BRT-890 FTIR Spectrometer features a DSP-driven non-orthogonal Michelson interferometer, US-imported KBr/Ge optics, moisture-protected DLATGS detector, and long-life IR source across a 7800–350 cm⁻¹ range with <0.85 cm⁻¹ resolution, an ultra-high 45,000:1 SNR, and <0.05% transmission accuracy. Equipped with an intelligent humidity alarm, dynamic diagnostic monitoring, and tool-free accessory mounting, it delivers accurate solid, liquid, and gas testing for pharmaceutical research, petrochemical QA, and material science.

Inquiry Now

EMAIL ADDRESS

FIRST NAME

LAST NAME

whatsapp

MESSAGE

The BRT-890 FTIR Spectrometer is an advanced, high-precision Fourier transform infrared analytical instrument featuring integrated Digital Signal Processing (DSP), an auto-aligning non-orthogonal Michelson interferometer, and a dynamic internal humidity alarm system. Engineered for high-end research laboratories, pharmaceutical QA/QC facilities, petrochemical processing, and advanced material characterization, it delivers certified molecular spectroscopy across the 7800 cm⁻¹ to 350 cm⁻¹ wavenumber range with an optical resolution better than 0.85 cm⁻¹.

Featuring an extraordinary signal-to-noise ratio (SNR > 45,000:1) and a transmission accuracy better than 0.05%, this research-grade FTIR Spectrometer utilizes an imported US-made KBr/Ge beamsplitter, a long-life air-cooled IR source, and a high-sensitivity moisture-protected DLATGS detector. Built on an integrated cast-aluminum optical bench with tool-free modular accessory positioning, the 19 kg BRT-890 combines industrial-grade structural rigidity with intelligent automated spectral acquisition.


FTIR Spectrometer Measurement & Analysis Capabilities

This high-SNR Fourier transform infrared analyzer empowers research scientists and laboratory analysts to perform standardized qualitative structural analysis and quantitative concentration profiling across solid, liquid, and gaseous sample matrices:

Analysis Mode Methodology & Operational Scope Primary Testing Application
Attenuated Total Reflectance (ATR) Direct non-destructive surface testing of solids, powders, liquids, and pastes without sample prep using quick-release diamond or ZnSe ATR crystal modules Advanced polymer identification, active pharmaceutical ingredient (API) mapping, and film characterization
High-Precision Transmission Spectroscopy Direct transmission analysis utilizing precision KBr pellets, liquid transmission cells, and short/long-path gas sampling chambers Low-concentration pollutant trace analysis, volatile gas monitoring, and chemical solution checks
DSP-Driven Automated Spectral Search Real-time spectrum acquisition and automated matching against extensive built-in spectral libraries with DSP-enhanced signal filtering Unknown compound identification, failure analysis of contaminants, and QA pass/fail verification

Technological Features of BRT-890 FTIR Spectrometer

  • DSP Auto Interferometer & Non-Orthogonal OpticsFeatures a permanently aligned, non-orthogonal Michelson interferometer driven by high-speed Digital Signal Processing (DSP) and housed within a cast-aluminum bench to eliminate mechanical drift and environmental vibration.
  • Ultra-High Signal-to-Noise Ratio (45,000:1) & 0.85 cm⁻¹ ResolutionDelivers crisp, low-noise spectral baselines with a wavelength resolution better than 0.85 cm⁻¹ and transmission accuracy better than 0.05%, making trace component detection simple.
  • Intelligent Humidity Alarm System & Optics ProtectionIncorporates dynamic internal moisture monitoring with a visual warning alarm, a high-capacity desiccant chamber, and moisture-proof optical coatings to preserve delicate KBr optics.
  • Tool-Free Plug-and-Play Accessory MountingSupports rapid interchange between ATR crystal units, specular reflection units, and gas sampling cells with precise positioning pins, eliminating optical recalibration during routine workflows.
  • Long-Life Air-Cooled IR Light Source (Made in USA)Includes a stable ceramic infrared light source imported from the USA, ensuring steady thermal emission, low drift, and minimal maintenance costs over long operational lifespans.
  • Ergonomic Push-Pull Sample ChamberDesigned with a spacious sample compartment (520 × 430 × 250 mm footprint) that minimizes atmospheric air disturbance during sample loading for rapid, repeatable scanning cycles.

