BRT-5800UV UV Vis Spectrophotometer is a 17 kg benchtop double-beam instrument featuring a 190–1100 nm spectral range, 1.8 nm bandwidth, C-T monochromator with 1200 lines/mm grating, and an extended measuring range up to 4.000 Abs. Equipped with dual tungsten/deuterium lamps, a 320×240 blue LCD screen, 200-dataset memory, 4 quartz/4 glass cuvettes, USB connectivity, and LPT printer output, it delivers reliable photometric and quantitative analysis.
The BRT-5800UV UV Vis Spectrophotometer is a high-precision double-beam analytical instrument built on a Czerny-Turner (C-T) monochromator optical architecture, a 1200 lines/mm holographic grating, and a high-sensitivity silicon photocell detector. Engineered for demanding pharmaceutical research, environmental compliance labs, chemical quality control facilities, and molecular biology institutes, it delivers an extended linear absorbance range up to 4.000 Abs across the 190 nm to 1100 nm spectral spectrum with a 1.8 nm bandwidth, ±0.3 nm wavelength accuracy, and 0.2 nm wavelength repeatability.
Featuring dual deuterium and tungsten halogen light sources with adjustable switching points, this research-grade UV Vis Spectrophotometer guarantees superior transmittance accuracy (±0.3%T) and exceptional optical baseline stability. Equipped with a 320×240 blue LCD screen, automated startup wavelength calibration, onboard memory for 200 datasets and standard curves, high-speed USB data export, and LPT parallel printer output, the 17 kg BRT-5800UV provides accurate quantitative analysis and routine photometric testing.
UV Vis Spectrophotometer Measurement & Analysis Capabilities
This double-beam C-T monochromator spectrophotometer equips analytical chemists to execute complex photometric, quantitative, and kinetic testing workflows with automated baseline drift monitoring:
| Analysis Mode | Methodology & Operational Scope | Primary Testing Application |
|---|---|---|
| Photometric Measurement | Direct evaluation of Absorbance (-0.301 to 4.000 Abs) and Transmittance (0 to 200%T) at fixed user-defined wavelengths across 190–1100 nm | High-density sample optical screening, chemical raw material verification, and solution clarity testing |
| Quantitative Concentration Profiling | Concentration calculations using factor coefficients ($C = KA + B$) or multi-point linear calibration standard curves with automatic regression fitting | Pharmaceutical active ingredient assays, environmental water testing (COD, nitrate, heavy metals), and chemical concentration checks |
| PC-Driven Kinetics & Spectral Analysis | Time-course dynamic tracking, multi-wavelength testing, and full spectral scanning using optional PC analysis software via USB connection | Enzymatic reaction rates, dynamic degradation monitoring, nucleic acid/protein assays, and complex chemical characterization |
Technological Features of BRT-5800UV UV Vis Spectrophotometer
- Double-Beam Optics & C-T Monochromator ArchitectureCombines a double-beam optical layout with a Czerny-Turner monochromator and 1200 lines/mm holographic grating to eliminate optical drift and ensure maximum signal purity.
- Extended Absorbance Range (Up to 4.000 Abs)Provides an extended photometric dynamic range from -0.301 to 4.000 Abs, allowing accurate measurement of highly absorbing samples without requiring immediate dilution.
- Narrow 1.8 nm Bandwidth & High Resolution (0.1 nm Display)Delivers a tight 1.8 nm optical bandwidth across 190–1100 nm with 0.1 nm readout resolution, providing ±0.3 nm wavelength accuracy for sharp peak isolation.
- Dual Light Sources with Adjustable Switching PointsFeatures imported deuterium and tungsten halogen lamps with customizable switching points and microcomputer control to maximize lamp service life and operational stability.
- Intelligent Startup Calibration & Real-Time Stability MonitoringAutomates wavelength calibration, 0A / 100%T zeroing upon startup, and actively monitors baseline stability throughout long testing sequences.
