BRT-1800UV UV-Vis-Spektrophotometer is a single-beam benchtop instrument featuring an extended 190–1100 nm spectral range, narrow 2 nm bandwidth, 1200 lines/mm holographic grating, and ≤0.2 nm wavelength repeatability. Equipped with a 128×64 LCD display, dual tungsten/deuterium lamps, 100-curve/200-dataset memory, USB PC connectivity, and LPT printer output, it delivers precise photometric, quantitative, kinetic, and DNA/protein assays.
Der BRT-1800UV UV-Vis-Spektrophotometer is an advanced single-beam laboratory analytical instrument designed for high-resolution photometric analysis, quantitative determination, kinetics, and molecular bio-assays. Engineered for pharmaceutical quality control, life science research, molecular biology, and chemical testing laboratories, it delivers an extended spectral range of 190 nm to 1100 nm with a narrow 2 nm spectral bandwidth, ±0.5 nm wavelength accuracy, and ≤0.2 nm wavelength repeatability.
Featuring a high-grade Czerny-Turner optical system with a 1200 lines/mm holographic grating, imported deuterium and tungsten halogen light sources, and a sensitive photocell detector, this high-precision UV-Vis-Spektrophotometer guarantees exceptional photometric accuracy (±0.3%T) and low stray light. Equipped with a 128×64 dot-matrix LCD display, onboard memory for 100 standard curves and 200 test datasets, automatic startup self-calibration, and high-speed USB PC software connectivity, the BRT-1800UV provides complete analytical versatility for DNA/protein quantification and full-spectrum scanning.
UV Vis Spectrophotometer Measurement & Analysis Capabilities
This high-resolution UV/Vis analytical instrument provides comprehensive multi-mode testing capabilities for liquid, biological, and chemical samples:
| Analysis Mode | Methodology & Operational Scope | Primäre Testanwendung |
|---|---|---|
| Photometrisch & Spectrum Scan | Direct measurement of Absorbance (Abs), Transmittance (%T), and Energy across fixed wavelengths or full 190–1100 nm continuous scanning (via PC software) | Raw material verification, optical density profiling, and full spectral peak characterization |
| Quantitative Concentration Profiling | Single-point coefficient calculations ($C = KA + B$ / $A = KC + B$) or multi-point linear regression fitting using up to 9 standard samples | Pharmaceutical active ingredient assays, chemical solution concentration, and environmental water analysis |
| Kinetics & Bio-Molecular Testing (PC Software) | Time-course kinetic curve tracking with dynamic coordinate scaling, multi-wavelength testing, and specialized DNA/protein ratio profiling (260/280 nm) | Enzyme activity kinetics, nucleic acid purity determination, protein concentration, and degradation tracking |
Technological Features of BRT-1800UV UV Vis Spectrophotometer
- Narrow 2 nm Spectral Bandwidth & Extended 190–1100 nm SpectrumDelivers tight 2 nm optical resolution across an expanded UV-Vis-NIR spectrum, ideal for distinguishing closely spaced absorption peaks in complex biological and chemical matrices.
- High Wavelength Precision (±0.5 nm Accuracy, ≤0.2 nm Repeatability)Ensures exact wavelength positioning with a 0.1 nm resolution readout for superior baseline stability and reproducible experimental data.
- 128×64 Dot-Matrix LCD & Membrane KeypadDisplays dynamic curve graphics, regression equations, and menu structures directly on-screen, paired with a tactile numeric keypad for fast parameter input.
- Self-Calibration & Permanent Baseline MemoryAutomates wavelength zeroing, dark current calibration, and lamp switching without requiring manual recalibration upon every system restart.
- Spacious Sample Chamber (5 mm bis 100 mm Cuvette Range)Accommodates cell holders for optical pathlengths from 5 mm up to 100 mm, enabling flexible setup for both trace biological samples and diluted environmental solutions.
- USB PC Software & LPT Printer OutputFeatures high-speed USB connectivity for PC-driven full-spectrum scanning and DNA/protein assays, alongside a parallel printer port for direct report output.