Technical Specifications of FTIR Spectrometer

Product Model BRT-890 High-Performance FTIR Spectrometer
Wavenumber / Spectral Range 7800 cm⁻¹ to 350 cm⁻¹
Spectral Resolution & Repeatability Resolution: Better than 0.85 cm⁻¹; Wavelength Repeatability: Better than 0.5 cm⁻¹
Signal-to-Noise Ratio (SNR) & Accuracy 45,000:1 (Peak-to-Peak, 4 cm⁻¹, 1 min scan); Transmission Accuracy: Better than 0.05%
Interferometer & Beamsplitter DSP-Driven Non-Orthogonal Michelson Interferometer; KBr coated with Ge (Made in USA)
Detector & Light Source High-resolution DLATGS with moisture-proof coating; Long-life air-cooled IR source (Made in USA)
Electronics & Communication High-Speed USB 2.0 (USB 3.0 compatible); Real-time diagnostic monitoring
Dimensions & Instrument Weight 520 mm × 430 mm × 250 mm (L × W × H); Total Weight: 19 kg (41.89 lb)

Standard Package Accessories Included

  • Main Host Unit: BRT-890 High-Performance FTIR Spectrometer Unit (1 unit).
  • Core Optics Suite: Pre-installed US-imported KBr/Ge Beamsplitter & DLATGS Detector with Moisture-Proof Coating.
  • Sampling Module: Standard Transmission Sample Holder (Modular ATR and gas accessories optional).
  • Power & Interface Connectivity: AC Power Adapter, USB Communication Cable.
  • Maintenance & Calibration Kit: High-capacity desiccant replacement pack, protective dust cover, and system validation sample.
  • Software & Documentation: FTIR Spectral Analysis Software Suite, Comprehensive Spectral Library, Operating Manual, Certificate of Conformity, Warranty Card.

Testing Workflow & Target Applications

Standardized Testing Workflow:

  1. Power on the BRT-890 and open the analysis software; inspect the dynamic internal humidity status on the control panel.
  2. Mount the chosen sampling accessory (e.g., Diamond ATR crystal or Transmission cell) into the sample chamber.
  3. Collect a background spectrum to eliminate ambient atmospheric background interference (CO₂ and H₂O vapor).
  4. Place the sample on the optical interface and initiate a single-click spectral acquisition cycle.
  5. Run automated library matching to confirm substance identity or perform peak area integration for quantitative calibration reports.

Target Customer Applications:

  • Pharmaceutical research institutes, biomedical manufacturing QA/QC labs, and API formulation testing centers.
  • Petrochemical processing plants, organic synthesis research labs, and advanced polymer characterization facilities.
  • Food safety inspection agencies and environmental monitoring centers analyzing trace gas/water pollutants.
  • University chemistry departments, research institutes, and industrial failure analysis laboratories.

FTIR Spectrometer FAQ

Q1: What advantage does the 45,000:1 Signal-to-Noise Ratio (SNR) provide during testing?

A: A higher SNR of 45,000:1 produces extremely smooth spectral baselines with minimal background noise. This allows for clear detection of weak absorption bands, trace component concentrations, and subtle material impurities that lower-SNR instruments might miss.

Q2: How does the Digital Signal Processing (DSP) system improve interferometer performance?

A: The integrated DSP system continuously monitors and controls mirror movement within the non-orthogonal Michelson interferometer, maintaining precise optical alignment and rapid data processing for ultra-repeatable measurements.

Q3: How does the internal humidity alarm prevent instrument damage?

A: Internal KBr beamsplitters absorb moisture over time. The BRT-890’s humidity alarm system continuously tracks relative humidity inside the optical housing and alerts the operator when the desiccant needs changing, extending optic lifespan.

Reviews

There are no reviews yet.

Be the first to review “BRT-890 FTIR Spectrometer”

Your email address will not be published. Required fields are marked *