JRZ10 Bruttoverbrennungswärmetester für Baustoffe wird strikt eingehalten ISO 1716:2018, IN 13501-1 (Euroclass A1/A2), GB/T 14402-2026, ASTM D5865, Und ASTM D240 Standards. Features an ultra-fine 0.0001°C temperature resolution, double-layer 35L/2.3L water tank, precision volume balancing (<0.5g error), imported circulation stirrer, and dedicated Windows software for automated calorific value testing.
-
JCKR Building Material Combustibility Test Apparatus wird strikt eingehalten ISO 11925-2:2026, IN 13501-1 (Euroclass B/C/D/E), GB/T 8626, AUS 4102-1 (B2), Und IN 13238 Standards. Features a 1.5mm stainless steel cabinet, 7-inch industrial touchscreen, motorized burner 45° positioning, high-voltage auto-ignition with 5s/15s/30s timers, and a complete mounting accessory kit for Class B1/B2 fire classification.
-
Vertikales Flammenprüfgerät CS380 mit gebündeltem Kabel wird strikt eingehalten IEC 60332-3-10 / IEC 60332-3-21~25 (Categories A F/R, A, B, C, D), GB/T 18380.31~36, UL 1685, IN 45545-2, Und IN 50399 Standards. Features a 1m×2m×4m mineral-wool-insulated 304 stainless steel chamber, PLC touchscreen control, electric specimen crane, dual propane ribbon burners with Venturi gas mixers, and automated gas shut-off for bundled wire & optical cable fire resistance testing.
-
GTL-50-Stahlkonstruktion, feuerhemmende Beschichtung, Mustertestofen strictly meets ISO 834, BS 476 (Parts 20/21), IN 13381-4/8, ASTM E119, UL 263, Und GB 14907-2018 Standards. Features touch screen & wireless PC dual control, diesel spray heating up to 1210°C / 360 min, constant 20±3Pa furnace pressure control, auto thermocouple fault elimination, and automatic curve logging for steel coating fire resistance evaluation.
-
CYD-Rauchtoxizitätstestausrüstung wird strikt eingehalten GB/T 20285-2006, AUS 53436, BS EN 17084, ISO 19702, Und JIS A 1321 protocols. Features an annular furnace powered by Swedish Kanthal wire, precision stepper motor drive (10±0.1 mm/min), zero-leakage quartz pipeline assembly, and 10-channel Hall-sensor mouse activity tracking for automated material smoke hazard classification testing.
-
NH-016 Cable Fire Resistance Tester ist eine hochpräzise, heavy-duty laboratory system designed to evaluate the circuit integrity, thermal endurance, and electrical survival of power, Daten, and optical cables under severe fire conditions up to 1000°C (with optional water spray & mechanical shock).
Key Features:
- Multi-Standard Compliance: Engineered strictly according to IEC 60331 (Parts 1/2/11/21/23/25), BS 6387:2013, BS 8491, IN 50200, Und GB/T 19216.
- Heavy-Duty Chamber: Integrated 3m × 3m × 3m 304 stainless steel insulated combustion chamber with high-temperature fireproof lining.
- 5-Channel Independent Electrical Load: Precise voltage and current control (0–1000V / 0.1–3A) per channel.
- Precision Flame & Gas Control: Dual propane ribbon burners equipped with Mass Flow Controllers (MFC) for accurate temperature regulation.
- Automated Control: Intuitive PLC touch-screen display for seamless operation, test automation, and real-time data logging.
- Zielanwendungen: Ideal for wire & cable manufacturers, third-party fire testing agencies, rail transit, marine classification societies, and research institutes.
-
NH-XL Vertical Integrated Fire Resistance Test Furnace strictly complies with GB/T 9978, GB 12955-2024, GB 16809-2024, und ISO 834-1 Standards. Features a 3.0m × 3.0m × 1.2m cavity, lightweight high-alumina zirconia fiber suspended lining (up to 1300°C), 8 proportional gas burners, closed-loop pressure control, and automated PC data logging for fire doors, windows, shutters, and partition wall integrity & insulation testing.
-
Der JYMD Building Materials Rauchdichtetester is a professional static smoke generation testing apparatus designed for plastics, Polymere, and synthetic building materials. Strictly engineered according to ASTM D2843 Und GB/T 8627-2007, it provides precise, automated measurement of Maximum Smoke Density (MSD) and Smoke Density Rating (SDR).
-
JCNR-60 Prüfgerät für schwer brennbare Baustoffe wird strikt eingehalten AUS 4102-15/16 (Brandschacht Test) Und GB/T 8625-2026. Features a vertical shaft furnace, constant 20°C air supply unit, 10-minute fixed methane flame exposure with 540°C surface heat load, automated PC flue gas temperature tracking with 200°C auto test stop, and precision gas flow control for construction material B1 fire certification.
-
SPCZ-06 Kunststoffschaum vertikal & Horizontaler Brenntester wird strikt eingehalten ISO 9772 & ASTM D4986 Standards. Features dual horizontal and vertical testing configurations, touchscreen & wireless PC control, 0.1s/1mm high-precision measurement, visual gas pressure monitoring, 9.5mm wing-top Bunsen burner, and automated exhaust cooling for cellular and rigid foam flammability rating.
-
FCZ-50 Textile Vertical Flammability Tester wird strikt eingehalten ASTM D6413, 16 CFR Teil 1615/1616, ISO 6940/6941, BS EN ISO 15025, Und GB/T 5455-2014 für die Prüfung der vertikalen Feuerbeständigkeit von Stoffen. Verfügt über ein MCGS-Farb-Touchscreen-Bedienfeld, zwei vorprogrammierte Testmodi (Zustand A & B), 0.1s Timer-Auflösung, Gasdrucküberwachung in Echtzeit, und ein kompletter Satz Standard-Gegengewichte (54.5g–453,6g) zur Messung der Nachbrennzeit, Nachglühzeit, und beschädigte Länge.
-
JYZS-20 Oxygen Index Tester strictly complies with ISO 4589-2, ASTM D2863, BS 2782-1, NES 715, GB/T 2406, GB/T 5454 Standards. Features automated touchscreen gas regulation, closed-loop concentration correction (±0.1% accuracy), an imported 0–100% oxygen sensor (<5s response), dual specimen holders for rigid/flexible polymers, and a 40±2mm/s airflow combustion column for precise Limiting Oxygen Index (LOI) testing.