BRT-890 FTIR Spectrometer features a DSP-driven non-orthogonal Michelson interferometer, US-imported KBr/Ge optics, moisture-protected DLATGS detector, and long-life IR source across a 7800–350 cm⁻¹ range with <0.85 cm⁻¹ resolution, an ultra-high 45,000:1 SNR, and <0.05% transmission accuracy. Equipped with an intelligent humidity alarm, dynamic diagnostic monitoring, and tool-free accessory mounting, it delivers accurate solid, liquid, and gas testing for pharmaceutical research, petrochemical QA, and material science.
The BRT-890 FTIR Spectrometer is an advanced, high-precision Fourier transform infrared analytical instrument featuring integrated Digital Signal Processing (DSP), an auto-aligning non-orthogonal Michelson interferometer, and a dynamic internal humidity alarm system. Engineered for high-end research laboratories, pharmaceutical QA/QC facilities, petrochemical processing, and advanced material characterization, it delivers certified molecular spectroscopy across the 7800 cm⁻¹ to 350 cm⁻¹ wavenumber range with an optical resolution better than 0.85 cm⁻¹.
Featuring an extraordinary signal-to-noise ratio (SNR > 45,000:1) and a transmission accuracy better than 0.05%, this research-grade FTIR Spectrometer utilizes an imported US-made KBr/Ge beamsplitter, a long-life air-cooled IR source, and a high-sensitivity moisture-protected DLATGS detector. Built on an integrated cast-aluminum optical bench with tool-free modular accessory positioning, the 19 kg BRT-890 combines industrial-grade structural rigidity with intelligent automated spectral acquisition.
FTIR Spectrometer Measurement & Analysis Capabilities
This high-SNR Fourier transform infrared analyzer empowers research scientists and laboratory analysts to perform standardized qualitative structural analysis and quantitative concentration profiling across solid, liquid, and gaseous sample matrices:
| Analysis Mode | Methodology & Operational Scope | Primary Testing Application |
|---|---|---|
| Attenuated Total Reflectance (ATR) | Direct non-destructive surface testing of solids, powders, liquids, and pastes without sample prep using quick-release diamond or ZnSe ATR crystal modules | Advanced polymer identification, active pharmaceutical ingredient (API) mapping, and film characterization |
| High-Precision Transmission Spectroscopy | Direct transmission analysis utilizing precision KBr pellets, liquid transmission cells, and short/long-path gas sampling chambers | Low-concentration pollutant trace analysis, volatile gas monitoring, and chemical solution checks |
| DSP-Driven Automated Spectral Search | Real-time spectrum acquisition and automated matching against extensive built-in spectral libraries with DSP-enhanced signal filtering | Unknown compound identification, failure analysis of contaminants, and QA pass/fail verification |
Technological Features of BRT-890 FTIR Spectrometer
- DSP Auto Interferometer & Non-Orthogonal OpticsFeatures a permanently aligned, non-orthogonal Michelson interferometer driven by high-speed Digital Signal Processing (DSP) and housed within a cast-aluminum bench to eliminate mechanical drift and environmental vibration.
- Ultra-High Signal-to-Noise Ratio (45,000:1) & 0.85 cm⁻¹ ResolutionDelivers crisp, low-noise spectral baselines with a wavelength resolution better than 0.85 cm⁻¹ and transmission accuracy better than 0.05%, making trace component detection simple.
- Intelligent Humidity Alarm System & Optics ProtectionIncorporates dynamic internal moisture monitoring with a visual warning alarm, a high-capacity desiccant chamber, and moisture-proof optical coatings to preserve delicate KBr optics.
- Tool-Free Plug-and-Play Accessory MountingSupports rapid interchange between ATR crystal units, specular reflection units, and gas sampling cells with precise positioning pins, eliminating optical recalibration during routine workflows.
- Long-Life Air-Cooled IR Light Source (Made in USA)Includes a stable ceramic infrared light source imported from the USA, ensuring steady thermal emission, low drift, and minimal maintenance costs over long operational lifespans.
