BRT-5200UV UV Vis Spectrophotometer is a 15 kg benchtop C-T monochromator instrument featuring a 190–1100 nm spectral range, 2 nm bandwidth, 1200 lines/mm grating, and silicon photocell detector. Equipped with dual tungsten/deuterium lamps, real-time baseline monitoring, LCD screen, 200-dataset memory, USB PC connectivity, and LPT printer output, it provides precise photometric and quantitative chemical analysis.

SKU: BRT-5200UV, Categories: ,
Inquiry Now

EMAIL ADDRESS

FIRST NAME

LAST NAME

whatsapp

MESSAGE

The BRT-5200UV UV Vis Spectrophotometer is a high-precision benchtop analytical instrument engineered around a classic Czerny-Turner (C-T) monochromator optical architecture and a high-sensitivity silicon photocell detector. Designed for industrial QA/QC labs, pharmaceutical research centers, chemical testing facilities, and environmental testing agencies, it delivers superior baseline stability and high optical purity across the 190 nm to 1100 nm spectral range with a 2 nm spectral bandwidth, ±1 nm wavelength accuracy, and ≤0.5 nm wavelength repeatability.

Built with dual light sources—featuring an imported deuterium lamp for ultraviolet coverage and a tungsten halogen lamp for visible spectrum analysis—this versatile UV Vis Spectrophotometer guarantees reliable transmittance accuracy (±0.3%T) and low baseline drift. Equipped with a large dot-matrix LCD screen, onboard memory for 200 datasets and calibration curves, automated zeroing, real-time baseline monitoring, and high-speed USB PC software connectivity, the 15 kg BRT-5200UV provides a stable platform for routine concentration and photometric testing.


UV Vis Spectrophotometer Measurement & Analysis Capabilities

This C-T monochromator spectrophotometer equips laboratory operators to perform routine photometric, quantitative, and kinetic testing workflows across liquid and solution samples:

Analysis Mode Methodology & Operational Scope Primary Testing Application
Photometric Measurement Direct determination of Absorbance (Abs) and Transmittance (%T) at user-selected fixed wavelengths across 190–1100 nm Routine sample clarity screening, optical density checks, and basic QA/QC transmittance testing
Quantitative Concentration Profiling Concentration determinations via standard coefficient method ($C = KA + B$) or multi-point standard sample curve fitting with automatic regression calculations Chemical solution concentration assays, environmental water pollutant checks (COD, nitrate, heavy metals), and active ingredient analysis
PC-Driven Kinetics & Spectral Analysis Time-course kinetics tracking, dynamic reaction rates, and multi-wavelength testing using optional professional PC software via USB connection Enzymatic reaction rates, dynamic degradation monitoring, and complex multi-component chemical evaluation

Technological Features of BRT-5200UV UV Vis Spectrophotometer

  • C-T Monochromator Optics & Silicon Photocell Detector

    Engineered with a high-performance Czerny-Turner monochromator containing a 1200 lines/mm holographic grating and a silicon photocell detector for high optical linearity and minimal stray light.

  • Dual Light Source System with Independent Control

    Combines an imported deuterium lamp and a tungsten halogen lamp with automated microcomputer switching and independent lamp control to optimize light source longevity.

  • Real-Time Baseline Monitoring & Auto Zero Calibration

    Features active baseline drift monitoring to preserve optical accuracy during extended testing, backed by automated 0A and 100%T baseline calibration.

  • 2 nm Spectral Bandwidth & 0.1 nm Display Resolution

    Delivers a tight 2 nm optical bandwidth across 190–1100 nm with 0.1 nm readout resolution, ensuring high repeatability (≤0.5 nm) for accurate absorption measurement.

  • Spacious Sample Chamber (5 mm to 100 mm Pathlength)

    Accommodates cell holders for cuvettes ranging from 5 mm up to 100 mm pathlengths, making it suitable for both concentrated biological samples and dilute environmental solutions.

  • Dual Output Ports (USB Interface & LPT Parallel Port)

    Equipped with a USB port for streaming data to PC analysis software and an LPT parallel port for direct printing to dedicated laboratory printers.


Technical Specifications of UV Vis Spectrophotometer

Product Model BRT-5200UV C-T Monochromator UV Vis Spectrophotometer
Optical System & Grating Single Beam C-T Monochromator, 1200 lines/mm Holographic Grating
Wavelength Spectrum & Bandwidth 190 nm to 1100 nm; Spectral Bandwidth: 2 nm; Wavelength Resolution: 0.1 nm
Wavelength Accuracy & Repeatability Accuracy: ±1 nm; Repeatability: ≤0.5 nm
Photometric Range & Accuracy 0 to 200%T, -0.301 to 3.000 Abs, -9999 to 9999 C; Transmittance Accuracy: ±0.3%T
Light Sources & Detector Tungsten Halogen Lamp & Imported Deuterium Lamp; Silicon Photocell Detector
Data Output & Memory Storage Stores 200 Datasets & Standard Curves; USB PC Interface, LPT Parallel Printer Port
Dimensions & Instrument Weight 470 × 380 × 225 mm (W × D × H); Total Weight: 15 kg (33.07 lb)

Standard Package Accessories Included

  • Main Host Unit: BRT-5200UV UV Vis Spectrophotometer (1 unit).
  • Quartz Cuvettes: 10 mm Standard Quartz Cuvettes (2 pcs for Ultraviolet spectrum testing).
  • Glass Cuvettes: 10 mm Standard Glass Cuvettes (4 pcs for Visible spectrum testing).
  • Sample Cell Holder: Standard Multi-Position Cell Holder.
  • Power & PC Connectivity: AC Power Cable, USB Interface Cable.
  • Documentation & Software: Operating Manual, Quality Certificate, Warranty Card.

Testing Workflow & Target Applications

Standardized Testing Workflow:

  1. Power on the BRT-5200UV; allow the system to execute dark current zeroing, lamp power check, and wavelength self-calibration.
  2. Select Photometric or Quantitative mode from the large LCD screen menu.
  3. Place a reference solvent blank into the cell holder and initiate auto 0A / 100%T baseline zeroing.
  4. Introduce standard samples to build a quantitative curve (or input coefficient K and offset B), then analyze test samples for direct concentration readouts.
  5. Store measurement datasets (up to 200 sets) directly to onboard memory, transmit via USB to optional PC software, or output reports via the LPT parallel printer port.

Target Customer Applications:

  • Chemical processing facilities, petrochemical inspection bays, and raw material quality assurance.
  • Pharmaceutical manufacturing labs, active pharmaceutical ingredient (API) assay centers, and life science labs.
  • Environmental water testing laboratories (nitrate, phosphate, heavy metal, and COD assays).
  • Academic chemistry labs, university research centers, and food safety inspection stations.

UV Vis Spectrophotometer FAQ

Q1: What is the significance of the C-T monochromator in the BRT-5200UV?

A: The Czerny-Turner (C-T) monochromator design uses dedicated optical elements to route light precisely through the 1200 lines/mm grating. This minimizes optical aberrations and stray light, resulting in a stable baseline and higher measurement accuracy.

Q2: How does real-time baseline monitoring benefit laboratory analysis?

A: Real-time baseline monitoring continuously tracks system performance and optical drift, ensuring that long analytical sequences maintain precise baseline integrity without requiring constant manual zeroing.

Q3: What analytical capabilities are unlocked by connecting optional PC software via USB?

A: While onboard functions handle direct photometric and quantitative concentration testing, connecting the instrument to PC software via USB enables time-course kinetic measurements, multi-wavelength testing, and spectral analysis.

Reviews