BRT AA1800 dedicated flame AAS with double-beam optics, 185Диапазон –900 нм, eight-lamp turret and titanium burner head. Full datasheet specifications.

Запрос сейчас

АДРЕС ЭЛЕКТРОННОЙ ПОЧТЫ

ИМЯ

ФАМИЛИЯ

WhatsApp

СООБЩЕНИЕ

Product overview

The BRT AA1800 is a dedicated flame atomic absorption spectrophotometer. It is built for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis, using a double-beam optical path, an eight-lamp turret and a titanium burner head.

BRT AAS instrument viewed from front left with open sample compartment and autosampler attached
Front-left three-quarter view of the BRT AAS system with the graphite furnace sampler fitted.

Key features across the series

  • Total-reflection optical system designed for high signal-to-noise performance.
  • Eight-lamp turret with 360° rotation and simultaneous preheating of 1–4 lamps.
  • Windows workstation software with automatic control, QA/QC functions, SD/RSD calculation and calibration-curve correlation checking.
  • Multiple data-processing modes including average, peak height, peak area and statistical analysis.
  • One-click database access for wavelength, спектральная полоса пропускания, lamp current, negative high voltage and energy-balance settings.

Optical system and photometric performance

ПараметрAA1800AA1900AA2000
Instrument typeFlame systemFlame & GFAA integratedFlame & GFAA integrated
Beam typeDouble-beamDouble-beamDouble-beam
Diffraction grating1800 lines/mm; blaze wavelength 250 нм1800 lines/mm; blaze wavelength 250 нм1800 lines/mm; blaze wavelength 250 нм
Диапазон длин волн185–900 нм185–900 нм185–900 нм
Спектральная полоса пропускания0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм
Точность длины волны±0.15 nm±0.20 nm±0.15 nm
Повторяемость длины волны≤0.05 nm≤0.10 nm≤0.05 nm
Spectral bandwidth deviation±0.02 nm±0.02 nm±0.02 nm
Lamp stand8 lamps; simultaneous preheating of 1–4 lamps8 lamps; simultaneous preheating of 1–4 lamps8 lamps; simultaneous preheating of 1–4 lamps
Front view of the BRT AAS with both housings, open sample compartment, cyan tubing and autosampler lid
Straight-on front view of the AAS with both atomization units visible.

Фотометрические характеристики

ПараметрAA1800AA1900AA2000
Reading modesTransmittance, поглощение, concentrationTransmittance, поглощение, concentrationTransmittance, поглощение, concentration
Photometric range0–125%T; −0.1–3.00 Abs0–125%T; −0.1–3.00 Abs0–125%T; −0.1–3.00 Abs
Базовая стабильность±0.002 Abs (steady 30 мин); ±0.004 Abs (dynamic 15 мин)±0.003 Abs (steady 30 мин); ±0.005 Abs (dynamic 15 мин)±0.002 Abs (steady 30 мин); ±0.004 Abs (dynamic 15 мин)
Background correctionD₂ lamp ≥40-fold (1 пресс); self-reversal ≥80-fold (1 пресс)D₂ lamp ≥40-fold (1 пресс)D₂ lamp ≥40-fold (1 пресс); self-reversal ≥80-fold (1 пресс)

Flame analysis

ПараметрAA1800AA1900AA2000
Characteristic concentration (Cu)≤0.02 μg/mL≤0.035 μg/mL≤0.02 μg/mL
Detection limit (Cu)≤0.004 μg/mL≤0.006 μg/mL≤0.004 μg/mL
Повторяемость (Cu)≤0.5%≤0.6%≤0.5%
ГорелкаTitanium burner headTitanium burner headTitanium burner head
NebulizerHigh-efficiency glass nebulizerHigh-efficiency glass nebulizerHigh-efficiency glass nebulizer
SafetyFlame gas & auxiliary gas abnormal-pressure protectionFlame gas & auxiliary gas abnormal-pressure protectionFlame gas & auxiliary gas abnormal-pressure protection

Titanium burner and nebulizer

AA1800 uses a titanium burner head with a high-efficiency glass nebulizer. Flame gas and auxiliary gas abnormal-pressure protection is standard.

Data processing

ПараметрAA1800AA1900AA2000
Concentration calculationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolation
Repeated measurements1–30 times; average, SD and RSD of absorbance/concentration1–30 times; average, SD and RSD of absorbance/concentration1–30 times; average, SD and RSD of absorbance/concentration

Accessories and physical data

ПараметрAA1800AA1900AA2000
Standard accessoriesCu lamp ×1; oil-free air compressor; software; USB flash driveCu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL)Cu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL)
Optional accessoriesOxygen-enriched high-temperature flame; hydride generator; audit-trail software; flame autosamplerOxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosamplerOxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler
Power supplyпеременного тока 220 В, 50/60 Гцпеременного тока 220 В, 50/60 Гцпеременного тока 220 В, 50/60 Гц
External size (W×D×H)830×650×560 mm830×650×560 mm830×650×560 mm
Package size (W×D×H)1010×780×830 mm1010×780×830 mm1010×780×830 mm
Net weight85 кг120 кг125 кг
Gross weight135 кг183 кг183 кг

Service connections and installation

Close-up of BRT AAS rear panel with cooling louvres, brand plate, mains inlet and gas and water connectors
Detail of the rear panel with power inlet and gas/water connectors.

Rear-panel mains inlet, gas and water connectors are grouped for bench installation. The instrument sits on vibration-isolation feet; unpacking and leveling are required before atomizer alignment.

Frequently asked questions

What elements can this AAS determine?

The series is specified for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. Element-specific detection limits are supplied for Cu and Cd in the datasheet; limits for other elements must be confirmed against your application.

What is the wavelength range?

All three models cover 185–900 nm with a 1800 lines/mm grating blazed at 250 нм.

How many lamps can be fitted?

The turret holds eight lamps and can preheat 1–4 lamps simultaneously.

Does AA1800 include a graphite furnace?

Нет. AA1800 is a dedicated flame system. For graphite furnace atomization, specify AA1900 or AA2000.

Which background correction is fitted?

AA1800 and AA2000 specify D₂ lamp ≥40-fold (1 пресс) and self-reversal ≥80-fold (1 пресс). AA1900 specifies D₂ lamp ≥40-fold (1 пресс).

What data processing is available?

Standard curve with six linear/non-linear fitting methods, standard addition and interpolation; 1–30 repeated measurements with average, SD and RSD.

What power supply is required?

переменного тока 220 В, 50/60 Hz for all three models.

Related models

Compare also: BRT AA1900 BRT AA2000.

See the complete BRT AAS series comparison.

Request a quotation

Specify your element list, sample matrix, required detection limits and atomization mode (flame only or flame + graphite furnace). BRT will confirm the configuration, accessory set and delivery terms. Contact info@brt-test.com or WhatsApp +86 156 0405 7553.