IL JYMD Building Materials Smoke Density Tester is a professional static smoke generation testing apparatus designed for plastics, polymers, and synthetic building materials. Strictly engineered according to ASTM D2843 E GB/T 8627-2007, it provides precise, automated measurement of Maximum Smoke Density (MSD) and Smoke Density Rating (SDR).
-
NH-XL Vertical Integrated Fire Resistance Test Furnace strictly complies with GB/T 9978, GB 12955-2024, GB 16809-2024, and ISO 834-1 standard. Features a 3.0m × 3.0m × 1.2m cavity, lightweight high-alumina zirconia fiber suspended lining (up to 1300°C), 8 proportional gas burners, closed-loop pressure control, and automated PC data logging for fire doors, windows, shutters, and partition wall integrity & insulation testing.
-
NH-016 Cable Fire Resistance Tester è un'alta precisione, heavy-duty laboratory system designed to evaluate the circuit integrity, thermal endurance, and electrical survival of power, dati, and optical cables under severe fire conditions up to 1000°C (with optional water spray & mechanical shock).
Key Features:
- Multi-Standard Compliance: Engineered strictly according to IEC 60331 (Parti 1/2/11/21/23/25), BS 6387:2013, BS 8491, IN 50200, E GB/T 19216.
- Heavy-Duty Chamber: Integrated 3m × 3m × 3m 304 stainless steel insulated combustion chamber with high-temperature fireproof lining.
- 5-Channel Independent Electrical Load: Precise voltage and current control (0–1000V / 0.1–3A) per channel.
- Precision Flame & Gas Control: Dual propane ribbon burners equipped with Mass Flow Controllers (MFC) for accurate temperature regulation.
- Automated Control: Intuitive PLC touch-screen display for seamless operation, test automation, and real-time data logging.
- Applicazioni di destinazione: Ideal for wire & cable manufacturers, third-party fire testing agencies, rail transit, marine classification societies, and research institutes.
-
Attrezzatura per test di tossicità del fumo CYD strictly complies with GB/T 20285-2006, DA 53436, BS EN 17084, ISO 19702, E JIS A 1321 protocols. Features an annular furnace powered by Swedish Kanthal wire, precision stepper motor drive (10±0.1 mm/min), zero-leakage quartz pipeline assembly, and 10-channel Hall-sensor mouse activity tracking for automated material smoke hazard classification testing.
-
GTL-50 Steel Structure Fire Retardant Coating Sample Test Furnace strictly meets ISO 834, BS 476 (Parti 20/21), IN 13381-4/8, ASTM E119, UL 263, E GB 14907-2018 standard. Features touch screen & wireless PC dual control, diesel spray heating up to 1210°C / 360 min, constant 20±3Pa furnace pressure control, auto thermocouple fault elimination, and automatic curve logging for steel coating fire resistance evaluation.
-
Attrezzatura per test di fiamma verticale con cavo in bundle CS380 strictly complies with IEC 60332-3-10 / IEC 60332-3-21~25 (Categories A F/R, UN, B, C, D), GB/T 18380.31~36, UL 1685, IN 45545-2, E IN 50399 standard. Features a 1m×2m×4m mineral-wool-insulated 304 stainless steel chamber, PLC touchscreen control, electric specimen crane, dual propane ribbon burners with Venturi gas mixers, and automated gas shut-off for bundled wire & optical cable fire resistance testing.
-
JCKR Building Material Combustibility Test Apparatus strictly complies with ISO 11925-2:2026, IN 13501-1 (Euroclass B/C/D/E), GB/T 8626, DA 4102-1 (B2), E IN 13238 standard. Features a 1.5mm stainless steel cabinet, 7-inch industrial touchscreen, motorized burner 45° positioning, high-voltage auto-ignition with 5s/15s/30s timers, and a complete mounting accessory kit for Class B1/B2 fire classification.
-
JRZ10 Gross Heat of Combustion Tester for Building Materials strictly complies with ISO 1716:2018, IN 13501-1 (Euroclass A1/A2), GB/T 14402-2026, ASTM D5865, E ASTM D240 standard. Features an ultra-fine 0.0001°C temperature resolution, double-layer 35L/2.3L water tank, precision volume balancing (<0.5g error), imported circulation stirrer, and dedicated Windows software for automated calorific value testing.
-
JYZS-10 Oxygen Index Tester meets ISO 4589-1/2, GB/T 2406.2, ASTM D2863, BS 2782-1 (Method 141), JIS K 7201-2, E NES 715 standard. Features ±0.1% high-precision digital oxygen analyzer, <5s sensor response, dual gas pressure & flow regulation, 75mm clear glass chimney with 40±2 mm/s constant airflow, and compact 50W desktop design for plastic, cable, foam, and textile LOI flame retardancy testing.
-
ZXLR Cone Calorimeter (Building Material Heat Release Rate Fire Test Machine) è rigorosamente conforme alla norma ISO 5660-1, GB/T 16172-2026, and ASTM E1354 standards. Features a 5000W radiant cone heater (0–100 kW/m²), 0.1g thermally protected weighing system, automated program shield, and integrated gas analysis for HRR, mass loss, smoke, and CO/CO₂ toxic gas evaluation.
-
IL NH-XW Horizontal Fire Resistance Test Furnace is a full-scale industrial testing solution engineered for precast floor slabs, steel beams, concrete decks, and intumescent coatings. Built with a spacious 4.2m × 3.0m × 1.5m combustion chamber, it fully complies with global structural fire safety standards including ISO 834, IN 1363/1365, BS 476, ASTM E119 / UL 263, and GB/T 9978.
- Multi-Standard Compliance: Built-in dynamic temperature-curve tracking for ISO, IN, BS, ASTM/UL, and GB standards.
- Precision Pressure Control: Closed-loop micro-positive furnace pressure control within ±2 Pa accuracy.
- Rapid Thermal Response: 8 proportional LPG burners deliver up to 1300°C maximum working temperature with efficient < 0.5h cool-down.
- Operator Safety First: Equipped with 400°C smoke filtration, high-voltage auto-ignition, and automatic emergency gas cut-off interlocks (>100 Pa).
✓ Trusted by 3rd-party testing institutes, structural coating manufacturers, and research centers worldwide. Request an instant quotation or technical proposal today!
-
SPCZ-05 Horizontal & Vertical Combustion Tester strictly complies with UL 94, GB/T 2408-2021, and IEC 60950-1 standard. Features a PLC touchscreen controller, 50W Bunsen burner with auto-retraction, motorized 4-way sample positioning, automatic gas cut-off, and internal data storage for plastic, gomma, and electronics flammability testing.