- Ergonomic Push-Pull Sample ChamberDesigned with a spacious sample compartment (520 × 430 × 250 mm footprint) that minimizes atmospheric air disturbance during sample loading for rapid, repeatable scanning cycles.
Technical Specifications of FTIR Spectrometer
| Product Model | BRT-890 High-Performance FTIR Spectrometer |
| Wavenumber / Spectral Range | 7800 cm⁻¹ to 350 cm⁻¹ |
| Spectral Resolution & Repeatability | Resolution: Better than 0.85 cm⁻¹; Wavelength Repeatability: Better than 0.5 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) & Accuracy | 45,000:1 (Peak-to-Peak, 4 cm⁻¹, 1 min scan); Transmission Accuracy: Better than 0.05% |
| Interferometer & Beamsplitter | DSP-Driven Non-Orthogonal Michelson Interferometer; KBr coated with Ge (Made in USA) |
| Detector & Light Source | High-resolution DLATGS with moisture-proof coating; Long-life air-cooled IR source (Made in USA) |
| Electronics & Communication | High-Speed USB 2.0 (USB 3.0 compatible); Real-time diagnostic monitoring |
| Dimensions & Instrument Weight | 520 mm × 430 mm × 250 mm (L × W × H); Total Weight: 19 kg (41.89 lb) |
Standard Package Accessories Included
- Main Host Unit: BRT-890 High-Performance FTIR Spectrometer Unit (1 unit).
- Core Optics Suite: Pre-installed US-imported KBr/Ge Beamsplitter & DLATGS Detector with Moisture-Proof Coating.
- Sampling Module: Standard Transmission Sample Holder (Modular ATR and gas accessories optional).
- Power & Interface Connectivity: AC Power Adapter, USB Communication Cable.
- Maintenance & Calibration Kit: High-capacity desiccant replacement pack, protective dust cover, and system validation sample.
- Software & Documentation: FTIR Spectral Analysis Software Suite, Comprehensive Spectral Library, Operating Manual, Certificate of Conformity, Warranty Card.
Testing Workflow & Target Applications
Standardized Testing Workflow:
- Power on the BRT-890 and open the analysis software; inspect the dynamic internal humidity status on the control panel.
- Mount the chosen sampling accessory (e.g., Diamond ATR crystal or Transmission cell) into the sample chamber.
- Collect a background spectrum to eliminate ambient atmospheric background interference (CO₂ and H₂O vapor).
- Place the sample on the optical interface and initiate a single-click spectral acquisition cycle.
- Run automated library matching to confirm substance identity or perform peak area integration for quantitative calibration reports.
Target Customer Applications:
- Pharmaceutical research institutes, biomedical manufacturing QA/QC labs, and API formulation testing centers.
- Petrochemical processing plants, organic synthesis research labs, and advanced polymer characterization facilities.
- Food safety inspection agencies and environmental monitoring centers analyzing trace gas/water pollutants.
- University chemistry departments, research institutes, and industrial failure analysis laboratories.
FTIR Spectrometer FAQ
Q1: What advantage does the 45,000:1 Signal-to-Noise Ratio (SNR) provide during testing?
A: A higher SNR of 45,000:1 produces extremely smooth spectral baselines with minimal background noise. This allows for clear detection of weak absorption bands, trace component concentrations, and subtle material impurities that lower-SNR instruments might miss.
Q2: How does the Digital Signal Processing (DSP) system improve interferometer performance?
A: The integrated DSP system continuously monitors and controls mirror movement within the non-orthogonal Michelson interferometer, maintaining precise optical alignment and rapid data processing for ultra-repeatable measurements.
Q3: How does the internal humidity alarm prevent instrument damage?
A: Internal KBr beamsplitters absorb moisture over time. The BRT-890’s humidity alarm system continuously tracks relative humidity inside the optical housing and alerts the operator when the desiccant needs changing, extending optic lifespan.









Reviews
There are no reviews yet.