BRT-3200UV UV Vis Spectrophotometer is a high-precision double-beam benchtop instrument featuring a 190–1100 nm spectral range, narrow 1.8 nm bandwidth, 1200 lines/mm holographic grating, and ≤0.1 nm wavelength repeatability. Equipped with a 320×240 bilingual LCD screen, dual socket-type tungsten/deuterium lamps, onboard memory, included 8 GB USB flash drive, GLP PC software, and LPT printer output, it delivers accurate photometric, quantitative, kinetic, full-spectrum scanning, and DNA/protein assays.

SKU: BRT-3200UV, Categories: ,
Inquiry Now

EMAIL ADDRESS

FIRST NAME

LAST NAME

whatsapp

MESSAGE

The BRT-3200UV UV Vis Spectrophotometer is a high-performance double-beam analytical instrument engineered for precision photometric profiling, full spectral scanning, kinetics tracking, and bio-molecular quantification. Designed for advanced pharmaceutical research, molecular biology institutes, environmental monitoring laboratories, and chemical QA/QC facilities, it provides extended spectral coverage across the 190 nm to 1100 nm range with a narrow 1.8 nm spectral bandwidth, ±0.3 nm wavelength accuracy, and ≤0.1 nm wavelength repeatability.

Featuring an advanced optical architecture with a 1200 lines/mm holographic grating, real-time light source monitoring, socket-type tungsten halogen and imported deuterium lamps, and high-sensitivity detectors, this versatile UV Vis Spectrophotometer delivers outstanding transmittance accuracy (±0.3%T) and low optical stray light. Equipped with a 320×240 bilingual dot-matrix LCD display, built-in USB storage with an included 8 GB USB flash drive, GLP-compliant analysis software, and an LPT printer port, the 20 kg BRT-3200UV optimizes high-throughput laboratory analysis.


UV Vis Spectrophotometer Measurement & Analysis Capabilities

This dual-beam analytical instrument offers a complete suite of onboard measurement modes and GLP-compliant PC software capabilities for complex sample evaluation:

Analysis Mode Methodology & Operational Scope Primary Testing Application
Full Spectrum Scanning Full spectral absorption and transmittance scanning across the 190–1100 nm range with automatic peak detection and spectrum plotting Peak characterization, compound verification, raw material identity testing, and impurity identification
Quantitative Concentration Profiling Quantitative analysis via standard coefficient input or multi-point linear curve fitting using up to 10 standard samples Pharmaceutical active ingredient assays, chemical solution concentration, and environmental water testing
Kinetic Reaction Rate Analysis Time-course dynamic tracking at fixed wavelengths with customizable graph coordinates and automated calculation of reaction rates (ΔA/Δt) Enzyme activity assays, biochemical kinetic tracking, dynamic degradation, and thermal stability studies
DNA/Protein & Multi-Wavelength Assays Built-in bio-assay formulas for direct concentration and purity ratio calculations (260/280 nm), plus automated multi-wavelength photometric measurements Nucleic acid purity determination, protein concentration assays, and multi-component solution testing

Technological Features of BRT-3200UV UV Vis Spectrophotometer

  • High Optical Resolution (1.8 nm Bandwidth & 1200 L/mm Grating)

    Features a 1.8 nm optical bandwidth combined with a 1200 lines/mm holographic grating to ensure high energy throughput, minimal stray light, and sharp resolution of overlapping peaks.

  • Superior Wavelength Precision (±0.3 nm Accuracy, ≤0.1 nm Repeatability)

    Provides tight wavelength repeatability (≤0.1 nm) with 0.1 nm digital display resolution for accurate baseline stability during long scanning runs.

  • 320×240 Bilingual LCD & Real-Time Light Source Monitoring

    Displays full spectrum curves and regression graphs directly on screen with switchable English/Chinese menus, backed by socket-type light sources that allow replacement without realignment.

  • Expanded Memory & Direct USB Flash Drive Storage

    Features large onboard internal memory and includes an 8 GB USB flash drive for exporting measurement curves and data files with customizable file names.

  • Spacious Sample Chamber (5 mm to 100 mm Cuvette Range)

    Accommodates cell holders for cuvettes from 5 mm up to 100 mm optical pathlength, making it versatile for both trace biological samples and diluted environmental liquids.

