Pipe hydrostatic pressure tester engineered for long-term constant-pressure Und instantaneous burst testing of thermoplastic pipes from DN16 to DN1600. The GJ16C pairs a 3-channel modular pressure control unit with a 304 stainless steel constant-temperature water tank and patented Type A radial-seal fixtures — delivering 0.4–16 MPa control, ±0.1% timing accuracy and full ISO 1167/ ISO 9080:2012 / ASTM D1598 / ASTM D1599 compliance. Every channel runs and stores data independently, so a failure on one station never interrupts the others.
-
WD-50H Microcomputer-Controlled Pipe Ring Stiffness & Flexibilitätsprüfmaschine strictly complies with ISO 9969, ISO 9967, IN 13476-1, and ASTM D2412 standards. Features a heavy-duty 50kN 4-column gantry frame, Klasse 0.5 Genauigkeit (±0.5%), dual spoke load sensors, an internal diameter extensometer (DN180–DN1500 mm), and AC servo closed-loop control for pipe stiffness, flexibility, and creep ratio testing.
-
BRT-1150V Sichtbares Spektralphotometer is a lightweight 8 kg benchtop instrument featuring a 3.5-inch TFT color LCD screen, 325–1050 nm visible range, 4 nm bandwidth, Und 1200 lines/mm holographic grating. Equipped with a long-life tungsten lamp, low-noise wavelength drive, A/T/E/C/F testing modes, 200-dataset memory, 5–100 mm cuvette flexibility, USB connectivity, and LPT printer support for routine laboratory colorimetric and concentration analysis.
-
Der Einzelner brennender Gegenstand (SBI) Testausrüstung (JCDT Series) is a fully automated, high-precision fire reaction test system designed to evaluate heat release, smoke growth, and flammability of building materials. Built strictly to meet IN 13823, IN 13501-1 (Euroclass A2, B, C, D), Und GB/T 20284 Standards.
- Precision Gas Analysis Rack: Equipped with a paramagnetic O₂ analyzer (±0.1%) and NDIR CO₂ analyzer for exact HRR & FIGRA measurements.
- Automated PC DAQ Software: One-click test control with real-time automated calculation of THR₆₀₀ₛ, SMOGRA, and TSP₆₀₀ₛ.
- Double-Insulated J-Duct & Hood: Maintains consistent airflow (0.50–0.65 m³/s) and eliminates thermal loss during combustion.
- AUS 50055 Optical Smoke System: High-stability white-light attenuation optics for continuous light transmittance assessment.
✓ Cost-effective Euroclass testing solution for certification bodies, third-party labs, and building product manufacturers. Contact us for full technical specifications & instant pricing!
-
High-precision EN ISO 1182, ISO 1182:2020, GB/T 5464-2026, GB 8624-2025, IN 13238, BS 476-4, ASTM E136 Non-Combustibility Tester for evaluating building material fire performance at 750°C. Fully compliant with IMO FTP Part 1 and ASTM E2652, featuring automated PID temperature control, multi-point K-type thermocouples, real-time DAQ software, and Euroclass A1/A2 pass/fail analysis.
-
FHDM-Prüfgerät für flammhemmendes Holz strictly designed for GA/T 42.1 (Referencing ASTM E160 & GB/T 8625) wood crib fire resistance testing. Features automatic motorized burner positioning, precise 310°C temperature control, digital timing (±0.1s accuracy), and dual NG/LPG fuel compatibility for evaluating flaming duration and mass loss rate in fire-treated lumber (>20mm thickness).
-
PDCL-01 Strahlungswärmeflusstester strictly designed for ISO 9239-1, ASTM E648, IN ISO 9239-1, NFPA 253, GB/T 11785-2005 flooring fire reaction testing. Features a custom 304 stainless steel radiant burner, 0–15 kW/m² heat flux meter, ±0.1 m/s anemometer for 2.5 m/s steady airflow, split stainless steel cabinet, and multi-gas compatibility (Methane/Propane/LPG) to accurately determine critical radiant flux in carpets, wood, PVC, and composite floorings.
-
ZBY Combustion Tester strictly engineered to ASTM D777, GB/T 14656-2009 for flame-retardant paper and paperboard flammability testing (thickness ≤1.6mm). Features an MCU automated control module, ±0.01s precision timing, 0°–45° multi-angle adjustable Bunsen burner, 15–175mm flame height control, and an enclosed observation cabinet for measuring afterflame and afterglow duration.
