Espectrofotômetro UV Vis BRT-1200UV is a benchtop single-beam instrument featuring a 200–1000 nm spectral range, 4 largura de banda nm, 1200 linhas/mm grade holográfica, and ≤0.5 nm wavelength repeatability. Equipped with dual tungsten/deuterium lamps, an LCD display, 9-sample curve fitting, 200-dataset memory, USB PC connectivity, and LPT printer output, it provides precise photometric and quantitative chemical testing.

SKU: BRT-1200UV, Categorias: ,
Consulte agora

ENDEREÇO ​​DE EMAIL

PRIMEIRO NOME

SOBRENOME

whatsapp

MENSAGEM

O Espectrofotômetro UV Vis BRT-1200UV is a high-precision benchtop analytical instrument engineered for multi-mode quantitative chemical analysis, optical absorbance screening, and quality control. Projetado para estações de monitoramento ambiental, pharmaceutical QA/QC laboratories, biochemical research facilities, e departamentos de química universitários, it delivers stable spectral performance across the 200 nm para 1000 nm optical spectrum with a 4 nm spectral bandwidth, ±2 nm wavelength accuracy, and ≤0.5 nm wavelength repeatability.

Built with a high-performance single-beam optical system featuring a 1200 linhas/mm grade holográfica, a high-sensitivity photocell detector, and independently managed tungsten halogen and imported deuterium lamps, este versátil Espectrofotômetro UV-Vis guarantees superior photometric accuracy (±0,3%T) and reliable quantitative linearity. Equipped with an LCD display, onboard memory for 200 datasets and 9-point linear regression curves, USB connection for PC software, and a parallel printer interface, the BRT-1200UV optimizes routine laboratory testing workflows.


Medição por Espectrofotômetro UV Vis & Capacidades de análise

This benchtop single-beam spectrophotometer enables laboratory operators to conduct certified photometric, quantitativo, and kinetic testing routines across liquid and solution samples:

Modo de análise Metodologia & Escopo Operacional Aplicação de teste primário
Photometric Measurement Direct evaluation of Transmittance (%T) and Absorbance (Abdominais) at user-specified fixed wavelengths Routine sample clarity verification, optical density checks, and basic QA transmittance testing
Multi-Point Quantitative Curve Fitting Quantitative concentration profiling using single-point factor method or multi-point calibration fitting up to 9 standard samples with automatic regression calculations Chemical concentration profiling, pharmaceutical active ingredient quantification, and environmental water pollutant assays
Cinética acionada por PC & Análise Espectral Time-course enzyme kinetics, testes de múltiplos comprimentos de onda, and full-spectrum scanning via optional professional PC software interface Enzyme reaction kinetics, thermal degradation monitoring, and complex multi-component sample evaluation

Technological Features of BRT-1200UV UV Vis Spectrophotometer

  • Single-Beam Optics with 1200 L/mm Holographic GratingFeatures an advanced optical path with a 1200 lines/mm holographic grating and silicon photocell detector to deliver sharp optical resolution and high signal purity.
  • High Repeatability (≤0.5 nm) & 0.1 nm Resolution DisplayDelivers tight wavelength repeatability (≤0.5 nm) with a 0.1 nm resolution digital readout for consistent baseline stability across repeated measurements.
  • Automated Zeroing & Lamp SwitchingIncorporate automatic wavelength positioning, automatic 0A and 100%T calibration, and independent microcomputer control for tungsten and deuterium lamp management.
  • Multi-Point Curve Fitting & Onboard MemoryStores up to 200 datasets and regression standard curves generated from up to 9 standard samples directly on the unit without requiring active PC connection.
  • Spacious Sample Chamber (5 mm para 100 mm Pathlength)Accommodates cell holders for cuvettes ranging from 5 mm up to 100 mm pathlengths, facilitating both high-concentration and dilute sample analysis.
  • Dual Communications Interface (USB & LPT)Equipped with a USB port for bidirectional PC software data management and a parallel port (LPT) for direct printing to dedicated laboratory printers.

