GTL-50 Steel Structure Fire Retardant Coating Sample Test Furnace strictly meets ايزو 834, BS 476 (Parts 20/21), في 13381-4/8, ASTM E119, أول 263, و GB 14907-2018 المعايير. Features touch screen & wireless PC dual control, diesel spray heating up to 1210°C / 360 min, constant 20±3Pa furnace pressure control, auto thermocouple fault elimination, and automatic curve logging for steel coating fire resistance evaluation.

رمز التخزين التعريفي: GTL-50, فئات: ,
الاستفسار الآن

عنوان البريد الإلكتروني

الاسم الأول

اسم العائلة

واتس اب

رسالة

ال GTL-50 Steel Structure Fire Retardant Coating Sample Test Furnace is a dedicated laboratory testing instrument developed strictly in accordance with ايزو 834, BS 476 (Parts 20/21), في 13381-4/8, ASTM E119, أول 263, و GB 14907-2018 المعايير. It is engineered to evaluate the fire resistance rating, thermal insulation efficiency, and flame retardancy of fireproof coatings applied to steel plates and structural components.

Featuring a compact 1.6m × 1.6m × 1.6m diesel-fueled heating chamber, dual touch screen and wireless PC control, real-time closed-loop temperature and pressure curve tracking (up to 1210°C / 360 min), and automatic thermocouple fault elimination, this high-precision Fire-Retardant Coating Thermal Insulation Efficiency Test Furnace delivers authoritative test data for paint manufacturers, third-party fire testing laboratories, marine classification bodies, and construction material quality supervision bureaus.


Steel Structure Fire Retardant Coating Sample Test Furnace Compliance & المعايير

This fire-retardant coating sample test furnace enables certified testing facilities to assess coating performance across global structural fire protection frameworks:

الكود القياسي العنوان القياسي & نِطَاق Testing Application
ايزو 834 / BS 476-20/21 Fire-resistance tests — Elements of building construction & loadbearing structural elements International benchmark for standard time-temperature fire curve compliance and coating testing
في 13381-8 / في 13381-4 Test methods for determining the contribution to the fire resistance of structural members (Reactive & Passive protection to steel) European standard for intumescent (reactive) and thick non-intumescent (passive) steel fireproof coatings
ASTM E119 / أول 263 Standard Test Methods for Fire Tests of Building Construction and Materials North American fire resistance and thermal insulation evaluations for structural steel coatings
GB 14907-2018 & جيجابايت/ت 9978-2008 Fire-retardant coating for steel structures & Fire-resistance tests for building elements Mandatory Chinese national standard for thermal insulation efficiency & fire resistance limit testing
IMO FTP Code Part 11 International Code for Application of Fire Test Procedures — Structural Fire Protection Fire protection coating evaluations for marine steel structures, deck bulkheads, and offshore platforms

Technological Features of GTL-50 Fire-Retardant Coating Test Furnace

  • Dual Touch Screen & Wireless PC Multi-Station Linkage: Operates via an intuitive standalone onboard touch screen or wireless PC software. Supports multi-furnace synchronization from a single computer terminal and allows centralized data monitoring across network workstations.
  • High-Efficiency Diesel Spray Burner & Standard Curve Simulation: Equipped with an automatic diesel combustion system (using 0# / -10# diesel fuel) capable of following standard time-temperature curves up to 1210°C over a 360-minute duration (على سبيل المثال, 60 min @ 925°C, 180 min @ 1115°C, 360 min @ 1210°C).
  • Automated Closed-Loop Pressure & Temperature Regulation: Maintains a constant furnace pressure of 20 ± 3 Pa (0–100 Pa measurement range) and a tight unexposed surface temperature tolerance within ±4°C, vastly surpassing national standard precision thresholds.
  • Intelligent Thermocouple Fault Elimination & Flame Protection: Built-in self-diagnostics automatically detect, isolate, and shield damaged thermocouple signals during continuous heating. Features automatic re-ignition protection in the event of accidental flameout during testing.
  • Automated Post-Test Exhaust Cooling & Power-Off Protection: Includes forced exhaust heat dissipation upon test completion to accelerate turn-around times. Built-in power-off backup programs prevent data loss and equipment damage during sudden electrical interruptions.