-
JYZS-20 Oxygen Index Tester strictly complies with ISO 4589-2, ASTM D2863, BS 2782-1, NES 715, GB/T 2406, GB/T 5454 Standards. Features automated touchscreen gas regulation, closed-loop concentration correction (±0.1% accuracy), an imported 0–100% oxygen sensor (<5s response), dual specimen holders for rigid/flexible polymers, and a 40±2mm/s airflow combustion column for precise Limiting Oxygen Index (LOI) testing.
-
FCZ-50 Textile Vertical Flammability Tester wird strikt eingehalten ASTM D6413, 16 CFR Teil 1615/1616, ISO 6940/6941, BS EN ISO 15025, Und GB/T 5455-2014 für die Prüfung der vertikalen Feuerbeständigkeit von Stoffen. Verfügt über ein MCGS-Farb-Touchscreen-Bedienfeld, zwei vorprogrammierte Testmodi (Zustand A & B), 0.1s Timer-Auflösung, Gasdrucküberwachung in Echtzeit, und ein kompletter Satz Standard-Gegengewichte (54.5g–453,6g) zur Messung der Nachbrennzeit, Nachglühzeit, und beschädigte Länge.
-
SPCZ-06 Kunststoffschaum vertikal & Horizontaler Brenntester wird strikt eingehalten ISO 9772 & ASTM D4986 Standards. Features dual horizontal and vertical testing configurations, touchscreen & wireless PC control, 0.1s/1mm high-precision measurement, visual gas pressure monitoring, 9.5mm wing-top Bunsen burner, and automated exhaust cooling for cellular and rigid foam flammability rating.
-
JCNR-60 Prüfgerät für schwer brennbare Baustoffe wird strikt eingehalten AUS 4102-15/16 (Brandschacht Test) Und GB/T 8625-2026. Features a vertical shaft furnace, constant 20°C air supply unit, 10-minute fixed methane flame exposure with 540°C surface heat load, automated PC flue gas temperature tracking with 200°C auto test stop, and precision gas flow control for construction material B1 fire certification.
-
Der JYMD Building Materials Rauchdichtetester is a professional static smoke generation testing apparatus designed for plastics, Polymere, and synthetic building materials. Strictly engineered according to ASTM D2843 Und GB/T 8627-2007, it provides precise, automated measurement of Maximum Smoke Density (MSD) and Smoke Density Rating (SDR).
-
NH-XL Vertical Integrated Fire Resistance Test Furnace strictly complies with GB/T 9978, GB 12955-2024, GB 16809-2024, und ISO 834-1 Standards. Features a 3.0m × 3.0m × 1.2m cavity, lightweight high-alumina zirconia fiber suspended lining (up to 1300°C), 8 proportional gas burners, closed-loop pressure control, and automated PC data logging for fire doors, windows, shutters, and partition wall integrity & insulation testing.
-
NH-016 Cable Fire Resistance Tester ist eine hochpräzise, heavy-duty laboratory system designed to evaluate the circuit integrity, thermal endurance, and electrical survival of power, Daten, and optical cables under severe fire conditions up to 1000°C (with optional water spray & mechanical shock).
Key Features:
- Multi-Standard Compliance: Engineered strictly according to IEC 60331 (Parts 1/2/11/21/23/25), BS 6387:2013, BS 8491, IN 50200, Und GB/T 19216.
- Heavy-Duty Chamber: Integrated 3m × 3m × 3m 304 stainless steel insulated combustion chamber with high-temperature fireproof lining.
- 5-Channel Independent Electrical Load: Precise voltage and current control (0–1000V / 0.1–3A) per channel.
- Precision Flame & Gas Control: Dual propane ribbon burners equipped with Mass Flow Controllers (MFC) for accurate temperature regulation.
- Automated Control: Intuitive PLC touch-screen display for seamless operation, test automation, and real-time data logging.
- Zielanwendungen: Ideal for wire & cable manufacturers, third-party fire testing agencies, rail transit, marine classification societies, and research institutes.
-
CYD-Rauchtoxizitätstestausrüstung wird strikt eingehalten GB/T 20285-2006, AUS 53436, BS EN 17084, ISO 19702, Und JIS A 1321 protocols. Features an annular furnace powered by Swedish Kanthal wire, precision stepper motor drive (10±0.1 mm/min), zero-leakage quartz pipeline assembly, and 10-channel Hall-sensor mouse activity tracking for automated material smoke hazard classification testing.
