High-precision EN ISO 1182, OIN 1182:2020, GB/T 5464-2026, FR 8624-2025, DANS 13238, BS 476-4, ASTM E136 Non-Combustibility Tester for evaluating building material fire performance at 750°C. Fully compliant with IMO FTP Part 1 and ASTM E2652, featuring automated PID temperature control, multi-point K-type thermocouples, real-time DAQ software, and Euroclass A1/A2 pass/fail analysis.

SKU: JBR20, Catégories: ,
Demande maintenant

ADRESSE EMAIL

PRÉNOM

NOM DE FAMILLE

WhatsApp

MESSAGE

Le JBR20 Building Material Non-Combustibility Tester is a high-precision, computerized laboratory furnace designed to determine the absolute non-combustibility and thermal response of homogeneous building products and major components of non-homogeneous products under 750 °C exposure. Engineered strictly in accordance with OIN 1182:2020, GB/T 5464-2026, FR 8624-2025, et DANS 13501-1 (Euroclass A1/A2), this apparatus serves as the primary system for non-combustible material certification.

Featuring dual-loop temperature and power control, stage-regulated soft-start heating, automatic flame duration logging, and an optimized dual-thermocouple furnace setup, the JBR20 Non-Combustibility Furnace delivers exceptional accuracy and speed for insulation producers, fire safety inspection agencies, and accredited ISO 17025 test facilities.


Applicable Standards & Fire Classification Systems

This 750 °C vertical tube non-combustibility furnace enables certified testing facilities to conduct global flammability and material rating evaluations:

Standard Code Standard Title & Scope Primary Testing Application
OIN 1182:2020 Reaction to fire tests for products — Non-combustibility test International benchmark procedure utilizing dual furnace thermocouples for critical non-combustibility verification
FR 8624-2025 & GB/T 5464-2026 Classification for burning behavior of building materials & Non-combustibility test method Mandatory Chinese national standardization testing for Class A1 and A2 non-combustible building product ratings
DANS 13501-1 / DANS 13238 Fire classification of construction products — Part 1: Euroclass A1 & A2 classification rules Mandatory CE marking non-combustibility evaluation for European construction material export certification
BS 476-4 & ASTM E136 Fire tests on building materials — Non-combustibility test in a vertical tube furnace at 750 °C British and North American building code compliance testing for structural non-combustible material status
IMO FTP Code Part 1 International Code for Application of Fire Test Procedures — Non-combustibility test Marine Equipment Directive (MED) compliance testing for marine bulkheads, decks, and insulation materials

Key Technological Features of JBR20 Non-Combustibility Apparatus

  • OIN 1182:2020 Dual Thermocouple Configuration: Fully complies with the latest international guidelines, utilizing two furnace-temperature thermocouples along with optional specimen surface and specimen center probes.
  • Advanced Dual-Loop Control Algorithm: Advanced temperature and power dual-loop regulation ensures smooth automatic transitions from constant temperature to constant power without manual intervention.
  • Precision Voltage & Power Compensation: Operates at standard 100 V heating voltage. Built-in power compensation keeps power fluctuations below 1% and empty furnace temperature variance under 2 °C even during mains voltage fluctuations.
  • Soft-Start Heating Protection: Software-managed multi-stage heating curve prevents thermal shock to furnace heating elements, extending furnace core operational life.
  • Automated Flame Logging & Data Analysis: Automatically detects and logs sustained flame duration, eliminating manual timing errors, and allows full raw data export and querying.
  • All-Stainless Steel Body Construction: Heavy-duty, high-temperature-resistant stainless steel enclosure ensures corrosion resistance and reliable continuous testing.

Technical Specifications of JBR20 Non-Combustibility Tester

Governing Standards OIN 1182:2020, GB/T 5464-2026, FR 8624-2025, DANS 13238, BS 476-4, ASTM E136
Furnace Operating Range Ambient temperature to 1000 °C (Standard operational stabilization at 750 °C ± 5 °C)
Heating Voltage & Power 0 to 100 V heating voltage; 0 to 1500 W variable heating power
Furnace Tube Dimensions Height: 150 ± 1 mm; Inner Diameter: 75 ± 1 mm; Wall Thickness: 10 ± 1 mm
Thermocouple Specifications Class 1 accuracy Type K (4 total: 2 furnace wall, 1 specimen center, 1 specimen surface); Wire Ø0.3 mm, Outer Ø1.5 mm
Specimen Dimensions Cylindrical Ø45 mm × 50 mm
Stabilization Warm-Up Time Rapid stabilization within 40 to 60 minutes to reach constant 750 °C operational state
Power Supply & Environment Single-phase AC 220 V ± 5%, 50 Hz; Ambient Temp: 23 ± 5 °C; Humidity: 50 ± 20% RH

Testing Workflow & Non-Combustibility Assessment

Standardized Testing Procedure:

  1. Prepare standardized cylindrical test specimens measuring Ø45 mm × 50 mm in accordance with GB/T 40238 / DANS 13238 conditioning procedures.
  2. Power on the JBR20 apparatus and initiate the software-controlled soft-start ramp to stabilize the furnace furnace temperature at 750 °C (stabilization within 40–50 min).
  3. Mount the specimen inside the specimen holder and position thermocouples at the specimen center and surface if required.
  4. Lower the specimen holder into the center of the vertical tube furnace using the height-positioning stop block.
  5. The computerized software continuously records temperature curves (furnace, specimen center, specimen surface) and monitors for any flaming activity.
  6. Record the maximum temperature rise ($\Delta T$), mass loss percentage ($\Delta m$), and sustained flaming time ($t_f$) upon test completion.
Test Parameter

Ignitability

Standard

ASTM E2652, BS 476-4, DANS 13501-1, EN ISO 1182, GB/T 5464, IMO FTP Code Part 1