NH-XL Vertical Integrated Fire Resistance Test Furnace strictly complies with GB/T 9978, GB 12955-2024, GB 16809-2024, و ايزو 834-1 المعايير. Features a 3.0m × 3.0m × 1.2m cavity, lightweight high-alumina zirconia fiber suspended lining (up to 1300°C), 8 proportional gas burners, closed-loop pressure control, and automated PC data logging for fire doors, windows, shutters, and partition wall integrity & insulation testing.
- Vertical Comprehensive Fire-Resistance Test Furnace Compliance & المعايير
- Technological Features of H-XL Fire Resistance Test Furnace
- Technical Specifications of Vertical Comprehensive Fire-Resistance Test Furnace
- System Architecture & Testing Workflow of H-XL Fire Resistance Test Furnace
- H-XL Vertical Comprehensive Fire-Resistance Test Furnace FAQ
- جهاز اختبار عدم الاحتراق JBR20
- JCKR Building Material Combustibility Test Apparatus for SINGLE FLAME SOURCE TESTING
- بي دي سي ال-01 جهاز اختبار التدفق الحراري المشع
- SPCZ-06 رغوة بلاستيكية عمودية & جهاز اختبار الاحتراق الأفقي
ال NH-XL Vertical Integrated Fire Resistance Test Furnace (Vertical Comprehensive Fire-Resistance Test Furnace) is a full-scale, automated laboratory testing system engineered to evaluate the fire-resistance limit, thermal insulation performance, and structural integrity of vertical fire-partition walls, doors, windows, glass, roller shutters, and check valves/non-return valves. It strictly complies with ايزو 834-1/4/8, في 1363-1, في 1634-1, BS 476 (Parts 20/22), ASTM E119, أول 263, and mandatory national standards جيجابايت/ت 9978 و GB 12955-2024.
Built with a robust enamel-coated steel outer shell, lightweight high-alumina fiber suspended furnace body, zirconium-fiber block insulation capable of withstanding up to 1300°C, an 8-burner proportional gas combustion array, and automatic closed-loop pressure/temperature control, this heavy-duty Fire Resistance Testing Furnace provides authoritative compliance data for building material manufacturers, third-party fire testing laboratories, marine classification societies, and construction quality inspection bureaus.
Vertical Comprehensive Fire-Resistance Test Furnace Compliance & المعايير
This vertical fire resistance testing furnace allows certified laboratories to perform formal fire limit assessments across global building, marine, and door/window safety standards:
| الكود القياسي | العنوان القياسي & نِطَاق | تطبيق الاختبار الأساسي |
|---|---|---|
| ايزو 834-1 / 4 / 8 & BS 476-20/22 | Fire-resistance tests for elements of building construction — General requirements & vertical separating elements | International benchmark for standard time-temperature fire curve compliance and vertical partition testing |
| في 1363-1 & في 1634-1/3 | Fire resistance tests — General requirements & Fire resistance test for door, shutter assemblies and openable windows | European CE/CPR qualification testing for fire doors, shutters, window assemblies, and non-return valves |
| ASTM E119 & أول 263 | Standard Test Methods for Fire Tests of Building Construction and Materials | North American vertical partition wall and structural element fire endurance testing |
| GB/T 9978.1~4 & GB 12955-2024 | Fire-resistance tests for building construction elements & Fire doors mandatory specification | Mandatory Chinese national standard for fire doors, shutters, partition panels, and check/non-return valves |
| IMO FTP Code Part 3 | International Code for Application of Fire Test Procedures — Test for “أ”, “B” و “F” Class Divisions | Marine fire safety compliance for shipboard vertical bulkheads, fire doors, and exhaust dampers |
Technological Features of H-XL Fire Resistance Test Furnace
- Advanced Thermal Lining & High-Temperature Resistance: Constructed with a baked-enamel steel outer casing and a lightweight high-alumina fiber suspended roof lined with zirconium-fiber wool block modules, ensuring minimal heat loss up to a maximum operating temperature of 1300°C.
- 8-Burner Proportional Gas Combustion System: Fueled by Natural Gas or LPG, the 8-burner array delivers uniform open-flame heating controlled via programmed temperature-rise software according to the standard curve: $T – T_0 = 345 \lg (8t + 1)$.
- Automated Closed-Loop Furnace Pressure Control: Precision pressure sensors located 100mm from the specimen surface dynamically adjust exhaust dampers to maintain constant furnace pressure (15 ± 5 Pa at 5 min, 17 ± 3 Pa at 10 min).