  • Standard GLP Analysis Software & LPT Parallel Output

    Comes standard with Mapada professional analysis software featuring GLP self-identification for full PC operation, alongside an LPT parallel printer port for direct printouts.


Technical Specifications of UV Vis Spectrophotometer

Product Model BRT-3200UV Double Beam UV Vis Spectrophotometer
Optical System & Grating Double Beam Optics, 1200 lines/mm Holographic Grating
Wavelength Spectrum & Bandwidth 190 nm to 1100 nm; Spectral Bandwidth: 1.8 nm; Wavelength Resolution: 0.1 nm
Wavelength Accuracy & Repeatability Accuracy: ±0.3 nm; Repeatability: ≤0.1 nm
Photometric Range & Accuracy 0 to 200%T, -0.301 to 3.000 Abs, -9999 to 9999 C; Transmittance Accuracy: ±0.3%T
Light Sources & Detector Socket-type Tungsten Halogen & Imported Deuterium Lamps; High-Sensitivity Detector
Data Storage & Connectivity Large Onboard Storage, USB Host Port (8 GB Flash Drive Included), USB PC Interface, LPT Parallel Printer Port
Dimensions & Instrument Weight 590 × 420 × 260 mm (W × D × H); Total Weight: 20 kg (44.09 lb)

Standard Package Accessories Included

  • Main Host Unit: BRT-3200UV Double Beam UV Vis Spectrophotometer (1 unit).
  • Quartz Cuvettes: 10 mm Standard Quartz Cuvettes (2 pcs for UV spectrum testing).
  • Glass Cuvettes: 10 mm Standard Glass Cuvettes (4 pcs for Visible spectrum testing).
  • Storage Accessories: 8 GB USB Flash Drive (1 pc).
  • Sample Cell Holder: Standard Multi-Position Cell Holder.
  • Power & PC Connectivity: AC Power Cable, USB Connection Cable, Standard Mapada Analysis Software.
  • Documentation: User Operation Manual, Quality Certificate, Warranty Card.

Testing Workflow & Target Applications

Standardized Testing Workflow:

  1. Power on the BRT-3200UV; the system automatically performs self-testing, dark current zeroing, and optical baseline calibration.
  2. Select your analytical mode (Photometer, Quantitative, Kinetics, Spectrum Scanning, or DNA/Protein) from the 320×240 bilingual LCD menu.
  3. Insert a reference blank cuvette into the optical path to trigger automated 0A / 100%T baseline zeroing.
  4. Place test samples in the cell holder or connect via USB to execute PC-driven spectrum scanning, multi-wavelength testing, and report generation using Mapada software.
  5. Save measurement data directly to internal memory or export to the included 8 GB USB flash drive, or output printouts via the LPT parallel port.

Target Customer Applications:

  • Molecular biology, biochemistry, and life science research laboratories (DNA, RNA, and protein purity assays).
  • Pharmaceutical manufacturing QA/QC bays, active ingredient testing, and formulation development labs.
  • Environmental inspection agencies (water purity, heavy metal quantification, COD, and organic pollutant analysis).
  • University chemistry departments, research centers, and food & beverage quality testing laboratories.

UV Vis Spectrophotometer FAQ

Q1: What are the primary advantages of a double-beam optical system on the BRT-3200UV?

A: A double-beam optical layout continuously splits light between a reference path and a sample path. This design compensates for light source fluctuations and environmental drift in real time, delivering higher baseline stability, accuracy, and reproducibility during long spectral scans.

Q2: Does the BRT-3200UV require manual alignment when replacing lamps?

A: No. The BRT-3200UV features socket-type light sources (tungsten halogen and imported deuterium lamps) that allow quick plug-and-play replacement without complex optical alignment.

Q3: What analytical features does the standard Mapada software offer?

A: The standard analysis software supports GLP self-identification, continuous full-spectrum scanning, quantitative curve fitting, time-course enzyme kinetics (ΔA/Δt), multi-wavelength testing, and DNA/protein assays (260/280 nm) with standardized report generation.

Reviews

There are no reviews yet.

Be the first to review “BRT-3200UV UV Vis Spectrophotometer”