Compare the BRT AA1800, AA1900 and AA2000 atomic absorption spectrophotometer series — optical performance, flame and graphite furnace data, accessories and physical specifications.

Запрос сейчас

АДРЕС ЭЛЕКТРОННОЙ ПОЧТЫ

ИМЯ

ФАМИЛИЯ

WhatsApp

СООБЩЕНИЕ

Product overview

BRT atomic absorption spectrophotometer systems are benchtop AAS instruments for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. The series covers three configurations: AA1800 (flame only), AA1900 and AA2000 (flame and graphite furnace atomization in one system). All three share a double-beam optical path, an 185–900 nm wavelength range, an eight-lamp turret and Windows-based workstation software. This page brings the full series specification set together so you can compare models before requesting a quotation.

Choose your configuration

Each model has its own product page with the full specification table. Start from the model that matches your atomization requirement.

BRT atomic absorption spectrometer installed on a clean laboratory bench with glassware and workstation monitors behind
The AAS shown installed on a bench in a modern analytical laboratory.

Key features across the series

  • Total-reflection optical system designed for high signal-to-noise performance.
  • Eight-lamp turret with 360° rotation and simultaneous preheating of 1–4 lamps.
  • Windows workstation software with automatic control, QA/QC functions, SD/RSD calculation and calibration-curve correlation checking.
  • Multiple data-processing modes including average, peak height, peak area and statistical analysis.
  • One-click database access for wavelength, спектральная полоса пропускания, lamp current, negative high voltage and energy-balance settings.

Series specification — optical system and photometric performance

ПараметрAA1800AA1900AA2000
Instrument typeFlame systemFlame & GFAA integratedFlame & GFAA integrated
Beam typeDouble-beamDouble-beamDouble-beam
Diffraction grating1800 lines/mm; blaze wavelength 250 нм1800 lines/mm; blaze wavelength 250 нм1800 lines/mm; blaze wavelength 250 нм
Диапазон длин волн185–900 нм185–900 нм185–900 нм
Спектральная полоса пропускания0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм
Точность длины волны±0.15 nm±0.20 nm±0.15 nm
Повторяемость длины волны≤0.05 nm≤0.10 nm≤0.05 nm
Spectral bandwidth deviation±0.02 nm±0.02 nm±0.02 nm
Lamp stand8 lamps; simultaneous preheating of 1–4 lamps8 lamps; simultaneous preheating of 1–4 lamps8 lamps; simultaneous preheating of 1–4 lamps

Series specification — photometric performance

ПараметрAA1800AA1900AA2000
Reading modesTransmittance, поглощение, concentrationTransmittance, поглощение, concentrationTransmittance, поглощение, concentration
Photometric range0–125%T; −0.1–3.00 Abs0–125%T; −0.1–3.00 Abs0–125%T; −0.1–3.00 Abs
Базовая стабильность±0.002 Abs (steady 30 мин); ±0.004 Abs (dynamic 15 мин)±0.003 Abs (steady 30 мин); ±0.005 Abs (dynamic 15 мин)±0.002 Abs (steady 30 мин); ±0.004 Abs (dynamic 15 мин)
Background correctionD₂ lamp ≥40-fold (1 пресс); self-reversal ≥80-fold (1 пресс)D₂ lamp ≥40-fold (1 пресс)D₂ lamp ≥40-fold (1 пресс); self-reversal ≥80-fold (1 пресс)

Series specification — flame analysis

ПараметрAA1800AA1900AA2000
Characteristic concentration (Cu)≤0.02 μg/mL≤0.035 μg/mL≤0.02 μg/mL
Detection limit (Cu)≤0.004 μg/mL≤0.006 μg/mL≤0.004 μg/mL
Повторяемость (Cu)≤0.5%≤0.6%≤0.5%
ГорелкаTitanium burner headTitanium burner headTitanium burner head
NebulizerHigh-efficiency glass nebulizerHigh-efficiency glass nebulizerHigh-efficiency glass nebulizer
SafetyFlame gas & auxiliary gas abnormal-pressure protectionFlame gas & auxiliary gas abnormal-pressure protectionFlame gas & auxiliary gas abnormal-pressure protection

Series specification — graphite furnace analysis

ПараметрAA1800AA1900AA2000
Characteristic mass—Cd ≤0.6 pg; Cu ≤20 pgCd ≤0.5 pg; Cu ≤20 pg
Detection limit—Cd ≤1.0 pg; Cu ≤25 pgCd ≤0.8 pg; Cu ≤25 pg
Повторяемость (Cd)—≤3%≤2.5%
Диапазон температур—RT–3000 °CRT–3000 °C
Heating rate—Max. 2000 °C/sMax. 2000 °C/s
Safety—Cooling-water flow, protective-gas pressure, furnace-body temperature, power-supply temperature and graphite-tube installation alarmsCooling-water flow, protective-gas pressure, furnace-body temperature, power-supply temperature and graphite-tube installation alarms
Overhead view of the BRT AAS open sample compartment with graphite furnace workhead and white sample bottles
Overhead view of the open sample compartment and graphite furnace workhead.

