BRT AA1900 flame and graphite furnace AAS with longitudinal furnace heating, titanium burner and eight-lamp turret. Complete technical specifications.

Inquiry Now

EMAIL ADDRESS

FIRST NAME

LAST NAME

whatsapp

MESSAGE

Product overview

The BRT AA1900 integrates flame and graphite furnace atomization in one system. It is built for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis, combining a titanium flame burner with longitudinal graphite furnace heating.

BRT AAS instrument viewed from front left with open sample compartment and autosampler attached
Front-left three-quarter view of the BRT AAS system with the graphite furnace sampler fitted.

Key features across the series

  • Total-reflection optical system designed for high signal-to-noise performance.
  • Eight-lamp turret with 360° rotation and simultaneous preheating of 1–4 lamps.
  • Windows workstation software with automatic control, QA/QC functions, SD/RSD calculation and calibration-curve correlation checking.
  • Multiple data-processing modes including average, peak height, peak area and statistical analysis.
  • One-click database access for wavelength, spectral bandwidth, lamp current, negative high voltage and energy-balance settings.

Optical system and photometric performance

ParameterAA1800AA1900AA2000
Instrument typeFlame systemFlame & GFAA integratedFlame & GFAA integrated
Beam typeDouble-beamDouble-beamDouble-beam
Diffraction grating1800 lines/mm; blaze wavelength 250 nm1800 lines/mm; blaze wavelength 250 nm1800 lines/mm; blaze wavelength 250 nm
Wavelength range185–900 nm185–900 nm185–900 nm
Spectral bandwidth0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Wavelength accuracy±0.15 nm±0.20 nm±0.15 nm
Wavelength repeatability≤0.05 nm≤0.10 nm≤0.05 nm
Spectral bandwidth deviation±0.02 nm±0.02 nm±0.02 nm
Lamp stand8 lamps; simultaneous preheating of 1–4 lamps8 lamps; simultaneous preheating of 1–4 lamps8 lamps; simultaneous preheating of 1–4 lamps
Front view of the BRT AAS with both housings, open sample compartment, cyan tubing and autosampler lid
Straight-on front view of the AAS with both atomization units visible.

Photometric performance

ParameterAA1800AA1900AA2000
Reading modesTransmittance, absorbance, concentrationTransmittance, absorbance, concentrationTransmittance, absorbance, concentration
Photometric range0–125%T; −0.1–3.00 Abs0–125%T; −0.1–3.00 Abs0–125%T; −0.1–3.00 Abs
Baseline stability±0.002 Abs (steady 30 min); ±0.004 Abs (dynamic 15 min)±0.003 Abs (steady 30 min); ±0.005 Abs (dynamic 15 min)±0.002 Abs (steady 30 min); ±0.004 Abs (dynamic 15 min)
Background correctionD₂ lamp ≥40-fold (1 Abs); self-reversal ≥80-fold (1 Abs)D₂ lamp ≥40-fold (1 Abs)D₂ lamp ≥40-fold (1 Abs); self-reversal ≥80-fold (1 Abs)

Flame analysis

ParameterAA1800AA1900AA2000
Characteristic concentration (Cu)≤0.02 μg/mL≤0.035 μg/mL≤0.02 μg/mL
Detection limit (Cu)≤0.004 μg/mL≤0.006 μg/mL≤0.004 μg/mL
Repeatability (Cu)≤0.5%≤0.6%≤0.5%
BurnerTitanium burner headTitanium burner headTitanium burner head
NebulizerHigh-efficiency glass nebulizerHigh-efficiency glass nebulizerHigh-efficiency glass nebulizer
SafetyFlame gas & auxiliary gas abnormal-pressure protectionFlame gas & auxiliary gas abnormal-pressure protectionFlame gas & auxiliary gas abnormal-pressure protection

Graphite furnace analysis

ParameterAA1800AA1900AA2000
Characteristic mass—Cd ≤0.6 pg; Cu ≤20 pgCd ≤0.5 pg; Cu ≤20 pg
Detection limit—Cd ≤1.0 pg; Cu ≤25 pgCd ≤0.8 pg; Cu ≤25 pg
Repeatability (Cd)—≤3%≤2.5%
Temperature range—RT–3000 °CRT–3000 °C
Heating rate—Max. 2000 °C/sMax. 2000 °C/s
Safety—Cooling-water flow, protective-gas pressure, furnace-body temperature, power-supply temperature and graphite-tube installation alarmsCooling-water flow, protective-gas pressure, furnace-body temperature, power-supply temperature and graphite-tube installation alarms

Inside the sample compartment

The graphite furnace workhead, injection assembly and sample bottle sit in the open sample compartment. Longitudinal furnace heating provides uniform gas-phase temperature, rapid atomization and stable analytical performance.

