• JRZ10 Gross Heat of Combustion Tester for Building Materials strictly complies with ISO 1716:2018, IN 13501-1 (Euroclass A1/A2), GB/T 14402-2026, ASTM D5865, E ASTM D240 standard. Features an ultra-fine 0.0001°C temperature resolution, double-layer 35L/2.3L water tank, precision volume balancing (<0.5g error), imported circulation stirrer, and dedicated Windows software for automated calorific value testing.
  • JCKR Building Material Combustibility Test Apparatus strictly complies with ISO 11925-2:2026, IN 13501-1 (Euroclass B/C/D/E), GB/T 8626, DA 4102-1 (B2), E IN 13238 standard. Features a 1.5mm stainless steel cabinet, 7-inch industrial touchscreen, motorized burner 45° positioning, high-voltage auto-ignition with 5s/15s/30s timers, and a complete mounting accessory kit for Class B1/B2 fire classification.
  • Attrezzatura per test di fiamma verticale con cavo in bundle CS380 strictly complies with IEC 60332-3-10 / IEC 60332-3-21~25 (Categories A F/R, UN, B, C, D), GB/T 18380.31~36, UL 1685, IN 45545-2, E IN 50399 standard. Features a 1m×2m×4m mineral-wool-insulated 304 stainless steel chamber, PLC touchscreen control, electric specimen crane, dual propane ribbon burners with Venturi gas mixers, and automated gas shut-off for bundled wire & optical cable fire resistance testing.
  • GTL-50 Steel Structure Fire Retardant Coating Sample Test Furnace strictly meets ISO 834, BS 476 (Parti 20/21), IN 13381-4/8, ASTM E119, UL 263, E GB 14907-2018 standard. Features touch screen & wireless PC dual control, diesel spray heating up to 1210°C / 360 min, constant 20±3Pa furnace pressure control, auto thermocouple fault elimination, and automatic curve logging for steel coating fire resistance evaluation.
  • Attrezzatura per test di tossicità del fumo CYD strictly complies with GB/T 20285-2006, DA 53436, BS EN 17084, ISO 19702, E JIS A 1321 protocols. Features an annular furnace powered by Swedish Kanthal wire, precision stepper motor drive (10±0.1 mm/min), zero-leakage quartz pipeline assembly, and 10-channel Hall-sensor mouse activity tracking for automated material smoke hazard classification testing.
  • NH-016 Cable Fire Resistance Tester è un'alta precisione, heavy-duty laboratory system designed to evaluate the circuit integrity, thermal endurance, and electrical survival of power, dati, and optical cables under severe fire conditions up to 1000°C (with optional water spray & mechanical shock).

    Key Features:

    • Multi-Standard Compliance: Engineered strictly according to IEC 60331 (Parti 1/2/11/21/23/25), BS 6387:2013, BS 8491, IN 50200, E GB/T 19216.
    • Heavy-Duty Chamber: Integrated 3m × 3m × 3m 304 stainless steel insulated combustion chamber with high-temperature fireproof lining.
    • 5-Channel Independent Electrical Load: Precise voltage and current control (0–1000V / 0.1–3A) per channel.
    • Precision Flame & Gas Control: Dual propane ribbon burners equipped with Mass Flow Controllers (MFC) for accurate temperature regulation.
    • Automated Control: Intuitive PLC touch-screen display for seamless operation, test automation, and real-time data logging.
    • Applicazioni di destinazione: Ideal for wire & cable manufacturers, third-party fire testing agencies, rail transit, marine classification societies, and research institutes.
  • NH-XL Vertical Integrated Fire Resistance Test Furnace strictly complies with GB/T 9978, GB 12955-2024, GB 16809-2024, and ISO 834-1 standard. Features a 3.0m × 3.0m × 1.2m cavity, lightweight high-alumina zirconia fiber suspended lining (up to 1300°C), 8 proportional gas burners, closed-loop pressure control, and automated PC data logging for fire doors, windows, shutters, and partition wall integrity & insulation testing.
  • IL JYMD Building Materials Smoke Density Tester is a professional static smoke generation testing apparatus designed for plastics, polymers, and synthetic building materials. Strictly engineered according to ASTM D2843 E GB/T 8627-2007, it provides precise, automated measurement of Maximum Smoke Density (MSD) and Smoke Density Rating (SDR).
  • JCNR-60 Building Material Hard-Combustibility Tester strictly complies with DA 4102-15/16 (Brandschacht Test) E GB/T 8625-2026. Features a vertical shaft furnace, constant 20°C air supply unit, 10-minute fixed methane flame exposure with 540°C surface heat load, automated PC flue gas temperature tracking with 200°C auto test stop, and precision gas flow control for construction material B1 fire certification.
  • SPCZ-06 Verticale in schiuma plastica & Tester di combustione orizzontale strictly complies with ISO 9772 & ASTM D4986 standard. Features dual horizontal and vertical testing configurations, touchscreen & wireless PC control, 0.1s/1mm high-precision measurement, visual gas pressure monitoring, 9.5mm wing-top Bunsen burner, and automated exhaust cooling for cellular and rigid foam flammability rating.
  • FCZ-50 Tester verticale di infiammabilità dei tessuti strictly complies with ASTM D6413, 16 CFR Part 1615/1616, ISO 6940/6941, BS EN ISO 15025, E GB/T 5455-2014 for fabric vertical fire resistance testing. Features an MCGS color touchscreen control panel, dual pre-programmed test modes (Condition A & B), 0.1s timer resolution, real-time gas pressure monitoring, and a complete set of standard counterweights (54.5g–453.6g) for measuring afterflame time, afterglow time, and damaged length.
  • JYZS-20 Oxygen Index Tester è rigorosamente conforme alla norma ISO 4589-2, ASTM D2863, BS 2782-1, NES 715, GB/T 2406, GB/T 5454 standard. Features automated touchscreen gas regulation, closed-loop concentration correction (±0.1% accuracy), an imported 0–100% oxygen sensor (<5s response), dual specimen holders for rigid/flexible polymers, and a 40±2mm/s airflow combustion column for precise Limiting Oxygen Index (LOI) test.
  • ZBY Combustion Tester strictly engineered to ASTM D777, GB/T 14656-2009 for flame-retardant paper and paperboard flammability testing (thickness ≤1.6mm). Features an MCU automated control module, ±0.01s precision timing, 0°–45° multi-angle adjustable Bunsen burner, 15–175mm flame height control, and an enclosed observation cabinet for measuring afterflame and afterglow duration.
  • PDCL-01 Tester del flusso di calore radiante strictly designed for ISO 9239-1, ASTM E648, EN ISO 9239-1, NFPA 253, GB/T 11785-2005 flooring fire reaction testing. Features a custom 304 stainless steel radiant burner, 0–15 kW/m² heat flux meter, ±0.1 m/s anemometer for 2.5 m/s steady airflow, split stainless steel cabinet, and multi-gas compatibility (Methane/Propane/LPG) to accurately determine critical radiant flux in carpets, wood, PVC, and composite floorings.
  • Apparecchio per prove su legname ignifugo FHDM strictly designed for GA/T 42.1 (Referencing ASTM E160 & GB/T 8625) wood crib fire resistance testing. Features automatic motorized burner positioning, precise 310°C temperature control, digital timing (±0.1s accuracy), and dual NG/LPG fuel compatibility for evaluating flaming duration and mass loss rate in fire-treated lumber (>20mm thickness).
  • High-precision EN ISO 1182, ISO 1182:2020, GB/T 5464-2026, GB 8624-2025, IN 13238, BS 476-4, ASTM E136 Non-Combustibility Tester for evaluating building material fire performance at 750°C. Fully compliant with IMO FTP Part 1 and ASTM E2652, featuring automated PID temperature control, multi-point K-type thermocouples, real-time DAQ software, and Euroclass A1/A2 pass/fail analysis.
  • IL Singolo oggetto in fiamme (SBI) Attrezzatura di prova (JCDT Series) is a fully automated, high-precision fire reaction test system designed to evaluate heat release, smoke growth, and flammability of building materials. Built strictly to meet IN 13823, IN 13501-1 (Euroclass A2, B, C, D), E GB/T 20284 standard.
    • Precision Gas Analysis Rack: Equipped with a paramagnetic O₂ analyzer (±0.1%) and NDIR CO₂ analyzer for exact HRR & FIGRA measurements.
    • Automated PC DAQ Software: One-click test control with real-time automated calculation of THR₆₀₀ₛ, SMOGRA, and TSP₆₀₀ₛ.
    • Double-Insulated J-Duct & Hood: Maintains consistent airflow (0.50–0.65 m³/s) and eliminates thermal loss during combustion.
    • DA 50055 Optical Smoke System: High-stability white-light attenuation optics for continuous light transmittance assessment.

    ✓ Cost-effective Euroclass testing solution for certification bodies, third-party labs, and building product manufacturers. Contact us for full technical specifications & instant pricing!