Series specification — data processing

ПараметрAA1800AA1900AA2000
Concentration calculationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolation
Repeated measurements1–30 times; average, SD and RSD of absorbance/concentration1–30 times; average, SD and RSD of absorbance/concentration1–30 times; average, SD and RSD of absorbance/concentration

Series specification — accessories and physical data

ПараметрAA1800AA1900AA2000
Standard accessoriesCu lamp ×1; oil-free air compressor; software; USB flash driveCu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL)Cu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL)
Optional accessoriesOxygen-enriched high-temperature flame; hydride generator; audit-trail software; flame autosamplerOxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosamplerOxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler
Power supplyпеременного тока 220 В, 50/60 Гцпеременного тока 220 В, 50/60 Гцпеременного тока 220 В, 50/60 Гц
External size (W×D×H)830×650×560 mm830×650×560 mm830×650×560 mm
Package size (W×D×H)1010×780×830 mm1010×780×830 mm1010×780×830 mm
Net weight85 кг120 кг125 кг
Gross weight135 кг183 кг183 кг

Flame AAS or flame + graphite furnace: which configuration?

Выбирать AA1800 when the required concentration range is within flame AAS capability and a graphite furnace is not needed. Выбирать AA1900 или AA2000 when lower mass detection limits are required — the datasheet lists graphite furnace detection limits of Cd ≤1.0 pg (AA1900) and Cd ≤0.8 pg (AA2000), against flame Cu detection limits of ≤0.006 μg/mL (AA1900) and ≤0.004 μg/mL (AA2000). All three models share the same 185–900 nm optical range, eight-lamp turret and AC 220 V supply.

Workhead and sampler

Close-up of graphite furnace workhead, injection assembly and sample bottle inside the BRT AAS sample compartment
Close-up of the graphite furnace workhead and injection assembly inside the sample compartment.
Close-up of cylindrical autosampler module with matte black lid and vertical Ignition, TurnOff, AutoZero, StartTest buttons
Detail of the autosampler lid and the vertical control buttons.

Installation connections

Close-up of BRT AAS rear panel with cooling louvres, brand plate, mains inlet and gas and water connectors
Detail of the rear panel with power inlet and gas/water connectors.

Other views

BRT atomic absorption spectrometer seen from front right, showing the black circular autosampler lid and connection panel
Front-right view highlighting the autosampler lid and rear signal connections.
Left side of the BRT AAS showing cooling vent, oval brand plate, open workhead and vertical control buttons
Left-side view with cooling louvres, brand plate and control buttons labelled.
Rear-left view of the BRT AAS showing mains inlet, gas and water connectors and red isolation feet
Rear view showing power inlet, gas/water connectors and shock-absorbing feet.

Frequently asked questions

What elements can this AAS determine?

The series is specified for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. Element-specific detection limits are supplied for Cu and Cd in the datasheet; limits for other elements must be confirmed against your application.

What is the wavelength range?

All three models cover 185–900 nm with a 1800 lines/mm grating blazed at 250 нм.

How many lamps can be fitted?

The turret holds eight lamps and can preheat 1–4 lamps simultaneously.

What does the graphite furnace add?

Graphite furnace atomization extends the instrument to lower mass detection limits — the datasheet lists Cd ≤1.0 pg (AA1900) and Cd ≤0.8 pg (AA2000), with a temperature range up to 3000 °С.

Which background correction is fitted?

AA1800 and AA2000 specify D₂ lamp ≥40-fold (1 пресс) and self-reversal ≥80-fold (1 пресс). AA1900 specifies D₂ lamp ≥40-fold (1 пресс).

What data processing is available?

Standard curve with six linear/non-linear fitting methods, standard addition and interpolation; 1–30 repeated measurements with average, SD and RSD.

What power supply is required?

переменного тока 220 В, 50/60 Hz for all three models.

Request a quotation

Specify your element list, sample matrix, required detection limits and atomization mode (flame only or flame + graphite furnace). BRT will confirm the configuration, accessory set and delivery terms. Contact info@brt-test.com or WhatsApp +86 156 0405 7553.

Отзывы

Отзывов пока нет.

Будьте первым, кто оставил отзыв на «Atomic Absorption Spectrophotometer: Flame and GFAA Systems»

Ваш адрес email не будет опубликован. Обязательные поля помечены *