BRT AA1800 dedicated flame AAS with double-beam optics, 185–rango de 900 nm, eight-lamp turret and titanium burner head. Full datasheet specifications.

Consulta ahora

DIRECCIÓN DE CORREO ELECTRÓNICO

NOMBRE DE PILA

APELLIDO

WhatsApp

MENSAJE

Product overview

El BRT AA1800 is a dedicated flame atomic absorption spectrophotometer. It is built for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis, using a double-beam optical path, an eight-lamp turret and a titanium burner head.

BRT AAS instrument viewed from front left with open sample compartment and autosampler attached
Front-left three-quarter view of the BRT AAS system with the graphite furnace sampler fitted.

Key features across the series

  • Total-reflection optical system designed for high signal-to-noise performance.
  • Eight-lamp turret with 360° rotation and simultaneous preheating of 1–4 lamps.
  • Windows workstation software with automatic control, QA/QC functions, SD/RSD calculation and calibration-curve correlation checking.
  • Multiple data-processing modes including average, peak height, peak area and statistical analysis.
  • One-click database access for wavelength, ancho de banda espectral, lamp current, negative high voltage and energy-balance settings.

Optical system and photometric performance

ParámetroAA1800AA1900AA2000
Instrument typeFlame systemFlame & GFAA integratedFlame & GFAA integrated
Beam typeDouble-beamDouble-beamDouble-beam
Diffraction grating1800 lines/mm; blaze wavelength 250 Nuevo Méjico1800 lines/mm; blaze wavelength 250 Nuevo Méjico1800 lines/mm; blaze wavelength 250 Nuevo Méjico
Rango de longitud de onda185–900 nm185–900 nm185–900 nm
Ancho de banda espectral0.1, 0.2, 0.4, 0.7, 1.4, 2.0 Nuevo Méjico0.1, 0.2, 0.4, 0.7, 1.4, 2.0 Nuevo Méjico0.1, 0.2, 0.4, 0.7, 1.4, 2.0 Nuevo Méjico
Precisión de longitud de onda±0.15 nm±0.20 nm±0.15 nm
Repetibilidad de longitud de onda≤0.05 nm≤0.10 nm≤0.05 nm
Spectral bandwidth deviation±0.02 nm±0.02 nm±0.02 nm
Lamp stand8 lamps; simultaneous preheating of 1–4 lamps8 lamps; simultaneous preheating of 1–4 lamps8 lamps; simultaneous preheating of 1–4 lamps
Front view of the BRT AAS with both housings, open sample compartment, cyan tubing and autosampler lid
Straight-on front view of the AAS with both atomization units visible.

Rendimiento fotométrico

ParámetroAA1800AA1900AA2000
Reading modesTransmitancia, absorbancia, concentraciónTransmitancia, absorbancia, concentraciónTransmitancia, absorbancia, concentración
rango fotométrico0–125%T; −0.1–3.00 Abs0–125%T; −0.1–3.00 Abs0–125%T; −0.1–3.00 Abs
Baseline stability±0.002 Abs (steady 30 mín.); ±0.004 Abs (dynamic 15 mín.)±0.003 Abs (steady 30 mín.); ±0.005 Abs (dynamic 15 mín.)±0.002 Abs (steady 30 mín.); ±0.004 Abs (dynamic 15 mín.)
Background correctionD₂ lamp ≥40-fold (1 abdominales); self-reversal ≥80-fold (1 abdominales)D₂ lamp ≥40-fold (1 abdominales)D₂ lamp ≥40-fold (1 abdominales); self-reversal ≥80-fold (1 abdominales)

Flame analysis

ParámetroAA1800AA1900AA2000
Characteristic concentration (Cu)≤0.02 μg/mL≤0.035 μg/mL≤0.02 μg/mL
Detection limit (Cu)≤0.004 μg/mL≤0.006 μg/mL≤0.004 μg/mL
Repetibilidad (Cu)≤0.5%≤0.6%≤0.5%
QuemadorTitanium burner headTitanium burner headTitanium burner head
NebulizerHigh-efficiency glass nebulizerHigh-efficiency glass nebulizerHigh-efficiency glass nebulizer
SeguridadFlame gas & auxiliary gas abnormal-pressure protectionFlame gas & auxiliary gas abnormal-pressure protectionFlame gas & auxiliary gas abnormal-pressure protection

Titanium burner and nebulizer

AA1800 uses a titanium burner head with a high-efficiency glass nebulizer. Flame gas and auxiliary gas abnormal-pressure protection is standard.

Data processing

ParámetroAA1800AA1900AA2000
Concentration calculationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolation
Repeated measurements1–30 times; average, SD and RSD of absorbance/concentration1–30 times; average, SD and RSD of absorbance/concentration1–30 times; average, SD and RSD of absorbance/concentration

Accessories and physical data

ParámetroAA1800AA1900AA2000
Standard accessoriesCu lamp ×1; oil-free air compressor; software; USB flash driveCu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL)Cu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL)
Optional accessoriesOxygen-enriched high-temperature flame; hydride generator; audit-trail software; flame autosamplerOxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosamplerOxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler
Power supplyC.A. 220 V, 50/60 HzC.A. 220 V, 50/60 HzC.A. 220 V, 50/60 Hz
External size (W×D×H)830×650×560 mm830×650×560 mm830×650×560 mm
Package size (W×D×H)1010×780×830 mm1010×780×830 mm1010×780×830 mm
Net weight85 kilos120 kilos125 kilos
Gross weight135 kilos183 kilos183 kilos

Service connections and installation

Close-up of BRT AAS rear panel with cooling louvres, brand plate, mains inlet and gas and water connectors
Detail of the rear panel with power inlet and gas/water connectors.

Rear-panel mains inlet, gas and water connectors are grouped for bench installation. The instrument sits on vibration-isolation feet; unpacking and leveling are required before atomizer alignment.

Frequently asked questions

What elements can this AAS determine?

The series is specified for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. Element-specific detection limits are supplied for Cu and Cd in the datasheet; limits for other elements must be confirmed against your application.

What is the wavelength range?

All three models cover 185–900 nm with a 1800 lines/mm grating blazed at 250 Nuevo Méjico.

How many lamps can be fitted?

The turret holds eight lamps and can preheat 1–4 lamps simultaneously.

Does AA1800 include a graphite furnace?

No. AA1800 is a dedicated flame system. For graphite furnace atomization, specify AA1900 or AA2000.

Which background correction is fitted?

AA1800 and AA2000 specify D₂ lamp ≥40-fold (1 abdominales) and self-reversal ≥80-fold (1 abdominales). AA1900 specifies D₂ lamp ≥40-fold (1 abdominales).

What data processing is available?

Standard curve with six linear/non-linear fitting methods, standard addition and interpolation; 1–30 repeated measurements with average, SD and RSD.

What power supply is required?

C.A. 220 V, 50/60 Hz for all three models.

Related models

Compare also: BRT AA1900 BRT AA2000.

See the complete BRT AAS series comparison.