- Computer-Aided Management & Multi-Channel Thermal Monitoring: Fully automated program-driven operation logs real-time unexposed face temperature rises (monitoring mean 140°C and single-point 180°C insulation limits) and structural integrity loss.
- External Specimen Mounting & Rear Exhaust Integration: External specimen fixing layout facilitates rapid loading and unloading of 3m × 3m test frames. The rear mechanical smoke exhaust connects directly to facility dust-removal and scrub systems.
Technical Specifications of Vertical Comprehensive Fire-Resistance Test Furnace
| معايير الاختبار الحاكمة | ايزو 834-1/4/8, في 1363-1, في 1634-1/3, BS 476-20/22, ASTM E119, أول 263, IMO FTP Part 3, جيجابايت/ت 9978, GB 12955-2024 |
| Internal Furnace Chamber Dimensions | 3.0 m (W) × 3.0 m (H) × 1.2 m (D) |
| Overall Equipment Dimensions | 8,000 مم (L) × 6,000 مم (W) × 7,000 مم (H) (Net height: 5,500 مم) |
| Fuel & Burner System | Natural Gas or Liquefied Petroleum Gas (LPG); 8 proportional burners |
| Maximum Operating Temperature | 1300درجة مئوية |
| Furnace Pressure Control | 5 min: 15 Pa ± 5 Pa; 10 min: 17 Pa ± 3 Pa (Measured 100 mm from specimen) |
| Thermal Insulation Criteria | Mean unexposed surface temp rise > 140درجة مئوية, or single-point temp rise > 180درجة مئوية |
| Structural Insulation Material | High-alumina fiber suspended roof & zirconium-fiber wool block-module lining |
| Combustion & Exhaust Control | Automatic curve tracking, proportional gas regulation, computer management, rear mechanical exhaust |
System Architecture & Testing Workflow of H-XL Fire Resistance Test Furnace
سير عمل الاختبار الموحد:
- Mount the vertical specimen (fire door, window, glass partition, roller shutter, or non-return valve) onto the 3m × 3m test frame and position it at the furnace front.
- Attach unexposed face thermocouples to record surface temperature rise and integrity monitoring instruments.
- Initialize the automated program on the PC interface and trigger the 8 gas burners.
- The proportional control system adjusts fuel and air supply to track the standard time-temperature curve $T – T_0 = 345 \lg (8t + 1)$ while maintaining furnace pressure at 15–17 Pa.
- Monitor specimen integrity and insulation failure; upon test termination, automatically extinguish burners, archive test data, and activate rear mechanical smoke exhaust.
تطبيقات العملاء المستهدفة:
- Fire doors, fire windows, glass curtains, and roller shutter manufacturers.
- HVAC check valves, oil-fume exhaust non-return valves, and fire damper production lines.
- Third-party fire protection product inspection bureaus and international certification bodies.
- Civil engineering, architectural safety, and fire research institutes.
H-XL Vertical Comprehensive Fire-Resistance Test Furnace FAQ
س1: What types of specimens can be evaluated using this vertical test furnace?
أ: The H-XL furnace evaluates non-loadbearing and loadbearing vertical separating elements, including fire doors, fire windows, fireproof glass partitions, roller shutters, hollow wall panels, and ventilation/oil-fume exhaust check (non-return) valves.
Q2: How does the furnace control pressure according to GB/T 9978 and EN 1363?
أ: Pressure sensors continuously measure furnace pressure at a 3m height, 100mm from the specimen. The automated PLC system dynamically adjusts the rear mechanical exhaust damper to maintain 15 ± 5 Pa at 5 minutes and 17 ± 3 Pa at 10 minutes.
س3: What indicates a loss of thermal insulation during testing?
أ: Loss of thermal insulation is recorded when either the average temperature rise on the unexposed face of the specimen exceeds 140°C above the initial temperature, or the temperature rise at any single measurement point exceeds 180°C above its initial value.
| Test Parameter | Flame Spread |
|---|---|
| معيار | BS 476, في 1363-1, GB 12955-2024, GB 16809-2024, جيجابايت/ت 23449, جيجابايت/ت 23450, جيجابايت/ت 23451, جيجابايت/ت 38252-2019, جيجابايت/ت 7633, جيجابايت/ت 9978.1, جيجابايت/ت 9978.2, جيجابايت/ت 9978.4, جيجابايت/ت 9978.8, ايزو 834 |