BRT-1200UV UV Vis Spectrophotometer is a benchtop single-beam instrument featuring a 200–1000 nm spectral range, 4 nm bandwidth, 1200 lines/mm holographic grating, and ≤0.5 nm wavelength repeatability. Equipped with dual tungsten/deuterium lamps, an LCD display, 9-sample curve fitting, 200-dataset memory, USB PC connectivity, and LPT printer output, it provides precise photometric and quantitative chemical testing.

SKU: BRT-1200UV, Categories: ,
Inquiry Now

EMAIL ADDRESS

FIRST NAME

LAST NAME

whatsapp

MESSAGE

The BRT-1200UV UV Vis Spectrophotometer is a high-precision benchtop analytical instrument engineered for multi-mode quantitative chemical analysis, optical absorbance screening, and quality control. Designed for environmental monitoring stations, pharmaceutical QA/QC laboratories, biochemical research facilities, and university chemistry departments, it delivers stable spectral performance across the 200 nm to 1000 nm optical spectrum with a 4 nm spectral bandwidth, ±2 nm wavelength accuracy, and ≤0.5 nm wavelength repeatability.

Built with a high-performance single-beam optical system featuring a 1200 lines/mm holographic grating, a high-sensitivity photocell detector, and independently managed tungsten halogen and imported deuterium lamps, this versatile UV Vis Spectrophotometer guarantees superior photometric accuracy (±0.3%T) and reliable quantitative linearity. Equipped with an LCD display, onboard memory for 200 datasets and 9-point linear regression curves, USB connection for PC software, and a parallel printer interface, the BRT-1200UV optimizes routine laboratory testing workflows.


UV Vis Spectrophotometer Measurement & Analysis Capabilities

This benchtop single-beam spectrophotometer enables laboratory operators to conduct certified photometric, quantitative, and kinetic testing routines across liquid and solution samples:

Analysis Mode Methodology & Operational Scope Primary Testing Application
Photometric Measurement Direct evaluation of Transmittance (%T) and Absorbance (Abs) at user-specified fixed wavelengths Routine sample clarity verification, optical density checks, and basic QA transmittance testing
Multi-Point Quantitative Curve Fitting Quantitative concentration profiling using single-point factor method or multi-point calibration fitting up to 9 standard samples with automatic regression calculations Chemical concentration profiling, pharmaceutical active ingredient quantification, and environmental water pollutant assays
PC-Driven Kinetics & Spectral Analysis Time-course enzyme kinetics, multi-wavelength testing, and full-spectrum scanning via optional professional PC software interface Enzyme reaction kinetics, thermal degradation monitoring, and complex multi-component sample evaluation

Technological Features of BRT-1200UV UV Vis Spectrophotometer

  • Single-Beam Optics with 1200 L/mm Holographic GratingFeatures an advanced optical path with a 1200 lines/mm holographic grating and silicon photocell detector to deliver sharp optical resolution and high signal purity.
  • High Repeatability (≤0.5 nm) & 0.1 nm Resolution DisplayDelivers tight wavelength repeatability (≤0.5 nm) with a 0.1 nm resolution digital readout for consistent baseline stability across repeated measurements.
  • Automated Zeroing & Lamp SwitchingIncorporate automatic wavelength positioning, automatic 0A and 100%T calibration, and independent microcomputer control for tungsten and deuterium lamp management.
  • Multi-Point Curve Fitting & Onboard MemoryStores up to 200 datasets and regression standard curves generated from up to 9 standard samples directly on the unit without requiring active PC connection.
  • Spacious Sample Chamber (5 mm to 100 mm Pathlength)Accommodates cell holders for cuvettes ranging from 5 mm up to 100 mm pathlengths, facilitating both high-concentration and dilute sample analysis.
  • Dual Communications Interface (USB & LPT)Equipped with a USB port for bidirectional PC software data management and a parallel port (LPT) for direct printing to dedicated laboratory printers.

Technical Specifications of UV Vis Spectrophotometer

Product Model BRT-1200UV Benchtop UV Vis Spectrophotometer
Optical System & Grating Single Beam, 1200 lines/mm Holographic Grating
Wavelength Spectrum & Bandwidth 200 nm to 1000 nm; Spectral Bandwidth: 4 nm; Wavelength Resolution: 0.1 nm
Wavelength Accuracy & Repeatability Accuracy: ±2 nm; Repeatability: ≤0.5 nm
Photometric Range & Accuracy 0 to 200%T, -0.301 to 3.000 Abs, -9999 to 9999 C; Transmittance Accuracy: ±0.3%T
Light Sources & Detector Tungsten Halogen Lamp & Imported Deuterium Lamp; High-Sensitivity Silicon Photocell
Data Ports & Storage USB Interface (PC Software Compatible), LPT Parallel Printer Port; 200 Datasets/Curves Memory
Dimensions & Weight Instrument: 490 × 370 × 180 mm (W × D × H); Total Weight: 14 kg (33.07 lb)

Standard Package Accessories Included

  • Main Host Unit: BRT-1200UV Benchtop UV Vis Spectrophotometer (1 unit).
  • Quartz Cuvettes: 10 mm Standard Quartz Cuvettes (2 pcs for Ultraviolet spectrum testing).
  • Glass Cuvettes: 10 mm Standard Glass Cuvettes (4 pcs for Visible spectrum testing).
  • Sample Cell Holder: Standard Multi-Position Cell Holder.
  • Power & Data Cabling: AC Power Cable, USB Interface Connection Cable.
  • Documentation & Software: User Operation Manual, Certificate of Quality, Warranty Card.

Testing Workflow & Target Applications

Standardized Testing Workflow:

  1. Power on the BRT-1200UV; allow the microcomputer system to execute self-testing, light source switching, and baseline initialization.
  2. Select Photometric or Quantitative mode from the LCD menu interface.
  3. Load a blank reference solution in the cuvette chamber and initiate automatic 0A / 100%T zeroing.
  4. Introduce standard samples (up to 9 points) to build a multi-point quantitative calibration curve, or place test samples for immediate concentration readout.
  5. Save measurement data (up to 200 datasets) to internal memory, stream via USB to PC software, or output directly to a printer via the LPT parallel port.

Target Customer Applications:

  • Environmental testing laboratories (COD, heavy metals, nitrate, and phosphate concentration assays).
  • Pharmaceutical processing facilities, active pharmaceutical ingredient (API) labs, and life science centers.
  • Petrochemical quality control bays, chemical plants, and agriculture/fertilizer testing labs.
  • University teaching laboratories, academic research centers, and food & beverage QA labs.

UV Vis Spectrophotometer FAQ

Q1: What is the main difference in performance between wavelength repeatability and accuracy on the BRT-1200UV?

A: Wavelength accuracy (±2 nm) measures how closely the selected wavelength matches the true physical value. Wavelength repeatability (≤0.5 nm) indicates how consistently the instrument returns to the exact same wavelength during repeated tests, ensuring high measurement precision.

Q2: How does multi-point standard curve fitting work on this model?

A: The BRT-1200UV allows users to analyze up to 9 standard sample concentrations directly on the instrument to establish a linear regression equation, display the curve, and automatically calculate unknown sample concentrations.

Q3: Can I run full spectral scanning or kinetics on the BRT-1200UV?

A: Yes. While standalone operation handles photometric and quantitative tests, connecting the instrument to a PC via USB with the optional analysis software enables kinetic tracking and full spectral scanning capabilities.

Reviews

There are no reviews yet.

Be the first to review “BRT-1200UV UV Vis Spectrophotometer”

Your email address will not be published. Required fields are marked *