BRT-6100UV UV Vis Spectrophotometer is a 20 kg digital double-beam instrument featuring a 5-inch (320×240) graphic LCD screen, 190–1100 nm spectral range, 1.8 nm bandwidth, et 1200 lines/mm grating. It supports standalone spectrum scanning, cinétique, DNA/protein assays, and multi-wavelength testing with 5–100 mm cuvette flexibility. Includes 8GB USB storage, 2 quartz/4 glass cuvettes, LPT printer output, and GLP-compliant PC software.

UGS: BRT-6100UV, Catégories: ,
Demande maintenant

ADRESSE EMAIL

PRÉNOM

NOM DE FAMILLE

WhatsApp

MESSAGE

Le BRT-6100UV UV Vis Spectrophotometer is a high-precision digital double-beam laboratory instrument featuring a 320×240 graphic dot-matrix LCD screen, un 1200 lines/mm holographic grating, and pre-aligned socket-type deuterium and tungsten halogen light sources. Engineered for advanced pharmaceutical QA/QC, molecular biology, surveillance environnementale, and chemical analysis, it covers the 190 nm to 1100 nm spectral range with a 1.8 nm optical bandwidth, ±0.3 nm wavelength accuracy, and ≤0.1 nm wavelength repeatability for consistent, highly reproducible measurements.

Equipped with dual-beam optical stabilization to continuously eliminate light source intensity fluctuations, this versatile Spectrophotomètre UV Vis provides built-in analytical modes for photometric, quantitative, kinetic, multi-wavelength, and DNA/Protein ratio testing. Featuring a spacious sample chamber accommodating 5 mm à 100 mm cuvettes, onboard data storage with an included 8GB USB drive, parallel printer support, and GLP-compliant PC analysis software, le 20 kg BRT-6100UV simplifies complex laboratory workflows.


UV Vis Spectrophotometer Measurement & Capacités d'analyse

This digital double-beam spectrophotometer enables lab technicians to execute comprehensive testing routines directly from the standalone unit or via connected PC software:

Mode d'analyse Méthodologie & Portée opérationnelle Application de test primaire
Photometer & Multi-Wavelength Direct evaluation of Absorbance, Transmittance (%T), Energy, and Concentration at single or multiple fixed wavelengths across 190–1100 nm Optical density screening, multi-component mixture analysis, vérification des matières premières, and purity checks
Quantitative Analysis Concentration determinations using standard coefficient equation entry ($C = KA + B$) or multi-point standard curves (up to 10 standard samples) Pharmaceutical active ingredient quantification, environmental water pollutant assays (MORUE, nitrate, phosphate), and chemical concentration profiling
Kinetic Reaction Rates Measures sample changes over user-defined time intervals at fixed wavelengths, automatically plotting time-course curves and calculating reaction rates (ΔA/Δt) Enzymatic activity assays, dynamic chemical degradation studies, and reaction rate determination
Spectrum Scanning Scans Absorbance and Transmittance curves across the full 190–1100 nm range, automatically identifying peak absorption maxima Qualitative compound identification, unknown spectrum profiling, and spectral characterization
DNA/Protein Analysis Built-in calculations to directly yield nucleic acid concentrations, protein content, and purity ratios (par ex., A260/A280, A260/A230) Molecular biology, DNA/RNA extraction quality checks, and protein concentration assays

Technological Features of BRT-6100UV UV Vis Spectrophotometer

  • Digital Double-Beam Optical System

    Features a double-beam optical configuration that automatically eliminates errors caused by light source intensity fluctuations, ensuring stable readings and minimal stray light.

  • 5-Inch Graphic Dot-Matrix LCD (320×240)

    Large blue graphic LCD screen displays measurement spectra, regression curves, and kinetic trends directly on screen with switchable bilingual menus (English/Chinese).

  • Spacious Sample Chamber (5 mm à 100 mm Path Lengths)

    Versatile sample compartment accommodates standard cuvettes as well as long-path rectangular cells up to 100 mm for low-concentration liquid samples.

  • Expanded Memory & USB Mass Storage (8GB Drive Included)

    Generous internal memory supports direct storage of curves and datasets, supplemented by a USB port and an included 8GB USB flash drive with custom file naming capabilities.