Close-up of graphite furnace workhead, injection assembly and sample bottle inside the BRT AAS sample compartment
Close-up of the graphite furnace workhead and injection assembly inside the sample compartment.

Autosampler and front-panel controls

Close-up of cylindrical autosampler module with matte black lid and vertical Ignition, TurnOff, AutoZero, StartTest buttons
Detail of the autosampler lid and the vertical control buttons.

Data processing

ParameterAA1800AA1900AA2000
Concentration calculationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolationStandard curve (6 linear/non-linear fitting methods), standard addition and interpolation
Repeated measurements1–30 times; average, SD and RSD of absorbance/concentration1–30 times; average, SD and RSD of absorbance/concentration1–30 times; average, SD and RSD of absorbance/concentration

Accessories and physical data

ParameterAA1800AA1900AA2000
Standard accessoriesCu lamp ×1; oil-free air compressor; software; USB flash driveCu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL)Cu lamp ×1; Cd lamp ×1; oil-free air compressor; software; USB flash drive; graphite tube ×5; pipette ×1 (5–50 μL); pipette tips ×1000 (200 μL)
Optional accessoriesOxygen-enriched high-temperature flame; hydride generator; audit-trail software; flame autosamplerOxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosamplerOxygen-enriched high-temperature flame; hydride generator; audit-trail software; recirculating chiller; graphite-furnace autosampler; flame autosampler
Power supplyAC 220 V, 50/60 HzAC 220 V, 50/60 HzAC 220 V, 50/60 Hz
External size (W×D×H)830×650×560 mm830×650×560 mm830×650×560 mm
Package size (W×D×H)1010×780×830 mm1010×780×830 mm1010×780×830 mm
Net weight85 kg120 kg125 kg
Gross weight135 kg183 kg183 kg

Service connections and installation

Close-up of BRT AAS rear panel with cooling louvres, brand plate, mains inlet and gas and water connectors
Detail of the rear panel with power inlet and gas/water connectors.

Rear-panel mains inlet, gas and water connectors are grouped for bench installation. The instrument sits on vibration-isolation feet; unpacking and leveling are required before atomizer alignment.

Frequently asked questions

What elements can this AAS determine?

The series is specified for trace and major element determination in environmental monitoring, food safety testing and metallurgical analysis. Element-specific detection limits are supplied for Cu and Cd in the datasheet; limits for other elements must be confirmed against your application.

What is the wavelength range?

All three models cover 185–900 nm with a 1800 lines/mm grating blazed at 250 nm.

How many lamps can be fitted?

The turret holds eight lamps and can preheat 1–4 lamps simultaneously.

What does the graphite furnace add?

Graphite furnace atomization extends the instrument to lower mass detection limits — the datasheet lists Cd ≤1.0 pg (AA1900) and Cd ≤0.8 pg (AA2000), with a temperature range up to 3000 °C.

Which background correction is fitted?

AA1800 and AA2000 specify D₂ lamp ≥40-fold (1 Abs) and self-reversal ≥80-fold (1 Abs). AA1900 specifies D₂ lamp ≥40-fold (1 Abs).

What data processing is available?

Standard curve with six linear/non-linear fitting methods, standard addition and interpolation; 1–30 repeated measurements with average, SD and RSD.

What power supply is required?

AC 220 V, 50/60 Hz for all three models.

Related models

Compare also: BRT AA1800 BRT AA2000.

See the complete BRT AAS series comparison.

Request a quotation

Specify your element list, sample matrix, required detection limits and atomization mode (flame only or flame + graphite furnace). BRT will confirm the configuration, accessory set and delivery terms. Contact info@brt-test.com or WhatsApp +86 156 0405 7553.

Reviews

There are no reviews yet.

Be the first to review “BRT AA1900 Flame and Graphite Furnace AAS”

Your email address will not be published. Required fields are marked *