Welcome to BRT Testing’s Fire & Flame Testing Equipment category. We provide a comprehensive range of advanced flammability testing instruments designed to evaluate the fire safety, ignition resistance, and burning behavior of various materials. Our equipment complies with global standards such as ISO, IEC, UL, and ASTM, ensuring precise and reliable results for laboratories, R&D centers, and quality control departments across industries like electronics, Kunststoffe, Baustoffe, and automotive components.
-
SPCZ-05 Horizontal & Vertical Combustion Tester strictly complies with UL 94, GB/T 2408-2021, and IEC 60950-1 Standards. Features a PLC touchscreen controller, 50W Bunsen burner with auto-retraction, motorized 4-way sample positioning, automatic gas cut-off, and internal data storage for plastic, Gummi, and electronics flammability testing.
-
Der Horizontaler Feuerwiderstandsprüfofen NH-XW is a full-scale industrial testing solution engineered for precast floor slabs, steel beams, concrete decks, and intumescent coatings. Built with a spacious 4.2m × 3.0m × 1.5m combustion chamber, it fully complies with global structural fire safety standards including ISO 834, IN 1363/1365, BS 476, ASTM E119 / UL 263, und GB/T 9978.
- Multi-Standard Compliance: Built-in dynamic temperature-curve tracking for ISO, IN, BS, ASTM/UL, and GB standards.
- Precision Pressure Control: Closed-loop micro-positive furnace pressure control within ±2 Pa Genauigkeit.
- Rapid Thermal Response: 8 proportional LPG burners deliver up to 1300°C maximum working temperature with efficient < 0.5h cool-down.
- Operator Safety First: Equipped with 400°C smoke filtration, high-voltage auto-ignition, and automatic emergency gas cut-off interlocks (>100 Pa).
✓ Trusted by 3rd-party testing institutes, structural coating manufacturers, and research centers worldwide. Request an instant quotation or technical proposal today!
-
ZXLR Kegelkalorimeter (Building Material Heat Release Rate Fire Test Machine) strictly complies with ISO 5660-1, GB/T 16172-2026, and ASTM E1354 standards. Features a 5000W radiant cone heater (0–100 kW/m²), 0.1g thermally protected weighing system, automated program shield, and integrated gas analysis for HRR, mass loss, Rauch, and CO/CO₂ toxic gas evaluation.
-
JYZS-10 Oxygen Index Tester meets ISO 4589-1/2, GB/T 2406.2, ASTM D2863, BS 2782-1 (Verfahren 141), JIS K 7201-2, Und NES 715 Standards. Features ±0.1% high-precision digital oxygen analyzer, <5s sensor response, dual gas pressure & flow regulation, 75mm clear glass chimney with 40±2 mm/s constant airflow, and compact 50W desktop design for plastic, Kabel, Schaum, and textile LOI flame retardancy testing.
-
JRZ10 Bruttoverbrennungswärmetester für Baustoffe wird strikt eingehalten ISO 1716:2018, IN 13501-1 (Euroclass A1/A2), GB/T 14402-2026, ASTM D5865, Und ASTM D240 Standards. Features an ultra-fine 0.0001°C temperature resolution, double-layer 35L/2.3L water tank, precision volume balancing (<0.5g error), imported circulation stirrer, and dedicated Windows software for automated calorific value testing.
-
JCKR Building Material Combustibility Test Apparatus wird strikt eingehalten ISO 11925-2:2026, IN 13501-1 (Euroclass B/C/D/E), GB/T 8626, AUS 4102-1 (B2), Und IN 13238 Standards. Features a 1.5mm stainless steel cabinet, 7-inch industrial touchscreen, motorized burner 45° positioning, high-voltage auto-ignition with 5s/15s/30s timers, and a complete mounting accessory kit for Class B1/B2 fire classification.
-
Vertikales Flammenprüfgerät CS380 mit gebündeltem Kabel wird strikt eingehalten IEC 60332-3-10 / IEC 60332-3-21~25 (Kategorien A F/R, A, B, C, D), GB/T 18380,31 ~ 36, UL 1685, IN 45545-2, Und IN 50399 Standards. Verfügt über eine 1m×2m×4m Mineralwolle-Isolierung 304 Edelstahlkammer, SPS-Touchscreen-Steuerung, elektrischer Probenkran, Doppel-Propan-Bandbrenner mit Venturi-Gasmischer, und automatische Gasabschaltung für gebündelte Drähte & Feuerwiderstandsprüfung optischer Kabel.
-
GTL-50-Stahlkonstruktion, feuerhemmende Beschichtung, Mustertestofen strictly meets ISO 834, BS 476 (Parts 20/21), IN 13381-4/8, ASTM E119, UL 263, Und GB 14907-2018 Standards. Features touch screen & wireless PC dual control, diesel spray heating up to 1210°C / 360 min, constant 20±3Pa furnace pressure control, auto thermocouple fault elimination, and automatic curve logging for steel coating fire resistance evaluation.
-
CYD-Rauchtoxizitätstestausrüstung wird strikt eingehalten GB/T 20285-2006, AUS 53436, BS EN 17084, ISO 19702, Und JIS A 1321 protocols. Features an annular furnace powered by Swedish Kanthal wire, precision stepper motor drive (10±0.1 mm/min), zero-leakage quartz pipeline assembly, and 10-channel Hall-sensor mouse activity tracking for automated material smoke hazard classification testing.
-
NH-016 Cable Fire Resistance Tester ist eine hochpräzise, heavy-duty laboratory system designed to evaluate the circuit integrity, thermal endurance, and electrical survival of power, Daten, and optical cables under severe fire conditions up to 1000°C (with optional water spray & mechanical shock).
Key Features:
- Multi-Standard Compliance: Engineered strictly according to IEC 60331 (Parts 1/2/11/21/23/25), BS 6387:2013, BS 8491, IN 50200, Und GB/T 19216.
- Heavy-Duty Chamber: Integrated 3m × 3m × 3m 304 stainless steel insulated combustion chamber with high-temperature fireproof lining.
- 5-Channel Independent Electrical Load: Precise voltage and current control (0–1000V / 0.1–3A) per channel.
- Precision Flame & Gas Control: Dual propane ribbon burners equipped with Mass Flow Controllers (MFC) for accurate temperature regulation.
- Automated Control: Intuitive PLC touch-screen display for seamless operation, test automation, and real-time data logging.
- Zielanwendungen: Ideal for wire & cable manufacturers, Brandprüfstellen Dritter, rail transit, Meeresklassifikationsgesellschaften, and research institutes.
-
Vertikaler integrierter Feuerwiderstandsprüfofen NH-XL strictly complies with GB/T 9978, GB 12955-2024, GB 16809-2024, und ISO 834-1 Standards. Features a 3.0m × 3.0m × 1.2m cavity, lightweight high-alumina zirconia fiber suspended lining (up to 1300°C), 8 proportional gas burners, closed-loop pressure control, and automated PC data logging for fire doors, windows, shutters, and partition wall integrity & insulation testing.
-
Der JYMD Building Materials Rauchdichtetester is a professional static smoke generation testing apparatus designed for plastics, Polymere, and synthetic building materials. Strictly engineered according to ASTM D2843 Und GB/T 8627-2007, it provides precise, automated measurement of Maximum Smoke Density (MSD) and Smoke Density Rating (SDR).