BRT-1200UV UV Vis Spectrophotometer is a benchtop single-beam instrument featuring a 200–1000 nm spectral range, 4 nm bandwidth, 1200 lines/mm holographic grating, and ≤0.5 nm wavelength repeatability. Equipped with dual tungsten/deuterium lamps, an LCD display, 9-sample curve fitting, 200-dataset memory, USB PC connectivity, and LPT printer output, it provides precise photometric and quantitative chemical testing.
- UV Vis Spectrophotometer Measurement & Analysis Capabilities
- Technological Features of BRT-1200UV UV Vis Spectrophotometer
- Technical Specifications of UV Vis Spectrophotometer
- Standard Package Accessories Included
- Testing Workflow & Target Applications
- UV Vis Spectrophotometer FAQ
- BRT-1100UV UV Vis Spectrophotometer
- BRT-5900UV UV Vis Spectrophotometer
- BRT-5800UV UV Vis Spectrophotometer
- BRT-5000UV High Precision UV/Vis Spectrophotometer
The BRT-1200UV UV Vis Spectrophotometer is a high-precision benchtop analytical instrument engineered for multi-mode quantitative chemical analysis, optical absorbance screening, and quality control. Designed for environmental monitoring stations, pharmaceutical QA/QC laboratories, biochemical research facilities, and university chemistry departments, it delivers stable spectral performance across the 200 nm to 1000 nm optical spectrum with a 4 nm spectral bandwidth, ±2 nm wavelength accuracy, and ≤0.5 nm wavelength repeatability.
Built with a high-performance single-beam optical system featuring a 1200 lines/mm holographic grating, a high-sensitivity photocell detector, and independently managed tungsten halogen and imported deuterium lamps, this versatile UV Vis Spectrophotometer guarantees superior photometric accuracy (±0.3%T) and reliable quantitative linearity. Equipped with an LCD display, onboard memory for 200 datasets and 9-point linear regression curves, USB connection for PC software, and a parallel printer interface, the BRT-1200UV optimizes routine laboratory testing workflows.
UV Vis Spectrophotometer Measurement & Analysis Capabilities
This benchtop single-beam spectrophotometer enables laboratory operators to conduct certified photometric, quantitative, and kinetic testing routines across liquid and solution samples:
| Analysis Mode | Methodology & Operational Scope | Primary Testing Application |
|---|---|---|
| Photometric Measurement | Direct evaluation of Transmittance (%T) and Absorbance (Abs) at user-specified fixed wavelengths | Routine sample clarity verification, optical density checks, and basic QA transmittance testing |
| Multi-Point Quantitative Curve Fitting | Quantitative concentration profiling using single-point factor method or multi-point calibration fitting up to 9 standard samples with automatic regression calculations | Chemical concentration profiling, pharmaceutical active ingredient quantification, and environmental water pollutant assays |
| PC-Driven Kinetics & Spectral Analysis | Time-course enzyme kinetics, multi-wavelength testing, and full-spectrum scanning via optional professional PC software interface | Enzyme reaction kinetics, thermal degradation monitoring, and complex multi-component sample evaluation |
Technological Features of BRT-1200UV UV Vis Spectrophotometer
- Single-Beam Optics with 1200 L/mm Holographic GratingFeatures an advanced optical path with a 1200 lines/mm holographic grating and silicon photocell detector to deliver sharp optical resolution and high signal purity.
- High Repeatability (≤0.5 nm) & 0.1 nm Resolution DisplayDelivers tight wavelength repeatability (≤0.5 nm) with a 0.1 nm resolution digital readout for consistent baseline stability across repeated measurements.
- Automated Zeroing & Lamp SwitchingIncorporate automatic wavelength positioning, automatic 0A and 100%T calibration, and independent microcomputer control for tungsten and deuterium lamp management.
- Multi-Point Curve Fitting & Onboard MemoryStores up to 200 datasets and regression standard curves generated from up to 9 standard samples directly on the unit without requiring active PC connection.
