• LC-400 CNC-Fallgewichts-Schlagprüfgerät complies with ISO 3127, GB/T 14152, and ASTM D2444 standards. Features CNC height control (500–2000mm), automatic zero calibration, an anti-rebound secondary impact prevention catch, a dual-column frame, and 120° V-block fixtures for DN20–DN400mm plastic pipe external impact testing.
  • JYZS-20 Oxygen Index Tester strictly complies with ISO 4589-2, ASTM D2863, BS 2782-1, NES 715, GB/T 2406, GB/T 5454 Standards. Features automated touchscreen gas regulation, closed-loop concentration correction (±0.1% accuracy), an imported 0–100% oxygen sensor (<5s response), dual specimen holders for rigid/flexible polymers, and a 40±2mm/s airflow combustion column for precise Limiting Oxygen Index (LOI) testing.
  • JYZS-10 Oxygen Index Tester meets ISO 4589-1/2, GB/T 2406.2, ASTM D2863, BS 2782-1 (Verfahren 141), JIS K 7201-2, Und NES 715 Standards. Features ±0.1% high-precision digital oxygen analyzer, <5s sensor response, dual gas pressure & flow regulation, 75mm clear glass chimney with 40±2 mm/s constant airflow, and compact 50W desktop design for plastic, Kabel, foam, and textile LOI flame retardancy testing.
  • Der JYMD Building Materials Rauchdichtetester is a professional static smoke generation testing apparatus designed for plastics, Polymere, and synthetic building materials. Strictly engineered according to ASTM D2843 Und GB/T 8627-2007, it provides precise, automated measurement of Maximum Smoke Density (MSD) and Smoke Density Rating (SDR).
  • JRZ10 Bruttoverbrennungswärmetester für Baustoffe wird strikt eingehalten ISO 1716:2018, IN 13501-1 (Euroclass A1/A2), GB/T 14402-2026, ASTM D5865, Und ASTM D240 Standards. Features an ultra-fine 0.0001°C temperature resolution, double-layer 35L/2.3L water tank, precision volume balancing (<0.5g error), imported circulation stirrer, and dedicated Windows software for automated calorific value testing.
  • JCNR-60 Prüfgerät für schwer brennbare Baustoffe wird strikt eingehalten AUS 4102-15/16 (Brandschacht Test) Und GB/T 8625-2026. Features a vertical shaft furnace, constant 20°C air supply unit, 10-minute fixed methane flame exposure with 540°C surface heat load, automated PC flue gas temperature tracking with 200°C auto test stop, and precision gas flow control for construction material B1 fire certification.
  • JCKR Building Material Combustibility Test Apparatus wird strikt eingehalten ISO 11925-2:2026, IN 13501-1 (Euroclass B/C/D/E), GB/T 8626, AUS 4102-1 (B2), Und IN 13238 Standards. Features a 1.5mm stainless steel cabinet, 7-inch industrial touchscreen, motorized burner 45° positioning, high-voltage auto-ignition with 5s/15s/30s timers, and a complete mounting accessory kit for Class B1/B2 fire classification.
  • Der Einzelner brennender Gegenstand (SBI) Testausrüstung (JCDT Series) is a fully automated, high-precision fire reaction test system designed to evaluate heat release, smoke growth, and flammability of building materials. Built strictly to meet IN 13823, IN 13501-1 (Euroclass A2, B, C, D), Und GB/T 20284 Standards.
    • Precision Gas Analysis Rack: Equipped with a paramagnetic O₂ analyzer (±0.1%) and NDIR CO₂ analyzer for exact HRR & FIGRA measurements.
    • Automated PC DAQ Software: One-click test control with real-time automated calculation of THR₆₀₀ₛ, SMOGRA, and TSP₆₀₀ₛ.
    • Double-Insulated J-Duct & Hood: Maintains consistent airflow (0.50–0.65 m³/s) and eliminates thermal loss during combustion.
    • AUS 50055 Optical Smoke System: High-stability white-light attenuation optics for continuous light transmittance assessment.

    ✓ Cost-effective Euroclass testing solution for certification bodies, third-party labs, and building product manufacturers. Contact us for full technical specifications & instant pricing!

  • High-precision EN ISO 1182, ISO 1182:2020, GB/T 5464-2026, GB 8624-2025, IN 13238, BS 476-4, ASTM E136 Non-Combustibility Tester for evaluating building material fire performance at 750°C. Fully compliant with IMO FTP Part 1 and ASTM E2652, featuring automated PID temperature control, multi-point K-type thermocouples, real-time DAQ software, and Euroclass A1/A2 pass/fail analysis.
  • GTL-50-Stahlkonstruktion, feuerhemmende Beschichtung, Mustertestofen strictly meets ISO 834, BS 476 (Parts 20/21), IN 13381-4/8, ASTM E119, UL 263, Und GB 14907-2018 Standards. Features touch screen & wireless PC dual control, diesel spray heating up to 1210°C / 360 min, constant 20±3Pa furnace pressure control, auto thermocouple fault elimination, and automatic curve logging for steel coating fire resistance evaluation.
  • ISO 1167 Hydrostatic Pressure Tester
    Pipe hydrostatic pressure tester engineered for long-term constant-pressure Und instantaneous burst testing of thermoplastic pipes from DN16 to DN1600. The GJ16C pairs a 3-channel modular pressure control unit with a 304 stainless steel constant-temperature water tank and patented Type A radial-seal fixtures — delivering 0.4–16 MPa control, ±0.1% timing accuracy and full ISO 1167/ ISO 9080:2012 / ASTM D1598 / ASTM D1599 compliance. Every channel runs and stores data independently, so a failure on one station never interrupts the others.
  • Hydraulisch & Druckprüfstand für Sanitärventile (DN200 / 6.3 MPa) Entspricht strikt der API 598, ISO 5208, und EN 12266-1 Standards. Verfügt über zwei Anschlussmöglichkeiten für Ventile mit Innengewinde und Flansch bis DN200 (8"), eine energieeinsparung 0.75 kW-Motor, pneumatisch-hydraulische Verstärkerschaltungen, und Multi-Mode-Tests zur Schalenfestigkeit, Flüssigkeitssitzleckage, Niederdruck-Gasdichtheit, und Rücksitzabdichtung.
Nach oben gehen