-
GTL-50-Stahlkonstruktion, feuerhemmende Beschichtung, Mustertestofen strictly meets ISO 834, BS 476 (Parts 20/21), IN 13381-4/8, ASTM E119, UL 263, Und GB 14907-2018 Standards. Features touch screen & wireless PC dual control, diesel spray heating up to 1210°C / 360 min, constant 20±3Pa furnace pressure control, auto thermocouple fault elimination, and automatic curve logging for steel coating fire resistance evaluation.
-
Vertikales Flammenprüfgerät CS380 mit gebündeltem Kabel wird strikt eingehalten IEC 60332-3-10 / IEC 60332-3-21~25 (Categories A F/R, A, B, C, D), GB/T 18380.31~36, UL 1685, IN 45545-2, Und IN 50399 Standards. Features a 1m×2m×4m mineral-wool-insulated 304 stainless steel chamber, PLC touchscreen control, electric specimen crane, dual propane ribbon burners with Venturi gas mixers, and automated gas shut-off for bundled wire & optical cable fire resistance testing.
-
JCKR Building Material Combustibility Test Apparatus wird strikt eingehalten ISO 11925-2:2026, IN 13501-1 (Euroclass B/C/D/E), GB/T 8626, AUS 4102-1 (B2), Und IN 13238 Standards. Features a 1.5mm stainless steel cabinet, 7-inch industrial touchscreen, motorized burner 45° positioning, high-voltage auto-ignition with 5s/15s/30s timers, and a complete mounting accessory kit for Class B1/B2 fire classification.
-
JRZ10 Bruttoverbrennungswärmetester für Baustoffe wird strikt eingehalten ISO 1716:2018, IN 13501-1 (Euroclass A1/A2), GB/T 14402-2026, ASTM D5865, Und ASTM D240 Standards. Features an ultra-fine 0.0001°C temperature resolution, double-layer 35L/2.3L water tank, precision volume balancing (<0.5g error), imported circulation stirrer, and dedicated Windows software for automated calorific value testing.
-
JYZS-10 Oxygen Index Tester meets ISO 4589-1/2, GB/T 2406.2, ASTM D2863, BS 2782-1 (Verfahren 141), JIS K 7201-2, Und NES 715 Standards. Features ±0.1% high-precision digital oxygen analyzer, <5s sensor response, dual gas pressure & flow regulation, 75mm clear glass chimney with 40±2 mm/s constant airflow, and compact 50W desktop design for plastic, Kabel, foam, and textile LOI flame retardancy testing.
-
ZXLR Kegelkalorimeter (Building Material Heat Release Rate Fire Test Machine) strictly complies with ISO 5660-1, GB/T 16172-2026, and ASTM E1354 standards. Features a 5000W radiant cone heater (0–100 kW/m²), 0.1g thermally protected weighing system, automated program shield, and integrated gas analysis for HRR, mass loss, Rauch, and CO/CO₂ toxic gas evaluation.
-
Der NH-XW Horizontal Fire Resistance Test Furnace is a full-scale industrial testing solution engineered for precast floor slabs, steel beams, concrete decks, and intumescent coatings. Built with a spacious 4.2m × 3.0m × 1.5m combustion chamber, it fully complies with global structural fire safety standards including ISO 834, IN 1363/1365, BS 476, ASTM E119 / UL 263, und GB/T 9978.
- Multi-Standard Compliance: Built-in dynamic temperature-curve tracking for ISO, IN, BS, ASTM/UL, and GB standards.
- Precision Pressure Control: Closed-loop micro-positive furnace pressure control within ±2 Pa Genauigkeit.
- Rapid Thermal Response: 8 proportional LPG burners deliver up to 1300°C maximum working temperature with efficient < 0.5h cool-down.
- Operator Safety First: Equipped with 400°C smoke filtration, high-voltage auto-ignition, and automatic emergency gas cut-off interlocks (>100 Pa).
✓ Trusted by 3rd-party testing institutes, structural coating manufacturers, and research centers worldwide. Request an instant quotation or technical proposal today!
-
SPCZ-05 Horizontal & Vertical Combustion Tester strictly complies with UL 94, GB/T 2408-2021, and IEC 60950-1 Standards. Features a PLC touchscreen controller, 50W Bunsen burner with auto-retraction, motorized 4-way sample positioning, automatic gas cut-off, and internal data storage for plastic, Gummi, and electronics flammability testing.