Especificações Técnicas do Espectrofotômetro UV Vis

Modelo de produto BRT-1200UV Benchtop UV Vis Spectrophotometer
Sistema Óptico & Grating Single Beam, 1200 linhas/mm grade holográfica
Wavelength Spectrum & Largura de banda 200 nm para 1000 nm; Spectral Bandwidth: 4 nm; Resolução de comprimento de onda: 0.1 nm
Precisão do comprimento de onda & Repetibilidade Precisão: ±2 nm; Repetibilidade: ≤0.5 nm
Faixa fotométrica & Precisão 0 para 200%T, -0.301 para 3.000 Abdominais, -9999 para 9999 C; Precisão de transmitância: ±0,3%T
Fontes de luz & Detector Tungsten Halogen Lamp & Imported Deuterium Lamp; High-Sensitivity Silicon Photocell
Data Ports & Storage USB Interface (PC Software Compatible), LPT Parallel Printer Port; 200 Datasets/Curves Memory
Dimensões & Weight Instrument: 490 × 370 × 180 milímetros (W × D × H); Peso total: 14 kg (33.07 Libra)

Acessórios de pacote padrão incluídos

  • Unidade Anfitriã Principal: BRT-1200UV Benchtop UV Vis Spectrophotometer (1 unidade).
  • Cubetas de quartzo: 10 mm Standard Quartz Cuvettes (2 pcs for Ultraviolet spectrum testing).
  • Tigelas de vidro: 10 mm Standard Glass Cuvettes (4 pcs for Visible spectrum testing).
  • Suporte de célula de amostra: Standard Multi-Position Cell Holder.
  • Poder & Data Cabling: AC Power Cable, USB Interface Connection Cable.
  • Documentação & Programas: User Operation Manual, Certificate of Quality, Cartão de garantia.

Teste de fluxo de trabalho & Aplicativos alvo

Fluxo de trabalho de teste padronizado:

  1. Power on the BRT-1200UV; allow the microcomputer system to execute self-testing, light source switching, and baseline initialization.
  2. Select Photometric or Quantitative mode from the LCD menu interface.
  3. Load a blank reference solution in the cuvette chamber and initiate automatic 0A / 100%T zeroing.
  4. Introduce standard samples (até 9 points) to build a multi-point quantitative calibration curve, or place test samples for immediate concentration readout.
  5. Save measurement data (até 200 datasets) to internal memory, stream via USB to PC software, or output directly to a printer via the LPT parallel port.

Aplicativos de clientes-alvo:

  • Environmental testing laboratories (COD, metais pesados, nitrate, and phosphate concentration assays).
  • Pharmaceutical processing facilities, ingrediente farmacêutico ativo (API) labs, and life science centers.
  • Petrochemical quality control bays, chemical plants, and agriculture/fertilizer testing labs.
  • University teaching laboratories, academic research centers, and food & beverage QA labs.

Perguntas frequentes sobre espectrofotômetro UV Vis

1º trimestre: What is the main difference in performance between wavelength repeatability and accuracy on the BRT-1200UV?

UM: Precisão do comprimento de onda (±2 nm) measures how closely the selected wavelength matches the true physical value. Repetibilidade de comprimento de onda (≤0.5 nm) indicates how consistently the instrument returns to the exact same wavelength during repeated tests, ensuring high measurement precision.

2º trimestre: How does multi-point standard curve fitting work on this model?

UM: The BRT-1200UV allows users to analyze up to 9 standard sample concentrations directly on the instrument to establish a linear regression equation, display the curve, and automatically calculate unknown sample concentrations.

3º trimestre: Can I run full spectral scanning or kinetics on the BRT-1200UV?

UM: Sim. While standalone operation handles photometric and quantitative tests, connecting the instrument to a PC via USB with the optional analysis software enables kinetic tracking and full spectral scanning capabilities.

Avaliações

Ainda não há comentários.

Seja o primeiro a avaliar “Espectrofotômetro UV Vis BRT-1200UV”

O seu endereço de email não será publicado. Campos obrigatórios marcados com *