Technical Specifications of Steel Structure Fire Retardant Coating Test Furnace

معايير الاختبار الحاكمة ايزو 834, BS 476-20/21, في 13381-4/8, ASTM E119, أول 263, GB 14907-2018, جيجابايت/ت 9978-2008, IMO FTP Code Part 11
Standard Specimen Dimensions 500 مم × 500 مم × 6 مم (Coated steel plate)
Heating Fuel & System 0# / -10# Diesel; full-automatic spray burner assembly
Programmed Temperature Curves 60 min: 925درجة مئوية | 120 min: 1050درجة مئوية | 180 min: 1115درجة مئوية | 240 min: 1150درجة مئوية | 300 min: 1180درجة مئوية | 360 min: 1210درجة مئوية
Furnace & Surface Thermocouples 4 furnace sensors + 2 unexposed surface sensors (Class II K-type sheathed); Tolerance: ±4°C
Furnace Pressure Control Range: 0–100 Pa; Closed-loop constant control: 20 ± 3 Pa
Airflow Volume & دقة 0–50 m³/min; Measurement accuracy: ≤ ±0.5 m³/min
Timer & Data Storage Timing range: 0–360 min (< ±2s accuracy); Onboard memory stores >100 test groups
مزود الطاقة & Consumption AC 220V ±10%, 50 هرتز; Total Power: 3.0 كيلوواط
Overall Equipment Dimensions 1.6 m (L) × 1.6 m (W) × 1.6 m (H)

System Architecture & Testing Workflow of Fire Retardant Coating Test Furnace

سير عمل الاختبار الموحد:

  1. Apply the steel structure fire-retardant coating to the 500mm × 500mm × 6mm standard steel plate specimen and allow it to cure per standard instructions.
  2. Mount the specimen onto the test furnace opening, attaching K-type thermocouples to the unexposed face to measure heat conduction.
  3. Select the target fire-resistance duration (على سبيل المثال, 180 or 360 minutes) on the touch screen or wireless PC interface.
  4. Trigger the automatic spray burner; the system heats up following the GB 14907 / ايزو 834 curve while continuously recording furnace pressure and unexposed surface temperature.
  5. Upon test completion, the furnace automatically terminates heating, saves test records, and initiates forced exhaust cooling.

تطبيقات العملاء المستهدفة:

  • Thin, ultra-thin, and thick steel structure fireproof coating manufacturers.
  • Third-party fire protection product inspection centers and construction quality laboratories.
  • Chemical engineering and polymer R&D institutes specializing in intumescent flame-retardant coatings.
  • University civil engineering and fire safety science research centers.

Steel Structure Fire Retardant Coating Sample Test Furnace FAQ

س1: What is the main evaluation metric for GB 14907 steel structure coating tests?

أ: The primary metric is the Thermal Insulation Efficiency / Fire Resistance Limit, defined as the time required for the average temperature of the unexposed steel plate to reach a critical limit (typically 500°C or specified temperature rise) under the standard fire time-temperature curve.

Q2: How does the wireless PC control benefit multi-furnace laboratory operations?

أ: Wireless linkage enables a single central computer terminal to wirelessly connect to and synchronously control multiple GTL-50 test furnaces. Laboratories can execute simultaneous batch tests, collect live data, and archive reports without extensive cabling.

س3: What safety mechanisms are built into the diesel combustion system?

أ: The GTL-50 includes automatic flameout detection with auto re-ignition capabilities, power-off memory protection, and over-temperature safety cut-offs to guarantee safe, unattended laboratory testing.

Test Parameter

Flame Spread

معيار

BS 476, GB 14907-2018, جيجابايت/ت 9978-2008, ايزو 834

التعليقات

لا توجد تعليقات حتى الآن.

كن أول من يقيم “GTL-50 Steel Structure Fire Retardant Coating Sample Test Furnace”