- Dual Output Ports (USB PC Interface & LPT Parallel Port)Equipped with a USB port for streaming digital data to optional PC analysis software and an LPT parallel port for outputting test results directly to dedicated printers.
Technical Specifications of UV Vis Spectrophotometer
| Product Model | BRT-5800UV Dual Beam UV Vis Spectrophotometer |
| Optical System & Monochromator | Double Beam Optics, C-T Monochromator, 1200 lines/mm Holographic Grating |
| Wavelength Spectrum & Bandwidth | 190 nm to 1100 nm; Spectral Bandwidth: 1.8 nm; Wavelength Resolution: 0.1 nm |
| Wavelength Accuracy & Repeatability | Accuracy: ±0.3 nm; Repeatability: 0.2 nm |
| Photometric Range & Accuracy | 0 to 200%T, -0.301 to 4.000 Abs, -9999 to 9999 C; Transmittance Accuracy: ±0.3%T |
| Light Sources & Detector | Tungsten Halogen Lamp & Imported Deuterium Lamp; Silicon Photocell Detector |
| Display & User Interface | 320 × 240 Blue LCD Display Screen; Light-Touch Button Panel |
| Data Output & Memory Storage | Stores 200 Datasets & Standard Curves; USB Interface, LPT Parallel Printer Port |
| Dimensions & Instrument Weight | 545 × 450 × 235 mm (L × W × H); Total Weight: 17 kg (37.48 lb) |
Standard Package Accessories Included
- Main Host Unit: BRT-5800UV Double Beam UV Vis Spectrophotometer (1 unit).
- Sample Cell Holder: Fixed 2-Trench Cuvette Holder.
- Quartz Cuvettes: 10 mm Standard Quartz Cuvettes (4 pcs for Ultraviolet spectrum testing).
- Glass Cuvettes: 10 mm Standard Glass Cuvettes (4 pcs for Visible spectrum testing).
- Power & Data Connectivity: Dual-Voltage AC Power Cable, USB Interface Cable.
- Documentation & Software: Operating Manual, Quality Certificate, Warranty Card.
Testing Workflow & Target Applications
Standardized Testing Workflow:
- Power on the BRT-5800UV; allow the microcomputer to initialize lamp switching, dark current zeroing, and startup wavelength calibration.
- Select Photometric or Quantitative mode on the 320×240 blue LCD display menu.
- Place a reference solvent blank into the reference position of the 2-trench holder to execute 0A / 100%T baseline zeroing.
- Place the sample into the testing path to obtain direct absorbance readings up to 4.000 Abs or compute concentrations using pre-stored calibration curves.
- Save measurement results (up to 200 datasets) in internal memory, export via USB interface to optional PC software, or print reports via the LPT parallel printer port.
Target Customer Applications:
- Pharmaceutical testing laboratories, active pharmaceutical ingredient (API) assay facilities, and QA/QC centers.
- Environmental inspection agencies (water quality, heavy metal detection, COD, and pollutant analysis).
- Biochemistry laboratories, molecular biology research facilities, and university testing bays.
- Chemical plants, food safety testing centers, and agricultural analysis stations.
UV Vis Spectrophotometer FAQ
Q1: What are the analytical advantages of the 4.000 Abs measuring range on the BRT-5800UV?
A: An extended range up to 4.000 Abs allows technicians to measure dense or highly concentrated samples directly without performing manual serial dilutions, preserving sample integrity and reducing preparation errors.
Q2: How does the double-beam C-T monochromator optical system benefit daily lab testing?
A: The double-beam C-T monochromator design splits light to continuously compensate for lamp drift and environmental changes. This guarantees high baseline flatness, minimal stray light, and excellent photometric reproducibility.
Q3: What analytical modes are supported when connecting the instrument to PC software via USB?
A: Connecting to optional PC software via USB enables continuous spectrum scanning, dynamic time-course reaction kinetics, multi-wavelength testing, and customizable GLP laboratory report generation.












Reviews
There are no reviews yet.