  • Socket-Type Dual Light Sources & Real-Time Monitoring

    Pre-aligned deuterium and tungsten halogen lamps feature socket-type mountings for quick replacement without optical alignment, backed by real-time lamp life monitoring.

  • GLP-Compliant PC Software & Direct Print Output

    Includes Mapada professional analysis software with GLP self-identification for complete PC control, data export, and direct hard-copy printing via an LPT parallel port.


Technical Specifications of UV Vis Spectrophotometer

Modèle de produit BRT-6100UV Digital Double Beam UV Vis Spectrophotometer
Optical Architecture Double Beam Optical System, 1200 lines/mm Holographic Grating
Wavelength Range & Résolution 190 nm to 1100 nm; Spectral Bandwidth: 1.8 nm; Résolution: 0.1 nm
Wavelength Accuracy & Répétabilité Précision: ±0,3 nm; Répétabilité: ≤0.1 nm
Photometric Range & Précision 0 to 200%T, -0.301 à 3.000 Abs, -9999 à 9999 C; Transmittance Accuracy: ±0.3%T
Light Sources & Afficher Socket-Type Deuterium & Tungsten Lamps; 320 × 240 Graphic LCD Display
Storage & External Ports Internal Storage + 8GB USB Drive; USB PC Port, LPT Parallel Printer Port
Supported Cuvette Path Lengths 5 mm à 100 mm Path Length Cuvettes
Dimensions & Poids de l'instrument 590 × 420 × 260 mm (W × D × H); Poids total: 20 kilos (44.09 kg)

Accessoires de l'emballage standard inclus

  • Unité hôte principale: BRT-6100UV Digital Double Beam UV Vis Spectrophotometer (1 unité).
  • Cuvettes Supplied: 10 mm Standard Quartz Cuvettes (2 pcs for UV range) & 10 mm Standard Glass Cuvettes (4 pcs for Visible range).
  • Data Storage Accessories: 8GB USB Flash Drive for external dataset storage.
  • Logiciel & Cables: Standard-Equipped Mapada Professional PC Analysis Software, USB Interface Cable, Cordon d'alimentation.
  • Documentation: Manuel d'instructions d'utilisation, Quality Certificate, Carte de garantie.

Flux de travail de test & Applications cibles

Flux de travail de test standardisé:

  1. Power on the BRT-6100UV; the system executes self-calibration for wavelength alignment and dark current adjustment.
  2. Select the desired operating mode (Photometric, Quantitative, Kinetics, Spectrum Scan, or DNA/Protein) on the graphic LCD.
  3. Place a reference blank into the reference beam path and execute automatic 0A / 100%T baseline zeroing.
  4. Insert test samples to acquire direct absorbance readings, plot spectrum curves, measure reaction rates, or evaluate DNA purity.
  5. Save datasets to internal storage or the included 8GB USB drive, export to GLP-compliant PC software, or print direct analytical reports via the LPT port.

Applications client cibles:

  • Molecular biology, genomics, and protein research laboratories requiring direct DNA/RNA quantification.
  • Pharmaceutical manufacturing QA/QC, drug testing facilities, and raw material validation centers.
  • Environmental protection agencies evaluating water purity, heavy metals, nitrates, and COD levels.
  • University chemistry research departments, biochemistry institutes, and food safety testing laboratories.

UV Vis Spectrophotometer FAQ

T1: How does the DNA/Protein measurement mode function on the BRT-6100UV?

UN: The built-in DNA/Protein mode measures absorbance at critical wavelengths (such as 260 nm, 280 nm, et 230 nm) to automatically calculate nucleic acid concentrations and purity ratios (A260/A280, A260/A230) without manual calculations.

T2: What is the advantage of socket-type lamp replacement?

UN: Socket-type deuterium and tungsten halogen lamps allow quick, plug-and-play replacement without requiring complex optical alignment, drastically reducing instrument maintenance downtime.

T3: What analytical modes are provided with the included Mapada PC software?

UN: The GLP-compliant Mapada PC software supports full-spectrum scanning, multi-wavelength testing, quantitative curve fitting, time-resolved kinetics, and customized test report generation.

Avis

Il n'y a pas encore d'avis.

Soyez le premier à donner votre avis "BRT-6100UV UV Vis Spectrophotometer”

Votre adresse email ne sera pas publiée. Les champs obligatoires sont marqués *