Technical Specifications of UV Vis Spectrophotometer
| Produktmodell | BRT-1800UV UV-Vis-Spektrophotometer |
| Optical System & Grating | Single Beam, 1200 lines/mm Holographic Grating |
| Wavelength Spectrum & Bandwidth | 190 nm to 1100 nm; Spectral Bandwidth: 2 nm; Wavelength Resolution: 0.1 nm |
| Wavelength Accuracy & Wiederholbarkeit | Accuracy: ±0.5 nm; Wiederholbarkeit: ≤0.2 nm |
| Photometric Range & Accuracy | 0 to 200%T, -0.301 Zu 3.000 Abs, -9999 Zu 9999 C; Transmittance Accuracy: ±0.3%T |
| Light Sources & Detektor | Tungsten Halogen Lamp & Imported Deuterium Lamp; High-Sensitivity Silicon Photocell |
| Data Storage & Connectivity | Stores 100 Curves & 200 Datasets; USB PC Interface, LPT Parallel Printer Port |
| Abmessungen & Instrument Weight | 490 × 370 × 180 mm (W × D × H); Total Weight: 14 kg (33.07 lb) |
Standard Package Accessories Included
- Main Host Unit: BRT-1800UV UV-Vis-Spektrophotometer (1 unit).
- Quartz Cuvettes: 10 mm Standard Quartz Cuvettes (2 pcs for UV spectrum analysis).
- Glass Cuvettes: 10 mm Standard Glass Cuvettes (4 pcs for Visible spectrum analysis).
- Sample Cell Holder: Multi-Position Standard Cell Holder.
- Leistung & Data Connectivity: AC Power Cable, USB Interface Connection Cable.
- Dokumentation & Software: Operating Instruction Manual, Certificate of Conformity, Warranty Card.
Test-Workflow & Zielanwendungen
Standardisierter Testworkflow:
- Power on the BRT-1800UV; allow the microcomputer to run self-testing, dark current zeroing, and wavelength initialization.
- Select Photometric, Quantitative, or Kinetic mode from the 128×64 dot-matrix LCD menu.
- Insert a reference solvent blank in the cell holder and trigger auto 0A / 100%T baseline calibration.
- Place sample cuvettes into the optical path to execute single-wavelength tests or load PC software via USB for DNA/protein quantification and full spectrum scanning.
- Store standard curves (bis zu 100) and data (bis zu 200 sets) to onboard memory, transmit to PC analysis software, or print direct analytical reports via the parallel port.
Zielkundenanwendungen:
- Molecular biology and biochemistry laboratories (DNA, RNA, and protein quantification at 260/280 nm).
- Pharmaceutical manufacturing QA/QC labs and active pharmaceutical ingredient (API) assay facilities.
- Environmental protection agencies (water purity, heavy metal concentration, COD, and nitrate analysis).
- Academic research institutions, university chemistry departments, and food safety inspection labs.
UV Vis Spectrophotometer FAQ
Q1: What is the main advantage of a 2 nm narrow spectral bandwidth on the BRT-1800UV?
A: A 2 nm spectral bandwidth provides significantly higher optical resolution than standard 4 nm instruments. This allows for sharper peak resolution, cleaner separation of overlapping absorption bands, and superior accuracy during quantitative biological and pharmaceutical assays.
Q2: Can the BRT-1800UV perform DNA and protein purity testing without a PC?
A: While basic photometric and quantitative tests can be run standalone using the 128×64 LCD screen, connecting the BRT-1800UV to a PC via USB with the included software enables automated DNA/protein ratio calculations (260/280 nm), kinetics, and full spectral scanning.
Q3: How does the auto-calibration feature benefit daily testing?
A: The instrument automatically calibrates wavelength positions and saves dark current zeroing data during startup, eliminating time-consuming manual calibration before routine testing routines.











Rezensionen
Es gibt noch keine Rezensionen.