Pipe hydrostatic pressure tester engineered for long-term constant-pressure Und instantaneous burst testing of thermoplastic pipes from DN16 to DN1600. The GJ16C pairs a 3-channel modular pressure control unit with a 304 stainless steel constant-temperature water tank and patented Type A radial-seal fixtures — delivering 0.4–16 MPa control, ±0.1% timing accuracy and full ISO 1167/ ISO 9080:2012 / ASTM D1598 / ASTM D1599 compliance. Every channel runs and stores data independently, so a failure on one station never interrupts the others.
-
WD-50H Microcomputer-Controlled Pipe Ring Stiffness & Flexibilitätsprüfmaschine strictly complies with ISO 9969, ISO 9967, IN 13476-1, and ASTM D2412 standards. Features a heavy-duty 50kN 4-column gantry frame, Klasse 0.5 Genauigkeit (±0.5%), dual spoke load sensors, an internal diameter extensometer (DN180–DN1500 mm), and AC servo closed-loop control for pipe stiffness, flexibility, and creep ratio testing.
-
BRT-1150V Sichtbares Spektralphotometer is a lightweight 8 kg benchtop instrument featuring a 3.5-inch TFT color LCD screen, 325–1050 nm visible range, 4 nm bandwidth, Und 1200 lines/mm holographic grating. Equipped with a long-life tungsten lamp, low-noise wavelength drive, A/T/E/C/F testing modes, 200-dataset memory, 5–100 mm cuvette flexibility, USB connectivity, and LPT printer support for routine laboratory colorimetric and concentration analysis.
-
Der Einzelner brennender Gegenstand (SBI) Testausrüstung (JCDT Series) is a fully automated, high-precision fire reaction test system designed to evaluate heat release, smoke growth, and flammability of building materials. Built strictly to meet IN 13823, IN 13501-1 (Euroclass A2, B, C, D), Und GB/T 20284 Standards.
- Precision Gas Analysis Rack: Equipped with a paramagnetic O₂ analyzer (±0.1%) and NDIR CO₂ analyzer for exact HRR & FIGRA measurements.
- Automated PC DAQ Software: One-click test control with real-time automated calculation of THR₆₀₀ₛ, SMOGRA, and TSP₆₀₀ₛ.
- Double-Insulated J-Duct & Hood: Maintains consistent airflow (0.50–0.65 m³/s) and eliminates thermal loss during combustion.
- AUS 50055 Optical Smoke System: High-stability white-light attenuation optics for continuous light transmittance assessment.
✓ Cost-effective Euroclass testing solution for certification bodies, third-party labs, and building product manufacturers. Contact us for full technical specifications & instant pricing!
-
High-precision EN ISO 1182, ISO 1182:2020, GB/T 5464-2026, GB 8624-2025, IN 13238, BS 476-4, ASTM E136 Non-Combustibility Tester for evaluating building material fire performance at 750°C. Fully compliant with IMO FTP Part 1 and ASTM E2652, featuring automated PID temperature control, multi-point K-type thermocouples, real-time DAQ software, and Euroclass A1/A2 pass/fail analysis.
-
FHDM-Prüfgerät für flammhemmendes Holz strictly designed for GA/T 42.1 (Referencing ASTM E160 & GB/T 8625) wood crib fire resistance testing. Features automatic motorized burner positioning, precise 310°C temperature control, digital timing (±0.1s accuracy), and dual NG/LPG fuel compatibility for evaluating flaming duration and mass loss rate in fire-treated lumber (>20mm thickness).
-
PDCL-01 Strahlungswärmeflusstester strictly designed for ISO 9239-1, ASTM E648, IN ISO 9239-1, NFPA 253, GB/T 11785-2005 flooring fire reaction testing. Features a custom 304 stainless steel radiant burner, 0–15 kW/m² heat flux meter, ±0.1 m/s anemometer for 2.5 m/s steady airflow, split stainless steel cabinet, and multi-gas compatibility (Methane/Propane/LPG) to accurately determine critical radiant flux in carpets, wood, PVC, and composite floorings.
-
ZBY Combustion Tester strictly engineered to ASTM D777, GB/T 14656-2009 for flame-retardant paper and paperboard flammability testing (thickness ≤1.6mm). Features an MCU automated control module, ±0.01s precision timing, 0°–45° multi-angle adjustable Bunsen burner, 15–175mm flame height control, and an enclosed observation cabinet for measuring afterflame and afterglow duration.
-
JYZS-20 Oxygen Index Tester strictly complies with ISO 4589-2, ASTM D2863, BS 2782-1, NES 715, GB/T 2406, GB/T 5454 Standards. Features automated touchscreen gas regulation, closed-loop concentration correction (±0.1% accuracy), an imported 0–100% oxygen sensor (<5s response), dual specimen holders for rigid/flexible polymers, and a 40±2mm/s airflow combustion column for precise Limiting Oxygen Index (LOI) Testen.
-
FCZ-50 Textile Vertical Flammability Tester wird strikt eingehalten ASTM D6413, 16 CFR Teil 1615/1616, ISO 6940/6941, BS EN ISO 15025, Und GB/T 5455-2014 für die Prüfung der vertikalen Feuerbeständigkeit von Stoffen. Verfügt über ein MCGS-Farb-Touchscreen-Bedienfeld, zwei vorprogrammierte Testmodi (Zustand A & B), 0.1s Timer-Auflösung, Gasdrucküberwachung in Echtzeit, und ein kompletter Satz Standard-Gegengewichte (54.5g–453,6g) zur Messung der Nachbrennzeit, Nachglühzeit, und beschädigte Länge.
-
SPCZ-06 Kunststoffschaum vertikal & Horizontaler Brenntester wird strikt eingehalten ISO 9772 & ASTM D4986 Standards. Features dual horizontal and vertical testing configurations, touchscreen & wireless PC control, 0.1s/1mm high-precision measurement, visual gas pressure monitoring, 9.5mm wing-top Bunsen burner, and automated exhaust cooling for cellular and rigid foam flammability rating.
-
JCNR-60 Prüfgerät für schwer brennbare Baustoffe wird strikt eingehalten AUS 4102-15/16 (Brandschacht Test) Und GB/T 8625-2026. Verfügt über einen vertikalen Schachtofen, Luftversorgungseinheit mit konstanter Temperatur von 20 °C, 10-Minutenlange, feste Methanflammeneinwirkung mit einer Oberflächenwärmebelastung von 540 °C, Automatische PC-Rauchgastemperaturverfolgung mit automatischem Teststopp bei 200 °C, und präzise Gasdurchflussregelung für die B1-Brandschutzzertifizierung des Baumaterials.