on the touch screen or wireless PC interface.<\/li>\n<li>Trigger the automatic spray burner; the system heats up following the GB 14907 \/ ISO 834 curve while continuously recording furnace pressure and unexposed surface temperature.<\/li>\n<li>Upon test completion, the furnace automatically terminates heating, saves test records, and initiates forced exhaust cooling.<\/li>\n<\/ol>\n<p><strong>Target Customer Applications:<\/strong><\/p>\n<ul>\n<li>Thin, ultra-thin, and thick steel structure fireproof coating manufacturers.<\/li>\n<li>Third-party fire protection product inspection centers and construction quality laboratories.<\/li>\n<li>Chemical engineering and polymer R&amp;D institutes specializing in intumescent flame-retardant coatings.<\/li>\n<li>University civil engineering and fire safety science research centers.<\/li>\n<\/ul>\n<hr \/>\n<p><!-- 6. Frequently Asked Questions (FAQ) --><\/p>\n<h3>Steel Structure Fire Retardant Coating Sample Test Furnace FAQ<\/h3>\n<h4>Q1: What is the main evaluation metric for GB 14907 steel structure coating tests?<\/h4>\n<p><strong>A:<\/strong> The primary metric is the <strong>Thermal Insulation Efficiency \/ Fire Resistance Limit<\/strong>, defined as the time required for the average temperature of the unexposed steel plate to reach a critical limit (typically 500\u00b0C or specified temperature rise) under the standard fire time-temperature curve.<\/p>\n<h4>Q2: How does the wireless PC control benefit multi-furnace laboratory operations?<\/h4>\n<p><strong>A:<\/strong> Wireless linkage enables a single central computer terminal to wirelessly connect to and synchronously control multiple GTL-50 test furnaces. Laboratories can execute simultaneous batch tests, collect live data, and archive reports without extensive cabling.<\/p>\n<h4>Q3: What safety mechanisms are built into the diesel combustion system?<\/h4>\n<p><strong>A:<\/strong> The GTL-50 includes automatic flameout detection with auto re-ignition capabilities, power-off memory protection, and over-temperature safety cut-offs to guarantee safe, unattended laboratory testing.<\/p>","protected":false},"excerpt":{"rendered":"<p><b data-path-to-node=\"7,0\" data-index-in-node=\"0\">GTL-50 Steel Structure Fire Retardant Coating Sample Test Furnace<\/b> strictly meets <strong>ISO 834<\/strong>, <strong>BS 476 (Parts 20\/21)<\/strong>, <strong>EN 13381-4\/8<\/strong>, <strong>ASTM E119<\/strong>, <strong>UL 263<\/strong>, and <strong>GB 14907-2018<\/strong> standards. \u00a0Features touch screen &amp; wireless PC dual control, diesel spray heating up to 1210\u00b0C \/ 360 min, constant 20\u00b13Pa furnace pressure control, auto thermocouple fault elimination, and automatic curve logging for steel coating fire resistance evaluation.<\/p>","protected":false},"featured_media":854,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[117],"product_cat":[24],"product_tag":[],"class_list":["post-853","product","type-product","status-publish","has-post-thumbnail","product_brand-brt-testing","product_cat-fire-flame-testing-equipment","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product\/853","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/comments?post=853"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/media\/854"}],"wp:attachment":[{"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/media?parent=853"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product_brand?post=853"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product_cat?post=853"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/brt-testing.com\/tr\/wp-json\/wp\/v2\/product_tag?post=853"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}