- Spacious Sample Chamber (5 mm to 100 mm Pathlength)Accommodates cell holders for cuvettes ranging from 5 mm up to 100 mm pathlengths, facilitating both high-concentration and dilute sample analysis.
- Dual Communications Interface (USB & LPT)Equipped with a USB port for bidirectional PC software data management and a parallel port (LPT) for direct printing to dedicated laboratory printers.
Technical Specifications of UV Vis Spectrophotometer
| Product Model | BRT-1200UV Benchtop UV Vis Spectrophotometer |
| Optical System & Grating | Single Beam, 1200 lines/mm Holographic Grating |
| Wavelength Spectrum & Bandwidth | 200 nm to 1000 nm; Spectral Bandwidth: 4 nm; Wavelength Resolution: 0.1 nm |
| Wavelength Accuracy & Repeatability | Accuracy: ±2 nm; Repeatability: ≤0.5 nm |
| Photometric Range & Accuracy | 0 to 200%T, -0.301 to 3.000 Abs, -9999 to 9999 C; Transmittance Accuracy: ±0.3%T |
| Light Sources & Detector | Tungsten Halogen Lamp & Imported Deuterium Lamp; High-Sensitivity Silicon Photocell |
| Data Ports & Storage | USB Interface (PC Software Compatible), LPT Parallel Printer Port; 200 Datasets/Curves Memory |
| Dimensions & Weight | Instrument: 490 × 370 × 180 mm (W × D × H); Total Weight: 14 kg (33.07 lb) |
Standard Package Accessories Included
- Main Host Unit: BRT-1200UV Benchtop UV Vis Spectrophotometer (1 unit).
- Quartz Cuvettes: 10 mm Standard Quartz Cuvettes (2 pcs for Ultraviolet spectrum testing).
- Glass Cuvettes: 10 mm Standard Glass Cuvettes (4 pcs for Visible spectrum testing).
- Sample Cell Holder: Standard Multi-Position Cell Holder.
- Power & Data Cabling: AC Power Cable, USB Interface Connection Cable.
- Documentation & Software: User Operation Manual, Certificate of Quality, Warranty Card.
Testing Workflow & Target Applications
Standardized Testing Workflow:
- Power on the BRT-1200UV; allow the microcomputer system to execute self-testing, light source switching, and baseline initialization.
- Select Photometric or Quantitative mode from the LCD menu interface.
- Load a blank reference solution in the cuvette chamber and initiate automatic 0A / 100%T zeroing.
- Introduce standard samples (up to 9 points) to build a multi-point quantitative calibration curve, or place test samples for immediate concentration readout.
- Save measurement data (up to 200 datasets) to internal memory, stream via USB to PC software, or output directly to a printer via the LPT parallel port.
Target Customer Applications:
- Environmental testing laboratories (COD, heavy metals, nitrate, and phosphate concentration assays).
- Pharmaceutical processing facilities, active pharmaceutical ingredient (API) labs, and life science centers.
- Petrochemical quality control bays, chemical plants, and agriculture/fertilizer testing labs.
- University teaching laboratories, academic research centers, and food & beverage QA labs.
UV Vis Spectrophotometer FAQ
Q1: What is the main difference in performance between wavelength repeatability and accuracy on the BRT-1200UV?
A: Wavelength accuracy (±2 nm) measures how closely the selected wavelength matches the true physical value. Wavelength repeatability (≤0.5 nm) indicates how consistently the instrument returns to the exact same wavelength during repeated tests, ensuring high measurement precision.
Q2: How does multi-point standard curve fitting work on this model?
A: The BRT-1200UV allows users to analyze up to 9 standard sample concentrations directly on the instrument to establish a linear regression equation, display the curve, and automatically calculate unknown sample concentrations.
Q3: Can I run full spectral scanning or kinetics on the BRT-1200UV?
A: Yes. While standalone operation handles photometric and quantitative tests, connecting the instrument to a PC via USB with the optional analysis software enables kinetic tracking and full spectral scanning capabilities.











Reviews
There are no reviews yet.