BRT AA1800 dedicated flame AAS with double-beam optics, 185Диапазон –900 нм, eight-lamp turret and titanium burner head. Full datasheet specifications.
- Product overview
- Key features across the series
- Optical system and photometric performance
- Фотометрические характеристики
- Flame analysis
- Titanium burner and nebulizer
- Data processing
- Accessories and physical data
- Service connections and installation
- Frequently asked questions
- Related models
- Request a quotation
Product overview
The BRT AA1800 is a dedicated flame atomic absorption spectrophotometer. It is built for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis, using a double-beam optical path, an eight-lamp turret and a titanium burner head.

Key features across the series
- Total-reflection optical system designed for high signal-to-noise performance.
- Eight-lamp turret with 360° rotation and simultaneous preheating of 1–4 lamps.
- Windows workstation software with automatic control, QA/QC functions, SD/RSD calculation and calibration-curve correlation checking.
- Multiple data-processing modes including average, peak height, peak area and statistical analysis.
- One-click database access for wavelength, спектральная полоса пропускания, lamp current, negative high voltage and energy-balance settings.
Optical system and photometric performance
| Параметр | AA1800 | AA1900 | AA2000 |
|---|---|---|---|
| Instrument type | Flame system | Flame & GFAA integrated | Flame & GFAA integrated |
| Beam type | Double-beam | Double-beam | Double-beam |
| Diffraction grating | 1800 lines/mm; blaze wavelength 250 нм | 1800 lines/mm; blaze wavelength 250 нм | 1800 lines/mm; blaze wavelength 250 нм |
| Диапазон длин волн | 185–900 нм | 185–900 нм | 185–900 нм |
| Спектральная полоса пропускания | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 нм |
| Точность длины волны | ±0.15 nm | ±0.20 nm | ±0.15 nm |
| Повторяемость длины волны | ≤0.05 nm | ≤0.10 nm | ≤0.05 nm |
| Spectral bandwidth deviation | ±0.02 nm | ±0.02 nm | ±0.02 nm |
| Lamp stand | 8 lamps; simultaneous preheating of 1–4 lamps | 8 lamps; simultaneous preheating of 1–4 lamps | 8 lamps; simultaneous preheating of 1–4 lamps |

Фотометрические характеристики
| Параметр | AA1800 | AA1900 | AA2000 |
|---|---|---|---|
| Reading modes | Transmittance, поглощение, concentration | Transmittance, поглощение, concentration | Transmittance, поглощение, concentration |
| Photometric range | 0–125%T; −0.1–3.00 Abs | 0–125%T; −0.1–3.00 Abs | 0–125%T; −0.1–3.00 Abs |
| Базовая стабильность | ±0.002 Abs (steady 30 мин); ±0.004 Abs (dynamic 15 мин) | ±0.003 Abs (steady 30 мин); ±0.005 Abs (dynamic 15 мин) | ±0.002 Abs (steady 30 мин); ±0.004 Abs (dynamic 15 мин) |
| Background correction | D₂ lamp ≥40-fold (1 пресс); self-reversal ≥80-fold (1 пресс) | D₂ lamp ≥40-fold (1 пресс) | D₂ lamp ≥40-fold (1 пресс); self-reversal ≥80-fold (1 пресс) |
Flame analysis
| Параметр | AA1800 | AA1900 | AA2000 |
|---|---|---|---|
| Characteristic concentration (Cu) | ≤0.02 μg/mL | ≤0.035 μg/mL | ≤0.02 μg/mL |
| Detection limit (Cu) | ≤0.004 μg/mL | ≤0.006 μg/mL | ≤0.004 μg/mL |
| Повторяемость (Cu) | ≤0.5% | ≤0.6% | ≤0.5% |
| Горелка | Titanium burner head | Titanium burner head | Titanium burner head |
| Nebulizer | High-efficiency glass nebulizer | High-efficiency glass nebulizer | High-efficiency glass nebulizer |
| Safety | Flame gas & auxiliary gas abnormal-pressure protection | Flame gas & auxiliary gas abnormal-pressure protection | Flame gas & auxiliary gas abnormal-pressure protection |
Titanium burner and nebulizer
AA1800 uses a titanium burner head with a high-efficiency glass nebulizer. Flame gas and auxiliary gas abnormal-pressure protection is standard.
Data processing
| Параметр | AA1800 | AA1900 | AA2000 |
|---|---|---|---|
| Concentration calculation | Standard curve (6 linear/non-linear fitting methods), standard addition and interpolation | Standard curve (6 linear/non-linear fitting methods), standard addition and interpolation | Standard curve (6 linear/non-linear fitting methods), standard addition and interpolation |
| Repeated measurements | 1–30 times; average, SD and RSD of absorbance/concentration | 1–30 times; average, SD and RSD of absorbance/concentration | 1–30 times; average, SD and RSD of absorbance/concentration |
Accessories and physical data
| Параметр | AA1800 | AA1900 | AA2000 |
|---|---|---|---|
| Standard accessories | Cu lamp ×1; oil-free air compressor; software; USB flash drive | Cu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL) | Cu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL) |
| Optional accessories | Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; flame autosampler | Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler | Oxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler |
| Power supply | переменного тока 220 В, 50/60 Гц | переменного тока 220 В, 50/60 Гц | переменного тока 220 В, 50/60 Гц |
| External size (W×D×H) | 830×650×560 mm | 830×650×560 mm | 830×650×560 mm |
| Package size (W×D×H) | 1010×780×830 mm | 1010×780×830 mm | 1010×780×830 mm |
| Net weight | 85 кг | 120 кг | 125 кг |
| Gross weight | 135 кг | 183 кг | 183 кг |
Service connections and installation

Rear-panel mains inlet, gas and water connectors are grouped for bench installation. The instrument sits on vibration-isolation feet; unpacking and leveling are required before atomizer alignment.
Frequently asked questions
What elements can this AAS determine?
The series is specified for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. Element-specific detection limits are supplied for Cu and Cd in the datasheet; limits for other elements must be confirmed against your application.
What is the wavelength range?
All three models cover 185–900 nm with a 1800 lines/mm grating blazed at 250 нм.
How many lamps can be fitted?
The turret holds eight lamps and can preheat 1–4 lamps simultaneously.
Does AA1800 include a graphite furnace?
Нет. AA1800 is a dedicated flame system. For graphite furnace atomization, specify AA1900 or AA2000.
Which background correction is fitted?
AA1800 and AA2000 specify D₂ lamp ≥40-fold (1 пресс) and self-reversal ≥80-fold (1 пресс). AA1900 specifies D₂ lamp ≥40-fold (1 пресс).
What data processing is available?
Standard curve with six linear/non-linear fitting methods, standard addition and interpolation; 1–30 repeated measurements with average, SD and RSD.
What power supply is required?
переменного тока 220 В, 50/60 Hz for all three models.
Related models
Compare also: BRT AA1900 BRT AA2000.
See the complete BRT AAS series comparison.
Request a quotation
Specify your element list, sample matrix, required detection limits and atomization mode (flame only or flame + graphite furnace). BRT will confirm the configuration, accessory set and delivery terms. Contact info@brt-test.com or WhatsApp +86 156 0405 7553.